Search NASASearch

SEARCH · Search NASA

Results for “state of charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3,246 records · Page 16

Cation valency in water-in-salt electrolytes alters the short- and long-range structure of the electrical double layer

Highly concentrated aqueous electrolytes (termed water-in-salt electrolytes, WiSEs) at solid-liquid interfaces are ubiquitous in myriad applications including biological signaling, electrosynthesis, and energy storage. This interface, known as the electrical double layer (EDL), has a different structure in WiSEs than in dilute electrolytes. Here, we investigate how divalent salts [zinc bis(trifluoromethylsulfonyl)imide, Zn(TFSI) 2 ], as well as mixtures of mono- and divalent salts [lithium bis(trifluoromethylsulfonyl)imide (LiTFSI) mixed with Zn(TFSI) 2 ], affect the short- and long-range structure of the EDL under confinement using a multimodal combination of scattering, spectroscopy, and surface forces measurements. Raman spectroscopy of bulk electrolytes suggests that the cation is closely associated with the anion regardless of valency. Wide-angle X-ray scattering reveals that all bulk electrolytes form ion clusters; however, the clusters are suppressed with increasing concentration of the divalent ion. To probe the EDL under confinement, we use a Surface Forces Apparatus and demonstrate that the thickness of the adsorbed layer of ions at the interface grows with increasing divalent ion concentration. Multiple interfacial layers form following this adlayer; their thicknesses appear dependent on anion size, rather than cation. Importantly, all electrolytes exhibit very long electrostatic decay lengths that are insensitive to valency. It is likely that in the WiSE regime, electrostatic screening is mediated by the formation of ion clusters rather than individual well-solvated ions. This work contributes to understanding the structure and charge-neutralization mechanism in this class of electrolytes and the interfacial behavior of mixed-electrolyte systems encountered in electrochemistry and biology.

Science & Technology - Other Topics

Symmetry‐Breaking Strategy Yields Dopant‐Free Small Molecule Hole Transport Materials for Inorganic Perovskite Solar Cells with 20.58% Efficiency and Outstanding Stability

Abstract Inorganic perovskites are known for their excellent photothermal stability; however, the photothermal stability of all‐inorganic n‐i‐p perovskite solar cells (PSCs) is compromised due to ion diffusion and free radical‐induced degradation caused by the use of doped spiro‐OMeTAD hole transport materials (HTMs). In this study, two isomeric donor–acceptor–donor (D–A–D) type small molecules, namely HBT and HiBT, were developed and used as dopant‐free HTMs, using 2,1,3‐benzothiadiazole or benzo[d][1,2,3]thiadiazole as acceptor moieties. The HiBT molecule, with its symmetry‐breaking features, exhibits a large dipole moment, enhanced coordination‐active sites, and a well‐aligned energy level structure, all of which contribute to passivating perovskite surface defects and improving free charge separation. As a result, inorganic CsPbI 3 PSCs with HiBT HTM achieved an impressive power conversion efficiency (PCE) of 20.58%, the highest reported for dopant‐free HTM‐based inorganic PSCs. Moreover, the enhanced hydrophobic properties of HiBT molecules, coupled with their ability to passivate perovskite surface defects, contribute to significantly improved device stability. The unencapsulated devices based on HiBT HTM retained over 83% and 80% of their initial efficiency after being stored at 85 °C for 50 days and undergoing maximum power point (MPP) tracking at 85 °C for 1100 h, respectively. These results highlight that the symmetry‐breaking strategy is an exceptionally effective approach for designing efficient, dopant‐free small molecule HTMs, significantly contributing to both the high efficiency and enhanced stability of all‐inorganic PSCs.

Chemistry

Adaptive Curation at NASA Johnson Space Center: Preparing for Artemis Samples by Leveraging Proven Practices and Innovative Solution

The proper curation of returned astromaterial samples is essential to ensure that high-quality scientific investigations can be conducted for decades, enabling future generations to address evolving research questions. The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is responsible for curating all of NASA’s extraterrestrial samples. Under the governing document, NASA Procedural Requirement (NPR) 7100.5 “Curation of Extraterrestrial Materials”, JSC Curation is charged with “The curation of all extraterrestrial material under NASA control, including future NASA missions.” The Directive goes on to define Curation as including “...documentation, preservation, preparation, and distribution of samples for research, education, and public outreach.” JSC Curation has a long-standing legacy of curating extraterrestrial materials, including but not limited to Apollo and Luna lunar samples, Genesis solar wind samples, Stardust comet samples, asteroid samples (Hayabusa1, Hayabusa2, and OSIRIS-REx), and Antarctic Meteorite samples from a variety of parent bodies. Building on this foundation, the Artemis program introduces new challenges and opportunities for sample curation, requiring both the application of proven practices and the development of innovative solutions. The Artemis Collection will be curated using established protocols refined through decades of experience with Apollo and subsequent sample collections, including but not limited to the utilization of cleanrooms, custom nitrogen gloveboxes, specialized storage containers and tools; all of which have strict material utilization and prohibition requirements. These practices provide a robust framework for contamination control, documentation, and long-term preservation. However, Artemis samples may present unique scientific and operational requirements, including enhanced contamination control measures (relative to Apollo) driven by evolving science objectives. To meet these needs, JSC Curation is actively developing new technologies and protocols that extend beyond traditional approaches, ensuring that the integrity of samples is maintained under increasingly stringent standards. One critical area of innovation is the development of cold sample curation capabilities. Certain Artemis samples, particularly those from Permanently Shadowed Regions (PSRs) and cold environments, are expected to contain ices and volatile components that require preservation and handling at sub-zero or even cryogenic temperatures. JSC Curation is leveraging best practices from the cold and cryogenic sample industries, as well as other government agencies and academic experts, to design facilities and handling procedures that maintain sample integrity while enabling scientific access. The goal is to develop capabilities to allow researchers to investigate volatiles and other temperature-sensitive materials while minimizing chemical and physical alterations from their returned state. In summary, adaptive curation at JSC combines the reliability of proven methodologies with forward-looking innovations to meet the scientific and operational demands of Artemis. Through enhanced contamination control, advanced cold curation capabilities, and an understanding of known and evolving future science priorities, NASA is preparing to maximize the scientific return from Artemis samples and preserve their value for generations of researchers.

Andrea D Harrington

Thermally Stable Co@C3N4 Single-Atom Catalysts for CO Oxidation: Atomic-Level Insights into Structure and Activity

Single Co atoms supported on C3N4 (Co@C3N4) have demonstrated high activity and selectivity in photocatalysis. However, the investigation of structure–function relationships and reaction mechanisms under photocatalytic conditions is very challenging due to the complex conditions of light absorption, charge transfer, and catalysis. In this study, we employed thermal CO oxidation as a prototypical probe reaction to benchmark the intrinsic catalytic performance and track the active-site evolution of Co@C3N4. Single Co atoms were identified and shown to be the catalytically active sites for CO oxidation based on control experiments and isotope-labeling experiments. The Co sites remained atomically dispersed before, during, and after the reaction with temperatures up to 400 °C, as established by in situ X-ray absorption fine structure (XAFS) combined with density functional theory (DFT), FDMNES simulations, and dynamic-time-warping (DTW)-assisted X-ray absorption near edge structure (XANES) matching. Together with theoretical calculations, the integrated analysis reveals a stable coordination environment under reaction conditions, which correlates with sustained activity, establishing Co@C3N4 single-atom catalysts as thermally stable CO oxidation catalysts. Beyond these findings, the current study provides a workflow for unambiguously assigning active sites in Co@C3N4 for thermal CO oxidation. This workflow will aid the understanding of their behavior in photocatalysis in the future, where light-driven dynamics obscure direct structure–function links. Notably, this study provides fundamental insights for the rational design of robust single-atom catalysts and a foundation for the broader application of Co@C3N4 catalysts in oxidation reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Tracing the Source of Carbon Oxides on the Large Moons of Uranus

The Uranian moons Ariel, Umbriel, Titania, and Oberon are enriched in CO 2 mixed with CO, but the origin(s) of these carbon oxides, be they primarily native or radiolytic, remain(s) uncertain. Using data collected by NIRSpec on the James Webb Space Telescope (JWST), we measured the spectral signature of CO 2 and other carbon oxides to help disentangle these hypotheses. Through comparison to laboratory data, we find that many of the detected spectral features are consistent with CO 2 ice, including 12 CO2 scattering peaks (4.15–4.26 μm), multilobe 13 CO 2 bands (4.35–4.43 μm), and CO 2 biphonon and triphonon modes (4.80–5.25 μm). Our measurements show that CO 2 and CO are concentrated on the trailing hemispheres of the inner moons Ariel and Umbriel, potentially supporting a radiolytic production hypothesis, consistent with prior ground-based results. However, many of the identified spectral features are only observed in thick crystalline ice deposits measured in the laboratory, which may be difficult to form via radiolysis of carbon-bearing material mixed in icy regoliths. Similarly, the data exhibit weak 4.02 and 4.40 μm bands, hinting at the presence of carbonate minerals and 13 CO 2 clathrates, respectively, possibly formed in the interiors of these moons. Furthermore, JWST has revealed that CO 2 is widespread at Uranus, present in its system of rings, ring moons, and irregular satellites, consistent with its largest moons accreting CO 2 and other carbon oxides from the Uranian subnebula. We conclude that exposed carbon oxides are potentially native, with their surface distributions shaped by charged particle irradiation and seasonal sublimation–condensation cycles.

Ice spectroscopy

Bipolar Ag-Zn battery

The silver-zinc (AgZn) battery system has been unique in its ability to safely satisfy high power demand applications with low mass and volume. However, a new generation of defense, aerospace, and commercial applications will impose even higher power demands. These new power demands can be satisfied by the development of a bipolar battery design. In this configuration the power consuming, interelectrode current conductors are eliminated while the current is then conducted via the large cross-section electrode substrate. Negative and positive active materials are applied to opposite sides of a solid silver foil substrate. In addition to reducing the weight and volume required for a specified power level, the output voltage performance is also improved as follows. Reduced weight through: elimination of the plastic cell container; elimination of plate leads and intercell connector; and elimination of internal plate current collector. Increased voltage through: elimination of resistance of current collector; elimination of resistance of plate lead; and elimination of resistance of intercell connector. EPI worked previously on development of a secondary bipolar silver zinc battery. This development demonstrated the electrical capability of the system and manufacturing techniques. One difficulty with this development was mechanical problems with the seals. However, recent improvements in plastics and adhesives should eliminate the major problem of maintaining a seal around the periphery of the bipolar module. The seal problem is not as significant for a primary battery application or for a requirement for only a few discharge cycles. A second difficulty encountered was with activation (introducing electrolyte into the cell) and with venting gas from the cell without loss of electrolyte. During previous work, the following projections for energy density were made from test data for a high power system which demonstrated in excess of 50 discharge/charge cycles. Projected system power = 100 kilowatts; discharge time = 30 seconds; discharge current density = 1.75 amps/sq in.; system weight = 86 lbs (9.7 WH/lb); and system volume = 1071 cu. in. (.78 WH/cu. in.). EPI is currently working on a development program to produce a bipolar silver-zinc battery design for NASA. The potential application would be to power electromechanical actuators for space launch vehicles.

Giltner, L. John

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics

SUDA: A SUrface Dust Analyser for Compositional Mapping of the Galilean Moon Europa

Abstract The Surface Dust Analyser (SUDA) is a mass spectrometer onboard the Europa Clipper mission for investigating the surface composition of the Galilean moon Europa. Atmosphereless planetary moons such as the Galilean satellites are wrapped into a ballistic dust exosphere populated by tiny samples from the moon’s surface produced by impacts of fast micrometeoroids. SUDA will measure the composition of such surface ejecta during close flybys of Europa to obtain key chemical signatures for revealing the satellite’s composition such as organic molecules and salts, history, and geological evolution. Because of their ballistic orbits, detected ejecta can be traced back to the surface with a spatial resolution roughly equal to the instantaneous altitude of the spacecraft. SUDA is a Time-Of-Flight (TOF), reflectron-type impact mass spectrometer, optimized for a high mass resolution which only weakly depends on the impact location. The instrument will measure the mass, speed, charge, elemental, molecular, and isotopic composition of impacting grains. The instrument’s small size of$268 ~\mathrm {mm} \times 250 ~\mathrm {mm} \times 171$ 268 mm × 250 mm × 171 $~\mathrm {mm}$ mm , radiation-hard design, and rather large sensitive area of 220 cm 2 matches well the challenging demands of the Clipper mission.

Astronomy & Astrophysics

Introduction to Radiation Issues for International Space Station Extravehicular Activities: Chapter 1

The International Space Station (ISS) provides significant challenges for radiation protection of the crew due to a combination of circumstances including: the extended duration of missions for many crewmembers, the exceptionally dynamic nature of the radiation environment in ISS orbit, and the necessity for numerous planned extravehicular activities (EVA) for station construction and maintenance. Radiation protection requires accurate radiation dose measurements and precise risk modeling of the transmission of high fluxes of energetic electrons and protons through the relatively thin shielding provided by the space suits worn during EVA. Experiments and analyses have been performed due to the necessity to assure complete radiation safety for the EVA crew and thereby ensure mission success. The detailed characterization described of the material and topological properties of the ISS space suits can be used as a basis for design of space suits used in future exploration missions. In radiation protection practices, risk from exposure to ionizing radiation is determined analytically by the level of exposure, the detrimental quality of the radiation field, the inherent radiosensitivity of the tissues or organs irradiated, and the age and gender of the person at the time of exposure. During low Earth orbit (LEO) EVA, the relatively high fluxes of low-energy electrons and protons lead to large variations in exposure of the skin, lens of the eye, and tissues in other shallow anatomical locations. The technical papers in this publication describe a number of ground-based experiments that precisely measure the thickness of the NASA extravehicular mobility unit (EMU) and Russian Zvezda Orlan-M suits using medical computerized tomography (CT) X-ray analysis, and particle accelerator experiments that measure the minimum kinetic energy required by electrons and photons to penetrate major components of the suits. These studies provide information necessary for improving the understanding of the current ISS space suits and provide insights into improved approaches for the design of future suits. This chapter begins with a summary of the dynamic ionizing radiation environment in LEO space and introduces the concepts and quantities used to quantify exposure to space radiation in LEO. The space suits used for EVA and the experimental partial human phantom are described. Subsequent chapters report results from measured charged particle fields before and after incident protons and secondary particles are transported through the space suits and into organs and tissues.

M R Shavers

Search for soft unclustered energy patterns produced in association with a W or Z boson in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search for a Higgs boson produced in association with a W or Z boson and decaying via a soft unclustered energy pattern (SUEP) is presented. The analysis is based on proton-proton collision data corresponding to an integrated luminosity of 138 fb −1 collected between 2016 and 2018 at the LHC. Final states with a leptonic W or Z boson decay associated with a high multiplicity of low-momentum charged particles are explored for the first time. The results show no significant excess over the standard model background expectation. Limits are set on the production cross section of a Higgs boson that decays to a SUEP, for a range of parameters of the SUEP model. Material is provided to facilitate further interpretation of the results.

CMS

Exposure of Highly Reflective Far-Ultraviolet Coatings to LEO Environment for TRL Advancement for the Habitable Worlds Observatory

Over the past several years, our team at the NASA Goddard Space Flight Center (GSFC), in collaboration with the Jet Propulsion Laboratory (JPL) and the Naval Research Laboratory (NRL), have developed several new protected Al coating technologies with improved Far-Ultraviolet (FUV) reflectance performance and more robust environmental stability. These include Al protected with lithium-based fluoride (LiF) coatings such as hot deposited LiF (eLiF), XeF 2 -passivated LiF coatings (XeLiF), Li 3 AlF 6 overcoats, AlF 3 (plasma passivated), and XeF 2 passivated MgF 2 coatings (XeMgF 2 ). However, despite these developments, relatively little experimental information exists regarding the long-term stability of these coatings after simultaneous exposure to the Low Earth Orbit (LEO) environment. To evaluate their environmental durability and advance their Technology Readiness Level (TRL), representative samples of these coating technologies, Al+XeLiF, Al+eLiF, Al+Li 3 AlF 6 , Al+AlF 3 , Al+XeMgF 2 , and bare Al as reference samples, were flown onboard the International Space Station (ISS) as part of the Materials International Space Station Experiment 20 (MISSE-20). The MISSE platform is operated by Aegis Aerospace for relatively long-duration (e.g. 6 months) external exposure experiments in a space environment. The coatings were deposited on ULE and Zerodur substrates, and witness samples deposited on the same coatings runs, but on glass slides were left on Earth as control. A subset of the flight samples were fitted with MgF 2 windows to reduce direct exposure to atomic oxygen (AO) and charged particles, and still let through UV and other types of radiation on these samples. After approximately 6 months of exposure in the forward-facing (RAM) direction, the samples were returned to Earth and characterized by performing FUV/NUV/VIS/NIR reflectance measurements to quantify degradation, spectroscopic ellipsometry to evaluate coating thickness and optical constants, atomic force microscopy (AFM) to quantify surface roughness evolution during the flight in the ISS. The MgF 2 protective windows were also analyzed through FUV transmission measurements. Comparison with the witness samples left on the ground and with the flown bare Al samples (with just the naturally occurring Al 2 O 3 layer) provided a quantitative assessment of coating thickness variations, optical performance degradation, and morphological changes induced by prolonged exposure to the LEO environment.

Far Ultraviolet (FUV)

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

First measurement of polarized spin-density matrix elements and differential cross sections dσ/dt in ω photoproduction off the proton for 2.7 < Eγ < 5.2 GeV using CLAS at Jefferson Lab

We report on the differential cross sections dσ/dt, the unpolarized spin-density matrix elements ρ 00 0 , ρ 1 − 1 0 , Re ρ 10 0 , and the first extraction of the polarized elements Im ρ 10 3 , Im ρ 1 − 1 3 for the reaction γp → pω using the CLAS spectrometer at Jefferson Laboratory. The ω mesons were detected in their dominant charged decay mode, ω → π + π − π 0 , and all t-dependent results are presented in a fine binning for incident photon energies between 2.73 and 5.16 GeV (corresponding to the center-of-mass energy range W ∈ [ 2.45, 3.25 ] GeV). All matrix elements are first measurements for − t > 0.6 GeV2. Moreover, differential cross sections dσ/d(cos Θ c . m . ω ) and the corresponding angle-dependent unpolarized spin-density matrix elements in the Adair frame are presented for the incident photon energy range 1.56–3.80 GeV (corresponding to W ∈ [ 1.95, 2.83 ] GeV). These new ω photoproduction data are consistent with earlier CLAS results but extend the energy range well beyond the nucleon resonance region into the Regge regime. The comparison with Regge-theory-based model predictions shows that the new data impose more stringent constraints on our understanding of ω photoproduction.

Hu, T.

The DUNE Far Detector Vertical Drift Technology. Technical Design Report

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.

47 OTHER INSTRUMENTATION

Single-Nucleon Transfer on Unstable 59 Cu Probes the NiCu Cycle in Astrophysical X-Ray Bursts

Recent models of the rapid proton (𝑟⁢𝑝) capture process indicate that a competition between the 59 Cu⁢(𝑝,𝛾) ⁢60 Zn and 59 Cu⁢(𝑝,𝛼) ⁢56 Ni reactions may result in the formation of a nickel-copper (NiCu) cycle that traps the flux of material between 56 Ni and 60 Zn . Here, in this work, we report the identification of 15 proton-unbound levels in 60 Zn , populated via 59 Cu⁢(𝑑,𝑛) transfer, which govern the rate of the 59 Cu⁢(𝑝,𝛾)⁢ 60 Zn reaction in XRBs. Precise excitation energies for levels in 60 Zn were obtained from observed 𝛾 decays, and spectroscopic factors were determined from angle-integrated cross sections. Incorporating these results into stellar-model calculations, we find that with experimentally constrained uncertainties a NiCu cycle in XRBs is indeed possible, though we limit its branching strength to less than 38%. While modest, such a branching has significant impact on the light curve, motivating further studies of the relevant rates. Our calculations also indicate that a significant NiCu cycle leads to an increase in the amount of odd-𝐴 nuclei in the burst ashes, which may affect Urca cooling processes in neutron star crusts.

direct reactions

The MuFusE large-volume diamond anvil cell for exploring muon-catalyzed fusion at higher pressures and temperatures

A new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion (μCF) Experiment (MuFusE), enabling the compression and heating of deuterium–tritium (d–t) mixtures to pressures and temperatures needed to advance μCF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm 3 at liquid density, pressures up to 933 MPa and temperatures up to 400 K—benchmarks that significantly exceed previously reported limits for static d–t targets.

Kalow, J. D. [Acceleron Fusion, Inc., Cambridge, M

Paleotribological models using preserved fossil tissue properties reveal functional significance of Eurasian mammoth dental evolution

Eurasian mammoths (Mammuthus) underwent substantial modifications in molar morphology as later-diverging species evolved progressively thinner enamel and increased enamel crest complexity. These features have been hypothesized to reduce whole-tooth wear and extend dental longevity as increasingly graze-dominated diets evolved within the lineage. This hypothesis has yet to be directly tested. Here, in this study, we developed an in-silico wear model using experimentally derived wear rates from fossil and extant proboscidean dental tissues. The models revealed that shifts in tissue topology do not affect whole-tooth wear rate, as inverse trends in lamellar frequency and enamel thickness preserve a consistent surface enamel area fraction; the determining factor of wear. Rather, topological shifts produce a wear-emergent secondary occlusal surface with greater numbers of triturating crests that create a regular, low-relief, file-like shearing pavement. These changes in occlusal architecture likely directly impacted the mastication capacity of Mammuthus dentitions, facilitating their dietary expansion to incorporate fibrous, lower-nutrient graze.

Dental wear