Search NASASearch

SEARCH · Search NASA

Results for “cosmology of theories beyond the SM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,724 records · Page 27

The occurrence rate of galaxies with polar structures may be significantly underestimated

Polar-ring galaxies are photometrically and kinematically decoupled systems that are highly inclined to the major axis of the host. These galaxies have been explored since the 1970s, but the rarity of these systems has made such systematic studies difficult. However, over 250 good candidates have been identified. In this work, we examine a sample of over 18 000 galaxies from the Sloan Digital Sky Survey (SDSS) Stripe 82 for the presence of galaxies with polar structures. Using deep SDSS Stripe 82, DESI Legacy Imaging Surveys, and Hyper Suprime-Cam Subaru Strategic Program, we selected 53 good candidate galaxies with photometrically decoupled polar rings, 9 galaxies with polar halos, 6 galaxies with polar bulges, and 34 possibly forming polar-ring galaxies, versus 13 polar-ring candidates previously selected in Stripe 82. Our results suggest that the occurrence rate of galaxies with polar structures may be significantly underestimated, as revealed by the deep observations, and may amount to 1–3% of non-dwarf galaxies.

Astronomy & Astrophysics

Oxidation Chemistry of Bicarbonate and Peroxybicarbonate: Implications for Carbonate Management in Energy Storage

Carbonate formation presents a major challenge to energy storage applications based on low-temperature CO 2 electrolysis and recyclable metal–air batteries. While direct electrochemical oxidation of (bi)carbonate represents a straightforward route for carbonate management, knowledge of the feasibility and mechanisms of direct oxidation is presently lacking. Herein, we report the isolation and characterization of the bis(triphenylphosphine)iminium salts of bicarbonate and peroxybicarbonate, thus enabling the examination of their oxidation chemistry. Infrared spectroelectrochemistry combined with time-resolved infrared spectroscopy reveals that the photoinduced oxidation of HCO 3 – by an Ir(III) photoreagent results in the generation of the short-lived bicarbonate radical in less than 50 ns. The highly acidic bicarbonate radical undergoes proton transfer with HCO 3 – to furnish the carbonate radical anion and H 2 CO 3 , leading to the eventual release of CO 2 and H 2 O, thus accounting for the appearance of H 2 O and CO 2 in both electrochemical and photochemical oxidation experiments. Here, the back reaction of the carbonate radical subsequently oxidizes the Ir(II) photoreagent, leading to carbonate. In the absence of this back reaction, dimerization of the carbonate radical provides entry into peroxybicarbonate, which we show undergoes facile oxidation to O 2 and CO 2 . Together, the results reported identify tangible pathways for the design of catalysts for the management of carbonate in energy storage applications.

25 ENERGY STORAGE

Observational evidence for Criegee intermediate oligomerization reactions relevant to aerosol formation in the troposphere

Criegee intermediates are reactive intermediates that are implicated in transforming the composition of Earth’s troposphere and in the formation of secondary organic aerosol, impacting Earth’s radiation balance, air quality and human health. Yet, direct identification of their signatures in the field remains elusive. Here, from particulate and gas-phase mass-spectrometric measurements in the Amazon rainforest, we identify sequences of masses consistent with the expected signatures of oligomerization of the CH 2 OO Criegee intermediate, a process implicated in ozonolysis-driven aerosol formation. In this study, we assess the potential contributions of oligomerization through laboratory ozonolysis experiments, direct kinetic studies of Criegee intermediate reactions, and high-level theoretical calculations. Global atmospheric models built on these kinetics results indicate that Criegee intermediate chemistry may play a larger role in altering the composition of Earth’s troposphere than is captured in current atmospheric models, especially in areas of high humidity. However, the models still capture only a relatively small fraction of the observed signatures, suggesting considerable underestimates of Criegee intermediate concentrations and reactivity and/or the dominance of other, presently uncharacterized, oxidation mechanisms. Resolving the remaining uncertainties in emission inventories and the effects of atmospheric water vapour on key chemical reactions will be required to definitively assess the role of Criegee intermediate oligomerization reactions.

58 GEOSCIENCES

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio

Nanoscale Observation and Control of Quasiparticle Induced Magnetic Noise in a Superconducting Resonator

Superconducting circuits are arguably taking a leading role in driving the ongoing quantum technological revolution. A detailed knowledge of the microscopic fluctuating electromagnetic properties plays an important role in advancing the circuitry design, testing, and material integration of cutting-edge superconducting quantum electronics. Here, in this work, we report scanning nitrogen-vacancy (NV) quantum sensing of local magnetic noise environment of an on-chip superconducting resonator. We find that quasiparticle-induced fluctuating magnetic fields can drive NV spin relaxation, which shows a peak value around the superconducting transition point of niobium at the thermal equilibrium state. External microwave driving at the resonator mode frequency significantly increases the quasiparticle density, leading to enhancement of magnetic noise. We further perform optically detected magnetic resonance measurements to demonstrate quasiparticle magnetic noise mediated off-resonant dipole coupling between the NV center and niobium resonator. Our Letter reports experimental observation of the Hebel-Slichter peak signature by an external sensor outside of a superconductor. The presented study also highlights the advantages of quantum sensors in investigating miniaturized superconducting devices, providing insights into their future performance improvements.

Li, Senlei [Georgia Institute of Technology]

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed

Seasonal variation of the surface cross-shelf exchange in the northern South China Sea: a Lagrangian perspective

Previous studies on cross-shelf exchange, predominantly adopted an Eulerian perspective, struggled to identify water sources and pathways. Using a high-resolution regional ocean modeling system (ROMS) and Lagrangian particle tracking, this study systematically investigates the seasonal variation and dynamics of surface cross-shelf exchange in the northern South China Sea (NSCS) from a Lagrangian perspective. Based on daily released 30-day drifter trajectories we identify the key pathways, source regions for surface cross-shelf exchange, revealing pronounced seasonal variability. Results show the surface cross-shelf exchange generally following monsoon-driven Ekman transport. However, local dynamics, especially topographic modulation, can outweigh the expected Ekman-driven transport, producing surface exchange patterns opposite to that predicted from the prevailing winds. Topographic effects vary across different scales. In the coastal waters of western Guangdong during winter, despite downwelling-favorable winds, the modulation of alongshore currents by island topography induces an eastward pressure gradient. This gradient, through geostrophic balance, drives offshore flows opposite to wind-driven Ekman onshore transport. Furthermore, the eastern widened shelf exhibits a distinct seasonal variation of cross-shelf exchange, with strong offshore transport (opposite to the direction of Ekman transport) in winter and exceedingly weak exchange in summer. Analysis of the underlying mechanisms reveals that this winter offshore transport is primarily attributed to geostrophic flows driven by surface pressure gradient that is jointly modulated by the Kuroshio intrusion and local widened shelf topography, and enhanced by cumulative submesoscale processes. In summer, a persistent and strong along-isobath jet acts as a dynamic barrier, effectively suppressing the exchange. These findings highlight the important role of topography in regulating surface material transport, and have important implications for predicting the advection and dispersion of plankton or oil spills over the continental shelf influenced by monsoon.

Hao, Dongliang

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Advanced Model Development for Large Eddy Simulation of Oxy-Combustion and Supercritical Carbon Dioxide Power Cycles

A joint experimental and numerical study is performed to observe the characteristics of a supercritical carbon dioxide turbulent mixing layer in the presence of strong nonlinearities in the thermodynamic and transport properties. A bespoke experimental setup is designed and employed for this purpose and provides insight into macroscopic mixing behavior. The mixing is experimentally observed using two techniques: shadowgraphy and spontaneous Raman scattering. Qualitative and quantitative intensity fields obtained via these techniques yield instantaneous and mean density data. Spanwise temperature data is also collected using analogue resistance temperature detectors. These measurements are used to quantify the level of mixed material within the field. The experimental data are supplemented by a companion high-fidelity numerical study. The numerical results are obtained through fully resolved, three-dimensional direct numerical simulation. The numerical dataset permits observation of the near-field mixing characteristics, which are difficult to measure experimentally due to the rapid dynamics and sharp thermophysical gradients in this area. Qualitative field visualizations are presented, followed by quantitative mixed material results and observations regarding thermodynamic property trends at select locations within the field. One-dimensional spectra of the turbulent kinetic energy and solenoidal dissipation are provided to observe the spectral characteristics of the flow. Reynolds stress anisotropy is analyzed graphically through anisotropy invariance maps (Lumley triangles). The mixing quantification, spectral data and anisotropy analysis of a flow at these thermodynamic conditions represent the main outcomes of the work.

20 FOSSIL-FUELED POWER PLANTS

Techno-Economic Evaluation of a 600MW Pumped Storage Hydropower Plant using the Pumped Storage Hydropower Valuation Tool

This paper presents a techno-economic evaluation of the proposed 600 MW, 8-hour Craig – Hayden pumped storage hydropower project using the U.S. Department of Energy’s Pumped Storage Hydropower Valuation Tool. The analysis integrates plant technical characteristics, regional grid conditions, and market-based operating assumptions to quantify stacked value streams from energy arbitrage, capacity, ancillary services, transmission congestion relief, and reliability. Both price taker and price influencer frameworks are applied to examine the impact of market participation and system interactions on lifecycle economic performance using Benefit - Cost Analysis and Multi - Criteria Decision Analysis. The results show that the price taker approach provides higher revenue estimates based on exogenous price signals, while the price influencer approach captures production cost savings, renewable curtailment reduction, and market price formation, yielding more conservative but system-representative outcomes. The study demonstrates the strategic value of long-duration PSH for enhancing operational flexibility, resource adequacy, and grid reliability in a high-renewable Western Interconnection.

Bhattacharyya, Arjun [ORNL] (ORCID:000900060976046

Method of making thin films of sodium fluorides and their derivatives by ALD

A method of making thin films of sodium fluorides and their derivatives by atomic layer deposition (“ALD”). A sodium precursor is exposed to a substrate in an ALD reactor. The sodium precursor is purged, leaving the substrate with a sodium intermediate bound thereon. A fluorine precursor is exposed to the bound sodium intermediate in the ALD reactor. The fluorine precursor is purged and a sodium fluoride film is formed on the substrate.

Mane, Anil U.

Hierarchical low Pt-loading “core-shell” electrocatalysts for the oxygen reduction reaction in fuel cells

The sluggish kinetics of the oxygen reduction reaction (ORR) hinder cost-effective polymer electrolyte fuel cells (PEFCs), which rely on scarce, expensive platinum-based electrocatalysts (ECs). Here, we present a novel synthesis method for ORR ECs achieving exceptional platinum utilization. The design features a hierarchical “multi-carbon” support comprising carbon nanoparticles interacting with graphene nanoplatelets as the “core”, encapsulated by a porous carbon nitride (CN) “shell”. This configuration promotes strong core/shell interactions and a bimodal active site distribution, consisting of chemically dispersed Pt and Ni single-atom complexes and PtNix alloy nanoclusters embedded in the CN shell. These advantages enable high activity and durability, achieving an ORR activity of 1.6 A mgPt−1 at 0.9 V vs. RHE-an order of magnitude higher than Pt/C (0.17 A mgPt−1). A proof-of-concept PEFC demonstrates a specific power of 12.0 kW gPt−1 at 0.60 V. This approach offers a significant step toward more efficient and sustainable PEFC technologies.

Pagot, Gioele [University of Padova, Italy]

Chronology of ungrouped achondrites Northwest Africa 11119 and 7325/8486: implications for early evolution of a heterogeneous crust on a differentiated planetesimal

The chronology of ungrouped achondrites provides key insights into the timeline of igneous activity in the early Solar System. Two ungrouped achondrites – Northwest Africa (NWA) 11119 (andesite-dacite) and NWA 8486 and its pair NWA 7325 (olivine gabbro) – are the focus of this study, where their chronologies are investigated using multiple high-resolution techniques. Here we report the lead-lead (207Pb-206Pb) and manganese-chromium (53Mn-53Cr) systematics of NWA 11119, as well as the 207Pb-206Pb systematics of NWA 8486 alongside aluminum-magnesium (26Al-26Mg) systematics for NWA 7325. The U-corrected 207Pb-206Pb ages of NWA 11119 and the combined ages of NWA 7325/8486 are 4566.4 ± 0.8 Ma and 4563.8 ± 1.9 Ma, respectively. Additionally, we report the 53Mn-53Cr age of NWA 11119 to be 4564.4 ± 2.5 Ma and the 26Al-26Mg age of NWA 7325/8486 to be 4563.1 ± 0.3 Ma. The formation of NWA 11119 requires partial melting of a (likely chondritic) source reservoir leading to eruption of Si rich, alkali depleted magmas, while NWA 7325/8486 likely formed from a chemically fractionated reservoir with superchondritic Al/Mg. The clear geochemical and isotopic similarities of these achondrites, combined with the chronology reported here, is suggestive of formation of these two ungrouped achondrites on a common parent body which likely formed in the inner Solar System and experienced early differentiation under reducing conditions. If these achondrites did share a parent body, it would suggest that primary asteroids in the early Solar System commonly produced mineralogically and geochemically heterogeneous crusts. While mineralogical and geochemical heterogeneity is known to exist in the (mostly mafic) crust of asteroid Vesta, our findings show that even more significant crustal heterogeneity (representing felsic and mafic compositions) may exist on other asteroids.

Cartwright, Julia [University of Leicester, UK]

Understanding Photovoltage Deficits in Electrochemically Grown Tin Sulfide (SnS) Thin-Film Photovoltaic Devices

Tin­(II) sulfide (SnS) is an earth-abundant semiconductor with a direct optical bandgap of ca. 1.1 eV, which makes it a promising absorber material for thin-film photovoltaic (PV) devices. However, existing devices have significant photovoltage deficits, which may be related to the anisotropic structure of the layered Herzenbergite SnS crystal structure. Here, we explore electrochemical deposition as a near room temperature path to oriented SnS crystal films on Mo and FTO substrates and employ vibrating Kelvin probe surface photovoltage (SPV) spectroscopy and J–V measurements to identify conversion losses in them. According to grazing-incidence X-ray diffraction and SEM, the SnS films consist of crystalline microplates with preferred orientation in the [111] and [001] directions. The bare SnS films produce only small and irreversible surface photovoltage signals, due charge trapping and recombination at the SnS surfaces, but addition of a CdS buffer layer lowers the charge recombination rate by 2 orders of magnitude and increases both the photovoltage and its reversibility due to the formation of a p-SnS/n-CdS junction. According to SPV, the FTO/SnS back interface (but not the Mo/SnS interface) forms a detrimental p–n junction that hinders hole transfer. Additional shunting through the relatively open microcrystal SnS layers and a lower conductivity of the FTO substrate explain the low power conversion efficiencies of the final devices (0.18 and 0.10% for the Mo and FTO substrates). Altogether, this work establishes a low-temperature path for the fabrication of crystalline SnS film-based solar cells and identifies the bottlenecks that limit high photoconversion efficiency.

deposition

In-Situ Visualization of a Growing Brittle Crack in Aluminum Oxynitride Using Synchrotron X-Rays and the Double-Cleavage Drilled Compression Geometry

Brittle fracture is difficult to study in situ due to the speed of a growing crack and the often-catastrophic nature of failure in brittle materials. As a result, the influence of microstructural considerations, such as orientation, grain boundary locations, and strain field, on the crack path remains poorly understood. Presented in this study is a method addressing this knowledge gap, which utilizes the double-cleavage drilled compression geometry to achieve quasi-stable fracture in aluminum oxynitride (AlON). Synchrotron X-ray micro-computed tomography is used to characterize the crack shape and length, while high-energy diffraction microscopy provides information on the strains, orientations, and shapes of grains in the microstructure surrounding the crack tip. During testing, the crack grew in discrete and irregular jumps while the fracture toughness falls within reported ranges. The crack in AlON is found to have no greater tendency to crack intergranularly as compared to transgranularly, and grains which are cracked transgranularly do not display a trend in orientation or stress when compared to those around which the crack followed a grain boundary. The high resolution of the crack path and microstructural data provides a path forward for modeling and understanding 3D brittle fracture.

Gorske, Sara F.

Echo state network for coarsening dynamics of charge density waves

An echo state network (ESN) is a type of reservoir computer that uses a recurrent neural network with a sparsely connected hidden layer. Compared with other recurrent neural networks, one great advantage of ESN is the simplicity of its training process. Yet, despite the seemingly restricted learnable parameters, ESN has been shown to successfully capture the spatial-temporal dynamics of complex patterns. Here we build an ESN to model the coarsening dynamics of charge-density waves (CDWs) in a semiclassical Holstein model, which exhibits a checkerboard electron density modulation at half-filling stabilized by a commensurate lattice distortion. The inputs to the ESN are local CDW order parameters in a finite neighborhood centered around a given site, while the output is the predicted CDW order of the center site at the next time step. Special care is taken in the design of couplings between hidden layer and input nodes to ensure lattice symmetries are properly incorporated into the ESN model. Since the model predictions depend only on CDW configurations of a finite domain, the ESN is scalable and transferrable in the sense that a model trained on dataset from a small system can be directly applied to dynamical simulations on larger lattices. Furthermore, our work opens avenues for efficient dynamical modeling of pattern formations in functional electron materials.

2-dimensional systems

Lessons learned from the development and implementation of a workforce training curriculum for advanced controls for high performance HVAC systems

Over the past decade, academic research on advanced controls has slowly transitioned into new software platforms, giving rise to various companies developing and deploying these innovative products, including solutions for light commercial HVAC systems. However, the current workforce remains widely unprepared to install, maintain and operate these systems, particularly complex software-based control platforms, as most workforce training programs still focus on traditional building automation for large commercial buildings. This paper presents the development and piloting of curriculum for three key types of professionals: ● Technicians (trade-level): installing and maintaining modern high-performance HVAC systems and controls ● Programmers (undergrad-level): developing and implementing advanced controls ● Engineers and energy professionals (undergrad/grad-level): managing and evaluating system performance We share details of the material developed including training videos, open-source software, instruction manuals. We also present the results of a pilot implementation of the training materials with real students.

Casillas, Armando

NOx mediated formation of ε – UO 3 during thermal decomposition of uranyl nitrate hexahydrate under static air conditions

The thermal decomposition of uranyl nitrate hexahydrate in air at temperatures of 650 – 800 °C is expected to yield α – U 3 O 8 through intermediate UO 3 phases. Here, n this study, Raman spectroscopy complimented by powder X-ray diffraction revealed the unexpected formation of ε – UO 3 as an accompanying phase during thermal decomposition of UNH at 700 °C under static air conditions. Experiments demonstrated that ε – UO 3 does not form during the initial ramp up stage nor during the high temperature heating period; but instead forms during the cooling stage between 250 – 400 °C. Additional experiments revealed that UNH initially decomposes through an amorphous UO 3 intermediate prior to α – U 3 O 8 formation. Attempts to bypass the U 3 O 8 precursor in the formation of ε – UO 3 were unsuccessful, supporting the necessity of U 3 O 8 (α – U 3 O 8 in this study) in the formation of ε – UO 3 . The observed phase evolution is proposed to result from the NOx species generated during UNH thermal decomposition, which create localized oxidizing conditions within the furnace under static air conditions. Furthermore, a predominantly phase pure ε – UO 3 was synthesized under static air conditions through the addition of an extra plateau at 250 °C during the cooling step. These findings demonstrate the importance of gas-phase chemistry and cooling conditions in uranium oxide phase evolution and provide additional insight into ε – UO 3 formation pathways.

Epsilon uranium trioxide