Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chips”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Preliminary Radiation Testing of a State-of-the-Art Commercial 14nm CMOS Processor - System-on-a-Chip

Hardness assurance test results of Intel state-of-the-art 14nm Broadwell U-series processor System-on-a-Chip (SoC) for total dose are presented, along with first-look exploratory results from trials at a medical proton facility. Test method builds upon previous efforts by utilizing commercial laptop motherboards and software stress applications as opposed to more traditional automated test equipment (ATE).

14nm↗

Lab-On-Chip Clinorotation System for Live-Cell Microscopy Under Simulated Microgravity

Cells in microgravity are subject to mechanical unloading and changes to the surrounding chemical environment. How these factors jointly influence cellular function is not well understood. We can investigate their role using ground-based analogues to spaceflight, where mechanical unloading is simulated through the time-averaged nullification of gravity. The prevailing method for cellular microgravity simulation is to use fluid-filled containers called clinostats. However, conventional clinostats are not designed for temporally tracking cell response, nor are they able to establish dynamic fluid environments. To address these needs, we developed a Clinorotation Time-lapse Microscopy (CTM) system that accommodates lab-on- chip cell culture devices for visualizing time-dependent alterations to cellular behavior. For the purpose of demonstrating CTM, we present preliminary results showing time-dependent differences in cell area between human mesenchymal stem cells (hMSCs) under modeled microgravity and normal gravity.

Yew, Alvin G.↗

Chip Scale Ultra-Stable Clocks: Miniaturized Phonon Trap Timing Units for PNT of CubeSats

The Chip Scale Ultra-Stable Clocks (CSUSC) project aims to provide a superior alternative to current solutions for low size, weight, and power timing devices. Currently available quartz-based clocks have problems adjusting to the high temperature and extreme acceleration found in space applications, especially when scaled down to match small spacecraft size, weight, and power requirements. The CSUSC project aims to utilize dual-mode resonators on an ovenized platform to achieve the exceptional temperature stability required for these systems. The dual-mode architecture utilizes a temperature sensitive and temperature stable mode simultaneously driven on the same device volume to eliminate ovenization error while maintaining extremely high performance. Using this technology it is possible to achieve parts-per-billion (ppb) levels of temperature stability with multiple orders of magnitude smaller size, weight, and power.

Dual-mode resonators↗

Degradation and ESR Failures in MnO2 Chip Tantalum Capacitors

Equivalent series resistance (ESR) of chip tantalum capacitors determines the rate of energy delivery and power dissipation thus affecting temperature and reliability of the parts. Employment of advanced capacitors with reduced ESR decreases power losses and improves efficiency in power systems. Stability of ESR is essential for correct operations of power units and might cause malfunctioning and failures when ESR becomes too high or too low. Several cases with ESR values in CWR29 capacitors exceeding the specified limit that were observed recently raised concerns regarding environmental factors affecting ESR and the adequacy of the existing screening and qualification testing. In this work, results of stress testing of various types of military and commercial capacitors obtained over years by GSFC test lab and NEPP projects that involved ESR measurements are described. Environmental stress tests include testing in humidity and vacuum chambers, temperature cycling, long-term storage at high temperatures, and various soldering simulation tests. Note that in many cases parts failed due to excessive leakage currents or reduced breakdown voltages. However, only ESR-related degradation and failures are discussed. Mechanisms of moisture effect are discussed and recommendations to improve screening and qualification system are suggested.

Equivalent Series Resistance (ESR)↗

Low-Power, Chip-Scale, Carbon Dioxide Gas Sensors for Spacesuit Monitoring

N5 Sensors, Inc. through a Small Business Technology Transfer (STTR) contract award has been developing ultra-small, low-power carbon dioxide (CO2) gas sensors, suited for monitoring CO2 levels inside NASA spacesuits. Due to the unique environmental conditions within the spacesuits, such as high humidity, large temperature swings, and operating pressure swings, measurement of key gases relevant to astronaut's safety and health such as(CO2), is quite challenging. Conventional non-dispersive infrared absorption based CO2 sensors present challenges inside the spacesuits due to size, weight, and power constraints, along with the ability to sense CO2 in a high humidity environment. Unique chip-scale, nanoengineered chemiresistive gas-sensing architecture has been developed for this application, which can be operated in a typical space-suite environmental conditions. Unique design combining the selective adsorption properties of the nanophotocatalytic clusters of metal-oxides and metals, provides selective detection of CO2 in high relative humidity conditions. All electronic design provides a compact and low-power solution, which can be implemented for multipoint detection of CO2 inside the spacesuits. This paper will describe the sensor architecture, development of new photocatalytic material for better sensor response, and advanced structure for better sensitivity and shorter response times.

Rani, Asha↗

Interconnection of Semiconductor Devices in Extreme Environment Microelectronic Integrated Circuit Chips

A process of fabrication and the resulting integrated circuit device is made of patterned metal electrical interconnections between semiconductor devices residing on and forming extremely harsh environment integrated circuit chips. The process enables more complicated wide band gap semiconductor integrated circuits with more than one level of interconnect to function for prolonged time periods (over 1000 hours) at much higher temperatures (500 C).

Spry, David J.↗

Second-Generation Design of Micro-Spec: A Medium-Resolution, Submillimeter-Wavelength Spectrometer-on-a-Chip

Micro-Spec (μ-Spec) is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ∼10-cm2 chip through the use of superconducting microstrip transmission lines on a single-crystal silicon substrate. A second-generation μ-Spec is being designed to operate with a spectral resolution of 512 in the submillimeter (500-1000 μm, 300-600 GHz) wavelength range, a band of interest for several spectroscopic applications in astrophysics. High altitude balloon missions would provide the first test bed to demonstrate the μ-Spec technology in a space-like environment and would be an economically viable venue for multiple observation campaigns. This work reports on the current status of the instrument design and will provide a brief overview of each instrument subsystem. Particular emphasis will be given to the design of the spectrometer's two-dimensional diffractive region, through which the light of different wavelengths is focused on the detectors along the focal plane. An optimization process is employed to generate geometrical configurations of the diffractive region that satisfy specific requirements on spectrometer size, operating spectral range, and performance. An optical design optimized for balloon missions will be presented in terms of geometric layout, spectral purity, and efficiency.

Cataldo, G.↗

Low-Power, Chip-Scale, CO2 Gas Sensors for Spacesuit Monitoring

N5 Sensors, Inc. and NASA through a STTR program are jointly developing ultra-small, low-power carbon dioxide (CO2) gas sensors, suited for monitoring CO2 levels inside the spacesuits. Due to the unique environmental conditions within the spacesuits, such as high humidity, large temperature and operating pressure swings, measurement of key gases relevant to astronaut's safety and health such as carbon dioxide, is quite challenging. Conventional non-dispersive infrared absorption based CO2 sensors cannot be effectively implemented inside the spacesuits due to their sizes, weights, and power constraints. Metal-oxide based sensors have been effectively miniaturized for several applications, however detection of CO2 utilizing metal-oxide based sensors is challenging due to the chemical inertness and high stability of CO2 at room-temperatures. To mitigate these limitations, unique chip-scale, nanoengineered chemiresistive gas-sensing architecture has been developed - to allow the Metal-oxide sensors to operate in space-suite environmental conditions. Unique design combining the selective adsorption properties of the nanophotocatalytic clusters of metal-oxides and metals, provides selective detection of CO2 in high relative humidity conditions. All electronic design provides a compact and low-power solution, which can be implemented for multipoint detection of CO2 inside the spacesuits. This paper will describe a novel approach in refining the sensor architecture, development of new photocatalytic material for better sensor performance.

Thomson, Brian↗

Developing High-Throughput Organ-On-A-Chip Models to Investigate the Effects of Ionizing Radiation on the Central Nervous System

One of the main health risks in human space exploration is central nervous system (CNS) damage by ionizing radiation. Irradiation with simulated GCRs or their components, or high doses of low-LET radiation such as gamma rays, in animal models has been shown to cause neuronal damage together with glial cell activation and neuroinflammation and has been associated with prolonged cognitive and behavioral dysfunction. The extent of CNS damage in response to any insult, including ionizing radiation, is partially regulated by the blood-brain barrier (BBB), which enables immune cells to enter the CNS. The main cellular regulators of BBB permeability are astrocytes, which also modulate neuronal death, immune responses and oxidative stress, and thus could serve as a robust CNS-specific target for countermeasure development. However, studies on BBB permeability and astrocyte functions in regulating CNS responses to ionizing radiation have been limited, especially in human tissue/organ analogs. Therefore, we have established a high throughput 3D organ-on-a-chip system to study human CNS functions in response to ionizing radiation, with the eventual goal of adapting it to spaceflight missions. We utilized commercially available OrganoPlate system (Mimetas, Inc.) seeded with primary or induced pluripotent stem cell-derived human cells for developing 3D neuronal-astrocytic and BBB models. We investigated both immediate and delayed CNS dose responses to 0.5-1 Gy X-rays by measuring BBB permeability and morphology, and astrocyte activation. We have also quantified secreted markers of oxidative stress and cell viability. In the future, we are planning to monitor dendritic, axonal and synaptic changes in neurons, evaluate the combined exposures to simulated microgravity and ionizing radiation, and compare the responses to low and high-LET ionizing radiation. We anticipate these studies could indicate novel cellular and mechanistic targets for countermeasure developments to improve CNS functions in astronauts.

Malkani, Sherina↗

Sensor Chip Assembly (SCA) Test Report

This report summarizes the measured performance for the Sensor Chip Assembly (SCA), which is identified in Table 1. The SCA architecture is a substrate-removed HgCdTe detector with an area of 4096x4096 pixels (with a reference pixel area of four pixels deep around all four sides, available to substitute corresponding image pixels) and a pixel pitch of 10 μm. This SCA has been tested at the Goddard Space Flight Center (GSFC/NASA) Detector Characterization Laboratory (DCL). Teledyne (the vendor) classifies its detectors into different grades based on testing performed at its facility. The classification of this SCA and the tested dates are included in Table 1 below. The tests performed on this array are derived from the document WFIRST-PROC-09220_WFIRST-SCA-ATP_-.docx. A summary of the test parameters, requirements, and test results is presented in Table 2. The details of each test are subsequently described in the report. In the Summary (Table 2), SCA results are reported at an operating temperature of 95K, and 1.0 V bias voltage. In the detailed section of each test, the results for 90 K (1.0V bias voltage) and 95 K (0.5V bias voltage) are also reported. For all cases, the frame time used is 2.764 seconds. Reference pixel correction was applied to every raw frame.

WFIRST SCA TEST REPORT↗

Monitoring Biomarkers for Muscular Atrophy Using an Electrochemical Chip for Astronaut Space Health

Skeletal muscle atrophy is a serious health problem for astronauts in long-duration space flight under microgravity conditions. Preventative measures against muscle atrophy require specific exercise and dietary regimens. Preemptive measurements to improve treatment have the potential to streamline these regimens, decreasing their daily footprint and increasing astronaut quality of life. The objective of our proposed project is to (1) develop a fully integrated disposable microelectrode array chip (with the size of a stamp) that can be interfaced with a handheld electronic system for simultaneous detection of the a panel of biomarkers to monitor the progression of skeletal muscle atrophy due to disuse under microgravity in long-duration spaceflights; and (2) use such quantitative information to guide the combined countermeasures of physical exercise and pharmaceuticals (i.e. specific protease inhibitors) so that the intensity, duration and frequency of exercise can be reduced. Note: The presentation includes voice commentary and plays best as a slide show. The voice begins once the presentation starts, and only requires the user to click to the next slide each time. With a run time of ~15 mins.

Biosensor↗

Monitoring Biomarkers for Muscular Atrophy using an Electronic Chip for Astronaut Health

Skeletal muscle atrophy is a serious health problem for astronauts in long-duration space flight under microgravity conditions. Preventative measures against muscle atrophy require specific exercise and dietary regimens. Preemptive measurements to improve treatment have the potential to streamline these regimens, decreasing their daily footprint and increasing astronaut quality of life. The objective of our proposed project is to (1) develop a fully integrated disposable microelectrode array chip (with the size of a stamp) that can be interfaced with a handheld electronic system for simultaneous detection of the a panel of biomarkers to monitor the progression of skeletal muscle atrophy due to disuse under microgravity in long-duration spaceflights; and (2) use such quantitative information to guide the combined countermeasures of physical exercise and pharmaceuticals (i.e. specific protease inhibitors) so that the intensity, duration and frequency of exercise can be reduced.

Biosensing↗

Chip Scale Package Integrity Assessment by Isothermal Aging

Many aspects of chip scale package (CSP) technology, with focus on assembly reliability characteristics, are being investigated by the JPL-led consortia. Three types of test vehicles were considered for evaluation and currently two configurations have been built to optimize attachment processes.

chipscale↗

Chip Scale Package Implementation Challenges

The JPL-led MicrotypBGA Consortium of enterprises representing government agencies and private companies have joined together to pool in-kind resources for developing the quality and reliability of chip scale packages (CSPs) for a variety of projects.

chipscale↗

On-Chip p-MOSFET Dosimetry

On-chip p-FETs were developed to monitor the radiation dose of n-well CMOS ICs by monitoring threshold voltage shifts due to radiation induced oxide and interface charge.

FETs↗

Catastrophic fault recovery with self-reconfigurable chips

Mission critical systems typically employ multi-string redundancy to cope with possible hardware failure. Such systems are only as fault tolerant as there are many redundant strings. Once a particular critical component exhausts its redundant spares, the multi-string architecture cannot tolerate any further hardware failure. This paper aims at addressing such catastrophic faults through the use of "Self-Reconfigurable Chips" as a last resort effort to "repair" a faulty critical component.

Chau, Savio N.↗