Search NASASearch

SEARCH · Search NASA

Results for “296000 -- Energy Planning & Policy-- Electric Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

921 records · Page 3

Power Lane County Electric Grid Handbook

In 2024, Lane Couty was selected to participate in the U.S. Department of Energy’s Energy to Community program. Through the program, National Laboratory researchers from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory, and the National Laboratory of the Rockies provide three years of technical assistance to Lane County and their project partners: the Center for Rural Livelihoods, Springfield Utility Board, and Emerald People’s Utility District. The project, named Power Lane County, aims to improve local electric system affordability, reliability and resilience in the face of natural hazards and potentially rising loads. The Power Lane County Electric Grid Handbook establishes a foundational understanding of the energy landscape and electric grid in Lane County to inform community engagement, education, and analysis in future project phases. This document synthesizes public data and utility and stakeholder engagement, including utility interviews to give the reader a comprehensive view of the challenges facing Lane County's electric system and the opportunities to address them

Electricity

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY

A Technical Evaluation of Self-Protection Dose Rates in U.S. Domestic Nuclear Security Policy

U.S. nuclear security policy uses radiation self-protection as a basis for reducing material attractiveness, but existing dose-rate criteria may not reflect the time scales of theft or sabotage. This report evaluates whether the commonly cited 1 Gy/h at 1 m criterion can plausibly cause adversary task failure during short-duration malicious acts.

Fritchie, Jacob Wesley [Sandia National Laboratori

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS

Smart Charging of Fleet and Personal Electric Vehicles through Joint Vehicle-to-Grid Optimization

As electric vehicle (EV) adoption accelerates, vehicle-to-grid (V2G) strategies offer advantages over unmanaged charging (V0G) by enhancing grid stability, reducing fleet operation costs, and supporting integration of variable generation resources. This research develops a day-ahead optimization framework linked with agent-based simulations to evaluate coordinated V2G participation by fleet and personal EVs under 5 energy-pricing settings in Austin, Texas. Three scenarios (V0G, fleet-only V2G, and joint-V2G) are examined, considering real-time price and grid profiles, health-damage costs, and operational constraints for both fleet and personal EVs. Results show how V2G scenarios shift fleet EV charging to mid-day while enabling strategic battery-discharge during evening peaks, mitigating grid stress and lowering EV energy costs. V2G delivers close to 80% energy-cost savings for a 2000-EV fleet in Austin on grid-stressed days, with 55% lower charging pollutant outputs. Joint-V2G amplifies system-level benefits by complementing fleet discharge, but smart-charging equipment costs can offset those benefits.

Electric vehicle

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN

From zonal to nodal capacity expansion planning: Spatial aggregation impacts on a realistic test-case

Solving power system capacity expansion planning (CEP) problems at realistic spatial resolutions is computationally challenging. Thus, a common practice is to solve CEP over zonal models with low spatial resolution rather than over full-scale nodal power networks. Due to improvements in solving large-scale stochastic mixed integer programs, these computational limitations are becoming less relevant, and the assumption that zonal models are realistic and useful approximations of nodal CEP is worth revisiting. Here, this work is the first to conduct a systematic computational study on the assumption that spatial aggregation can reasonably be used for ISO-scale CEP. By considering a realistic, large-scale test network based on the state of California with over 8000 buses, we find that well-designed small spatial aggregations can yield good approximations but that coarser zonal models may result in large distortions of investment decisions, e.g., capacity under-investment of up to 41% for the lowest resolution model considered.

24 POWER TRANSMISSION AND DISTRIBUTION

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

UNIFI Specifications for Grid-Forming Inverter-Based Resources: Version 3

The UNiversal Interoperability for grid-Forming Inverters (UNIFI) Consortium addresses fundamental challenges facing the integration of grid-forming (GFM) inverters in electric grids alongside rotating machines and other inverter-based resources (IBRs). This document defines a set of UNIFI specifications for GFM IBRs that provides requirements from both a power system level as well as functional requirements at the inverter level that are intended to provide means for the vendor-agnostic operation of GFM IBRs at any scale in electric power systems.

14 SOLAR ENERGY

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Measuring Climate and Water Risk across the Bulk Power System

As climate impacts increase and power systems transition to renewables, planners and operators need insights into climate risks to power generation and infrastructure to ensure reliable decision-making in the short and long-term. We present a standardized, consistent mechanism for utilities and system operators to evaluate the climate- and water-related risks of their current and future grid assets. Using a risk-based approach on the combined outcomes of high-fidelity climate drivers together with water and power system models, we examine the temperature and water availability impacts within the contiguous United States to power system assets at the water basin level in three different time periods and report resulting outcomes on lost capacity across different expansion scenarios and climate models. The results indicate that air temperature has the highest effect on derating. Changes in streamflow do not have a large impact on generation capacity at the national level. Electric sector buildout scenarios each have a unique regional risk profile, depending on the technology mix and total capacity, although risks from high temperatures are significant for both traditional and renewable energy generation. Stakeholders can use this approach to monitor effects of generation capacity losses and potential impacts as climate, generation mix, and infrastructure change.

24 POWER TRANSMISSION AND DISTRIBUTION

CO2 Handling & Electrolyzer Efficiency Scaling Evaluator

CHEESE is an interactive dashboard tool for estimating the performance and material requirements of carbon dioxide electrolysis systems. It helps users evaluate how electrode area, current density, product selectivity, gas flow, cell voltage, and the number of cells in a stack affect system operation. The dashboard provides simple and advanced modes so it can be used for both quick estimates and more detailed engineering analysis. Users can estimate product output, carbon dioxide use, electrical power, electrode area, gas and liquid flow rates, energy efficiency, material cost per test, and the effect of scaling from a single cell to a multi cell stack. It also includes tools for examining carbon balance, equipment durability, component replacement, and changes in performance over time. This is intended to help both academia and industry researchers who are either getting into CO2 electrolysis on lab-scale or are trying to establish a larger footprint. CHEESE presents results through tables, charts, and simplified cell and stack diagrams. It is intended to support research planning, experimental design, comparison of operating conditions, and early stage scale up studies.

Prajapati, Aditya [Lawrence Livermore National Lab

Electrode Erosion and Prefire Studies Towards Fusion Scale Pulsed Power

This study presents a comprehensive investigation of electrode erosion and discharge behavior in spark gap switches over long switching cycle lifetimes. Brass, copper–tungsten (CuW), and stainless steel electrodes are tested under controlled conditions to quantify material degradation, debris accumulation, and changes in breakdown voltage. High-resolution imaging and statistical analysis of spark channel locations and gap breakdown voltages reveal how surface evolution influences long-term performance and reliability. These results provide essential data for lifetime modeling and inform design strategies for pulsed power systems in emerging applications such as private sector fusion energy and large-scale facilities like Sandia’s Z Machine and proposed ZX upgrades, where high repetition reliability and predictable behavior are critical.

electrical breakdown

Tracing U.S. fuel life-cycle greenhouse gas emissions in a multi-sector dynamics model using LC-GCAM

Model-based analysis of fuel pathways is essential for informing energy and environmental policy. Two major model types are typically used: multi-sector dynamics models, which capture the broader energy-economy, such as GCAM (Global Change Analysis Model), and life cycle assessment models, such as GREET (Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation). Each has distinct strengths and limitations, and recent studies increasingly adopt hybrid approaches to harness the advantages of both. However, such integration is often time-consuming and complicated by inconsistencies in system boundaries and technology definitions. We present LC-GCAM, a new tool that enables estimation of life-cycle greenhouse gas emissions and primary energy use for any fuel pathway represented in GCAM. We apply LC-GCAM to 300 scenarios designed to explore key uncertainties affecting the life-cycle performance of future fuel options in the U.S. freight sector. To evaluate LC-GCAM, we compare its results with those from GREET for nine fuel types in a 2030 reference scenario. When input assumptions are modestly aligned, LC-GCAM and GREET estimates typically agree within 10% (absolute sum-based mean absolute percentage error). LC-GCAM offers a flexible and efficient approach to generating life-cycle metrics within an integrated modeling framework, supporting robust policy analysis across a wide range of interacting energy system uncertainties.

Wolfram, Paul

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)

Integrated Magnetics for Multiport Inductive and Conductive Power Transfer Architecture for Electric Vehicles

This paper proposes a shared magnetic arrangement for an electric-vehicle charger that supports both conductive and inductive charging while preserving independent power control at the two ports. In the proposed implementation, the high-frequency transformer used for the conductive path and the resonant inductor required by the inductive path are realized in an integrated form. By combining the magnetic structure and primary-side converter hardware, the charger can deliver improved hardware utilization and higher power density without a corresponding increase in cost or implementation complexity. The paper describes the magnetic realization and presents finite-element and circuit-level simulation results to confirm minimal interaction between the two charging paths. The study demonstrates that the proposed charger is a viable option for flexible, high-power EV charging systems.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)

Next-Generation Energy Technologies for Connected and Automated On-Road Vehicles (NEXTCAR) - Predictive Data-Driven Vehicle Dynamics and Powertrain Control: from ECU to the Cloud (Final Scientific/Technical Report)

This project developed and demonstrated a predictive, data-driven vehicle control system designed to improve energy efficiency and driving performance. The team created intelligent self-driving car technology that optimizes fuel and electricity use by proactively planning vehicle actions. By combining Level 4 autonomous driving capabilities with vehicle-to-everything (V2X) connectivity, the system enables vehicles to adjust speed and change lanes in response to traffic signals, surrounding vehicles, and road conditions, reducing unnecessary stops and delays. In testing, the system improved vehicle fuel economy by more than 30% and reduced travel time by approximately 10%, compared to a conventional adaptive cruise control baseline. These results demonstrate the technical effectiveness of using predictive, V2X-enabled strategies, such as traffic light timing and surrounding traffic awareness, to inform real-time vehicle powertrain control and driving behavior. Additionally, a supporting cloud platform was developed to provide dispatch and route recommendations as well as to log vehicle data, demonstrating the economic feasibility of this approach at the fleet level. By optimizing dispatching and routing operations, this technology enables electric fleet operators to use their vehicles more efficiently and reduce reliance on diesel backups, lowering both operating costs and energy consumption. Overall, this project’s technology advances the future of clean, energy-efficient transportation, enabling vehicles and fleets to reduce energy waste, cut costs, and lower emissions through intelligent automation and connectivity.

33 ADVANCED PROPULSION SYSTEMS