Search NASASearch

SEARCH · Search NASA

Results for “effective field theories”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,139 records · Page 25

Mitigation of polysulfide shuttle effect in Li-S batteries through catalytic disproportionation reaction

Polysulfides are poorly retained within porous cathodes and readily diffuse into the electrolyte over time, leading to the well-known shuttle effect that undermines the reversibility of Li-S batteries. Here, in this study, we demonstrate that catalytic disproportionation of polysulfides provides an effective pathway to suppress this process by rapidly converting dissolved species into solid sulfur and sulfides, thereby preventing their migration into the electrolyte. Fundamentally, the sluggish kinetics of sulfur redox reactions are responsible for the accumulation and redistribution of soluble polysulfides in the bulk electrolyte. By accelerating these kinetics, catalyzed disproportionation not only confines sulfur within the conductive cathode matrix but also promotes the homogeneous precipitation of Li₂S₂/Li₂S, which enhances electrochemical reversibility and cycling stability. Using nitrogen-doped carbon (NC800) as a model catalyst, we reveal its ability to drive a pseudo-16-electron reduction pathway, leading to a single dominant Li₂S product and uniform deposition within the porous framework. In contrast, a non-catalytic carbon (KB) yields multiple polysulfide intermediates and heterogeneous deposition. The mechanistic insights provided here highlight the pivotal role of catalytic disproportionation in reshaping sulfur redox pathways and offer a rational strategy for mitigating polysulfide shuttling in practical Li-S pouch cells.

25 ENERGY STORAGE

Prospects of Nanoscience with Nanocrystals: 2025 Edition

Abstract Nanocrystals (NCs) of various compositions have made important contributions to science and technology, with their impact recognized by the 2023 Nobel Prize in Chemistry for the discovery and synthesis of semiconductor quantum dots (QDs). Over four decades of research into NCs has led to numerous advancements in diverse fields, such as optoelectronics, catalysis, energy, medicine, and recently, quantum information and computing. The last 10 years since the predecessor perspective “Prospect of Nanoscience with Nanocrystals” was published in ACS Nano have seen NC research continuously evolve, yielding critical advances in fundamental understanding and practical applications. Mechanistic insights into NC formation have translated into precision control over NC size, shape, and composition. Emerging synthesis techniques have broadened the landscape of compounds obtainable in colloidal NC form. Sophistication in surface chemistry, jointly bolstered by theoretical models and experimental findings, has facilitated refined control over NC properties and represents a trusted gateway to enhanced NC stability and processability. The assembly of NCs into superlattices, along with two-dimensional (2D) photolithography and three-dimensional (3D) printing, has expanded their utility in creating materials with tailored properties. Applications of NCs are also flourishing, consolidating progress in fields targeted early on, such as optoelectronics and catalysis, and extending into areas ranging from quantum technology to phase-change memories. In this perspective, we review the extensive progress in research on NCs over the past decade and highlight key areas where future research may bring further breakthroughs.

Chemistry

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Nickel-cadmium Battery Cell Reversal from Resistive Network Effects

During the individual cell short-down procedures often used for storing or reconditioning nickel-cadmium (Ni-Cd) batteries, it is possible for significant reversal of the lowest capacity cells to occur. The reversal is caused by the finite resistance of the common current-carrying leads in the resistive network that is generally used during short-down. A model is developed to evaluate the extent of such a reversal in any specific battery, and the model is verified by means of data from the short-down of a f-cell, 3.5-Ah battery. Computer simulations of short-down on a variety of battery configurations indicate the desirability of controlling capacity imbalances arising from cell configuration and battery management, limiting variability in the short-down resistors, minimizing lead resistances, and optimizing lead configurations.

Zimmerman, A. H.

Surface analysis insight note: Illustrating the effect of adventitious contamination on Pt photoemission peak intensities

Adventitious carbon contaminations are not only omnipresent and used for charge referencing of XPS spectra but also can alter the apparent presence of the element peaks that span over the large spectral window of binding energies. This Insight note describes the effect of an adventitious contamination layer on Pt and presents, in brief, the approach whereby the component spectra are derived for ion beam cleaned Pt samples that can then utilize linear mathematics to peak fit said spectra thus quantifying the amount of each component including that assigned to the contamination itself of Pt metal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

IUS materials outgassing condensation effects on sensitive spacecraft surfaces

Four materials used on the inertial upper state (IUS) were subjected to vacuum conditions and heated to near-operational temperatures (93 to 316 C), releasing volatile materials. A fraction of the volatile materials were collected on 25 C solar cells, optical solar reflectors (OSR's) or aluminized Mylar. The contaminated surfaces were exposed to 26 equivalent sun hours of simulated solar ultraviolet (UV) radiation. Measurements of contamination deposit mass, structure, reflectance and effects on solar cell power output were made before and after UV irradiation. Standard total mass loss - volatile condensible materials (TML - VCM) tests were also performed. A 2500 A thick contaminant layer produced by EPDM rubber motor-case insulation outgassing increased the solar absorptance of the OSR's from 0.07 to 0.14, and to 0.18 after UV exposure. An 83,000 A layer caused an increase from 0.07 to 0.21, and then the 0.46 after UV exposure. The Kevlar-epoxy motor-case material outgassing condensation raised the absorptance from 0.07 to 0.13, but UV had no effect. Outgassing from multilayer insulation and carbon-carbon nozzle materials did not affect the solar absorptance of the OSR's.

C. R. Mullen

On the isotopic signature of recent solar-wind nitrogen

One of the most intriguing discoveries yielded by the Apollo samples was evidence pointing towards a significant long-term change in the composition of the sun. Such a change, of the size inferred from the lunar sample data, is inconsistent with present theories of solar evolution. Consequently, there is much interest in exploring this phenomenon as closely as possible, to determine exactly what compositional changes have taken place and whether those changes really did take place in the sun, or whether the cause lies elsewhere. The reason why we can use the moon to analyze the elements in the sun is that the sun emits a stream of ions, known as the solar wind, whose composition, on average, is believed to be the same as that in the surface regions of the sun. When the solar-wind ions hit the surface of the moon, many of them penetrate a short distance into the dust grains lying on the lunar surface. Thus, after a grain has sat on the lunar surface for a while, it has a rim of material that is partly lunar and partly solar in composition. For most chemical elements, the difference between lunar and solar composition is so sufficiently small that the solar elements cannot be detected, but for a handful of elements that are missing from the moon, their solar 'signature' can be observed in samples of lunar soil brought back by the astronauts. Among those elements is nitrogen, the most common element in the air we breathe, but very rare indeed on the moon. Our analytical techniques are not sophisticated enough yet to enable us to analyze individual lunar soil grains for nitrogen, much less to zero in on just the nitrogen in the surface of such a grain. Consequently we are forced to analyze samples consisting of many different grains, each of which could have experienced its own individual history. This makes it difficult to identify the nitrogen implanted in grain surfaces, and also to define the age of a sample.

Kim, Y.

Design Strategies Based on Electronic Interactions for Effective Catalysts in Lithium–Sulfur Batteries

Abstract Lithium–sulfur batteries (LSBs) are considered promising next‐generation batteries due to their high energy density (>500 W h kg −1 ). However, LSBs exhibit an unsatisfactory energy density (<400 W h kg −1 ) and cycle life (<300 cycles) because of the shuttle effect caused by soluble lithium polysulfide (LiPS) intermediates and the sluggish conversion reaction kinetics caused by insulating sulfur (S 8 ) and lithium sulfide (Li 2 S). Although various types of catalysts, including metal‐based compounds to single‐atom catalysts, have been reported to address these issues, most catalysts exhibited limited catalytic activity under practical lean electrolyte conditions (<5 µL mg −1 ). A comprehensive understanding of the synthetic strategy and catalytic mechanism of catalysts is essential for their design, but understanding the electronic effects of the catalysts and LiPS is more important. Furthermore, the electronic design of these catalysts is not well understood. In this review, we introduce the catalytic mechanisms in LSBs and discuss catalyst design strategies in terms of electronic effects on the interactions between reactants and catalysts, with a primary focus on heterogeneous catalytic systems. We additionally consider how the electronic property of homogeneous systems, particularly redox mediators, affects catalytic behavior under lean electrolyte conditions and propose future research directions for catalyst development in LSBs.

Chemistry

Technology & Design Innovations to Maximize the Reduction Effect on DCFC Unit Cost Economics (Max‐REDUCE)

With the high cost and reliability issues of DCFC infrastructure the project specifically addressed the needs of innovating on the AC to DC power conversion. We proved the integration of a new power module into existing charger units, and that theoretical educational work on single stage energy conversion is commercially viable, and a reduced cost compared to existing methods. Our A sample shown 3 PH 480VAC 60hz to 350VDC 8.5kW power transfer, and our software and simulation proved efficiency greater than 97% from 20kW to > 60kW, over the DC output voltage range 200 – 1200V. The project was stopped before we could implement B sample and execute full power testing, validation and integration into a demonstration charger (budget period 3).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Lunar Surface Crater Thermal Effects on Lander Radiator Performance

Lunar surface craters smaller than the spatial resolution of surface meshes used in typical Lunar surface thermal models (10 to 60 meters per pixel) may impact the accuracy of thermal model extrema predictions. The goal of this study is to investigate the thermal sensitivity of representative lander systems with realistic thermal surface orientations in bare and cratered terrain environments at relevant Artemis mission locations. This thermal analysis task investigates the impact of lunar surface craters on lander radiator performance by comparing heat rejection capability results between bare and cratered terrain environments. This study examines external body-mounted lander radiator thermal performance across varying lander heights (5.5m, 20m, 50m) and radiator orientations (horizontal, 45º tilted, and vertical) at two representative Artemis mission latitudes (-89.5ºS and -82.5ºS), spanning from the Shackleton Connecting Ridge to Mons Mouton Plateau.

Lunar Surface

Bipolar Nickel-Metal Hydride Battery Being Developed

The NASA Lewis Research Center has contracted with Electro Energy, Inc., to develop a bipolar nickel-metal hydride battery design for energy storage on low-Earth-orbit satellites. The objective of the bipolar nickel-metal hydride battery development program is to approach advanced battery development from a systems level while incorporating technology advances from the lightweight nickel electrode field, hydride development, and design developments from nickel-hydrogen systems. This will result in a low-volume, simplified, less-expensive battery system that is ideal for small spacecraft applications. The goals of the program are to develop a 1-kilowatt, 28-volt (V), bipolar nickel-metal hydride battery with a specific energy of 100 watt-hours per kilogram (W-hr/kg), an energy density of 250 W-hr/liter and a 5-year life in low Earth orbit at 40-percent depth-of-discharge.

Manzo, Michelle A.

Durability of ABC Team Wall Assemblies

This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Graphitization of banana peel – synergistic effect of Ca and other elements of the biomass on carbon structure transformation

Recently, growing interest has been observed in using calcium as an effective catalyst for graphitizing disordered carbon materials derived from biomass and bioprecursors, such as cellulose and lignin, at relatively low tem peratures (<2000 °C). Herein, it is demonstrated that in the presence of elements such as calcium, silicon, sulfur, and potassium, which are abundant in banana peel composed of cellulose and lignin base, graphitization occurs much more effectively. The addition of external calcium source, in the form of calcium carbonate, to the banana peel-derived carbon and heat-treatment of the mixture under protective atmosphere up to 1750 °C results in a significant increase in the degree of the graphitization order and local formation of graphite crystals, whereas the same preparation and heat-treatment procedure applied to carbon material derived from pristine cellulose does not lead to such effective graphitization. It is indicated that the graphitization of banana peel carbon occurs due to the synergistic effect of the external Ca-based catalyst and the internal elements present in the raw biomass, supporting the transformation of the disordered graphene-like layers into graphitic structures. These findings are important for the future production of green graphite from biomass

09 BIOMASS FUELS

Validation Data for Benchmarking Wire Arc Additive Manufacturing Process Simulations

Residual stresses cause geometric distortion and affect mechanical performance of additively manufactured structures, yet they are notoriously difficult to assess and predict. Distortion (warpage) can drive parts outside dimensional tolerance limits, leading to part rejection or rework. For parts that meet tolerance, locked-in residual stress fields can affect structural integrity during operation, particularly subcritical cracking by fatigue, creep, or corrosion. This work develops benchmark data for a common additive manufacturing process (Wire Arc Additive Manufacturing) that can be applied for calibration and validation of physical process models that predict residual stress fields. The work includes design of two different samples of differing geometry, detailed manufacturing records for a set of physical samples, and an extensive set of residual stress measurement data developed using two diverse techniques (the contour method and neutron diffraction). An initial application of the work is also reported, where a modeling challenge was issued to secure residual stress model predictions from two independent laboratories that were blind to residual stress measurement data. These initial blind residual stress predictions show significant discrepancies relative to the measurement data, illustrating the potential value of the underlying validation data. An open repository for this work, including the sample designs, manufacturing process records, and the residual stress data, is also provided for future application in non-blind validation efforts.

36 MATERIALS SCIENCE

Assessing the Impact of a Forest Canopy on Near-Surface Wind Statistics

Representing the forest canopy in atmospheric numerical models should improve simulated winds within and above the canopy up to a few hundred meters above the ground. Here, in this study, we implement a forest canopy parameterization into the Weather Research and Forecasting (WRF) Model in a large-eddy simulation (LES) mode by applying drag forces across multiple layers within the canopy height. We use unique observations from the Lidar Experiments for Assessing Flow over Forests (LEAFF) field campaign at the Wind River Experimental Forest (WREF) in the U.S. Pacific Northwest to evaluate model performance. In a 2-day case study, the canopy parameterization improved wind predictions both within and above the canopy, particularly during the daytime and at finer grid resolution. Without it, winds were frequently overpredicted above the canopy. Similarly, derived quantities such as the wind shear index also yielded estimates closer to observations with the canopy parameterization implemented. These findings suggest that representing the canopy using drag forces alone can improve simulated mean winds up to 200 m above the surface. Furthermore, second-order statistical moments of wind were more sensitive to canopy density than first-order moments, especially during the daytime. This increased sensitivity and the improved daytime performance in wind speed—evidenced by the lowest bias from observations (3% compared to 20% over diurnal cycle)—imply that winds above the canopy layer are strongly influenced by how well turbulence above the canopy is modeled. The results of this study can serve as a foundation for parameterizing forest canopy effects in coarser weather forecast models.

Energy - Wind

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)