Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARAMETRIC DIODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Computer acquired performance data from an etched-rhenium, molybdenum planar diode

Performance data from an etched-rhenium, molybdenum thermionic converter are presented. The planar converter has a guard-ringed collector and a fixed spacing of 0.254 mm (10 mils). The data were acquired by using a computer and are available on microfiche as individual or composite parametric current, voltage curves. The parameters are the temperatures of the emitter T sub E, collector T sub C and cesium reservoir T sub R. The composite plots have constant T sub E, and varying T sub C or T sub R, or both. The envelope and composite plots having constant I sub E are presented. The diode was tested at increments between 1500 and 2000 K for the emitter, 750 and 1100 K for the collector, and 540 and 640 K for the reservoir. In all, 774 individual current, voltage curves were obtained.

Manista, E. J.↗

Tunable solid-state lasers - An emerging technology for remote sensing of planetary atmospheres

The present development status and prospective (1990s) performance-improvement evaluation of tunable solid-state laser technology notes recent trends toward spectrum coverage over the 0.20-14.0 microns range, in addition to dramatic increases in efficiency, service life, and reliability. It is judged that the Ti:Al2O3 laser and the AgGaSe2 optical parametric oscillator pumped by a Ho:YAG laser could cover the near-IR and mid-IR regions of the spectrum. Laser diodes operating at 0.78 microns should provide an excellent pump for a Ho:YAG laser.

Barnes, Norman P.↗

Lidar Measurements of Methane and Applications for Aircraft and Spacecraft

Atmospheric methane levels have remained relatively constant over the last decade around 1.78 parts per million (ppm) but observations since 2007 show that levels may be increasing. This trend may be caused by increased fossil fuel production, rice farming, livestock and landfills, but the underlying causes are quite uncertain. One hypothesis is that reservoirs of carbon trapped in the permafrost regions of northern Canada, Europe, and Siberia thaw as global temperatures rise and are releasing increasing amounts of methane. Another hypothesis points to increased production of methane by microbes as the permafrost warms. Currently most observations of greenhouse gases are limited to in-situ (surface and tower sites) and limited airborne in-situ measurements. Space column density measurements are starting to become available from the GOSAT mission. Although methane survives for a shorter time in the atmosphere than CO2, its impact on climate change per molecule is about 23 times than that of CO2. Accurate global observations of several greenhouse gases, including methane, are urgently needed in order to better understand climate change processes and to reduce the uncertainty in the carbon budget. Differential absorption lidar is a well-established technique to measure atmospheric gases, and methane has optical absorption bands near 1.65,2.2,3.4 and 7.8 micron. The near infrared overtones lines of CH4 near 1650 nm are relatively free of interference from other species. There are absorption lines near 1651 nm which are both temperature insensitive and have line strengths well suited for lidar measurements. We have developed a laser and demonstrated lidar measurements of CH4 using lines in this band. Our laser uses a narrow linewidth 1064 nm laser pulse passing through a nonlinear crystal. We generate the tunable laser signals near 1651 nm by using the optical parametric amplification (OPA) process. Inside the crystal the 1064 nm beam overlaps with an injection seed laser near 1651 nm from a wavelength tunable diode laser. Incident photons from the pump laser pulse are converted into two photons, with one at the wavelength of the injection seeder. The wavelength of the OPA output is tuned via the wavelength of diode laser. Our laser is tunable, operates near 1651 nm and generates approximately 4 uJ/pulse at 6 KHz. We vary the emission wavelengths within this band by tuning the diode laser's wavelength. We have used this OPA transmitter to make measurements of CH4 at various pressures in a gas cell and over open outdoor horizontal paths. We have measured the lineshape of methane in a 6 cm long cell at various energy levels with this transmitter, with excellent agreement with the lineshape calculated by HITRAN. We have also measured the absorption lineshape of atmospheric methane in an open 3 km outdoor path. The agreement between the measurements and HITRAN, for 1746 ppb and 760 Torr was quite good. We have also made pulsed two wavelength lidar measurements of methane line absorption in the column to a tower at 1.5 km range. These used on- and off-line wavelengths of 1650.957 nm, and 1651.072 nm, and a 20 cm diameter receiver telescope with an infrared PMT detector. The absorption of the on-line photons was 30%. The methane column absorption was estimated via HITRAN, and was in good agreement with the expected methane absorption for a concentration of 1750 ppm. Finally we have calculated the measurement performance of an airborne methane lidar using this transmitter, as well as the energy and telescope scaling needed for a lidar for space. These results, and more details of our experiments will be described in the presentation.

Riris, Haris↗

Injection-seeded operation of a Q-switched Cr,Tm,Ho:YAG laser

Single-frequency Tm,Ho:YAG lasers operating near 2 microns are attractive sources for several applications including eye-safe laser radar (lidar) and pumping of AgGaSe2 parametric oscillators for efficient generation of longer wavelengths. As part of a program to develop a coherent lidar system using Tm,Ho:YAG lasers, a diode laser-pumped tunable CW single-longitudinal-mode (SLM) Cr:Tm:Ho:YAG laser and a flashlamp-pumped single-transverse-mode Q-switched Cr,Tm,Ho:YAG laser were developed. The CW laser was used to injection-seed the flashlamp-pumped laser, resulting in SLM Q-switched output. Operational characteristics of the CW and Q-switched lasers and injection-seeding results are reported.

Henderson, Sammy W.↗

Computer acquired performance data from a chemically vapor-deposited-rhenium, niobium planar diode

Performance data from a chemically vapor-deposited-rhenium, niobium thermionic converter are presented. The planar converter has a guard-ringed collector and a nominal fixed spacing of 0.25 mm (10 mils). The data were obtained by using a computerized acquisition system and are available on request to one of the authors on microfiche as individual and composite parametric current, voltage curves. The parameters are the temperatures of the emitter T sub E collector T sub C, and cesium reservoir T sub R. The composite plots have constant T sub E and varying T sub C or T sub R, or both. Current, voltage envelopes having constant T sub E with and without fixed T sub C appear in the present report. The diode was tested at increments between 1600 and 2000 K for the emitter Hohlraum, 800 to 1100 K for the collector, and 540 and 650 K for the reservoir. A total of 312 current, voltage curves were obtained in the present performance evaluation. Current, voltage envelopes from three rhenium emitter converters evaluated in the present program are also given. The data are compared at commom emitter Hohlraum temperatures.

Manista, E. J.↗

Trace Gas Measurements on Mars and Earth Using Optical Parametric Generation

Trace gases and their isotopic ratios in planetary atmospheres offer important but subtle clues as to the origins of a planet's atmosphere, hydrology, geology, and potential for biology. An orbiting laser remote sensing instrument is capable of measuring trace gases on a global scale with unprecedented accuracy, and higher spatial resolution that can be obtained by passive instruments. We have developed an active sensing instrument for the remote measurement of trace gases in planetary atmospheres (including Earth). The technique uses widely tunable, seeded optical parametric generation (OPG) to measure methane, CO2, water vapor, and other trace gases in the near and mid-infrared spectral regions. Methane is a strong greenhouse gas on Earth and it is also a potential biogenic marker on Mars and other planets. Methane in the Earth's atmosphere survives for a shorter time than CO2 but its impact on climate change can be larger than CO2. Methane levels have remained relatively constant over the last decade around 1.78 parts per million (ppm) but recent observations indicate that methane levels may be on the rise. Increasing methane concentrations may trigger a positive feedback loop and a subsequent runaway greenhouse effect, where increasing temperatures result in increasing methane levels. The NRC Decadal Survey recognized the importance of global observations of greenhouse gases and called for simultaneous CH4, CO, and CO2 measurements but also underlined the technological limitations for these observations. For Mars, methane measurements are of great interest because of its potential as a strong biogenic marker. A remote sensing instrument that can measure day and night over all seasons and latitudes can identify and localize sources of biogenic gas plumes produced by subsurface chemistry or biology, and aid in the search for extra-terrestrial life. It can identify the dynamics of methane generation over time and latitude and identify future lander mission sites for more detailed in-situ analysis. In this paper we report on remote sensing measurements of methane using a high peak power, widely tunable optical parametric generator (OPG) operating at 3.3 micron and 1.65 micron. The OPG is pumped by a passively q-switched single frequency laser (3ns, 5KHz, 50uJ) and seeded by a diode laser. The spectral width of both signal and idler of seeded OPG is nearly Fourier transform limited. The output of seeded OPG is single frequency with high spectral purity and is widely tunable. Both 1650 nm and 3300 nm can be generated with a conversion efficiency of more than 30%. We have demonstrated detection of methane at 3274 nm and 1650 nm in a cell and also performed open path atmospheric measurements of methane at the same wavelengths. Finally, we were able to demonstrate simultaneous detection of methane at 3270.4 nm and CO2 at 1578.2 nm. In this paper we will discuss the OPG performance and atmospheric open path measurement results.

Numata, Kenji↗

Diode step stress program for JANTX1N649-1

The effect of power/temperature step stress when applied to a variety of semiconductor devices is evaluated. A total of 48 samples were submitted to be processed. Control sample units were maintained for verification of the electrical parametric testing. The test circuit was used to power all of the test devices during the power/temperature stress conditions.

Source record↗

6 um Pulsed OP-GaAs OPO Laser for Unambiguous Water Ice Detection on the Moon and Other Planetary Bodies

NASA demands a laser transmitter for planetary remote sensing to detect water-ice on the Moon and other planetary bodies. Based on the measurement of the Moon Mineralogy Mapper (M3) instrument, the discovery of water ice on the Moon was acclaimed, but the measurement is disputed because OH- and/or H2O-bearing materials share the absorption line around 3 μm wavelength. Lunar Flashlight, another mission project exploring the surface of Moon which will be launched later this year, enables to map the minerals on dark area of the Moon, but could not resolve the above-mentioned ambiguity. The absorption of 6.08 μm light is uniquely associated with the bending resonance of H2O since there is no comparable vibration in confounding OH-bearing materials. 6.08 μm laser between the atmospheric windows: middle-wave infrared (3-5 μm) and long-wave infrared (8-12 μm) has not been commercially available. Our approach is a Q-switched Ho:YLF laser pumped the orientation-pattern Gallium Arsenide optical parametric oscillator (OP-GaAs OPO) for generating high-energy laser pulses at the wavelength of 6.08 μm. In the current design, a 1.94 μm Tm:fiber is used as the pump source. In the compact design, a 1.94 μm laser diode will replace the Tm:fiber laser as the pump source. We will combine this proposed mid-infrared laser with the latest HgCdTe avalanche photodiode (APD) array to design a lidar for detecting water ice on the Moon and Mars from their respective orbits, enabling novel science and in-situ resource utilization. Our instrument is an enabling technology aboard the Artemis program and others.

mid-infrared laser↗

Experimental generation of polarization entanglement from spontaneous parametric down-conversion pumped by spatiotemporally highly incoherent light

Here, we investigate the cross influence of the pump coherence on the entanglement produced from spontaneous parametric down-conversion (SPDC) in different degrees of freedom (DOFs). We experimentally demonstrate the generation of polarization entanglement from SPDC pumped by a spatiotemporally highly incoherent (STHI) light-emitting diode. Our quantum state tomography measurements using multimode collection fibers to avoid postselection yield a two-qubit state with the concurrence of 0.531 ± 0.006 and purity of 0.647 ± 0.005, in excellent agreement with our theoretically predicted concurrence of 0.552 and purity of 0.652. We find that using an STHI pump reduces the entanglement and purity of the output polarization two-qubit state due to a coupling between the spatiotemporal and polarization DOFs introduced by the birefringence and dispersion of the nonlinear crystal. The viability of SPDC with STHI pumps is important for two reasons: (i) STHI sources are ubiquitous and available at a wider range of wavelengths than lasers, and (ii) the generated STHI polarization-entangled two-photon states could potentially be useful in long-distance quantum communication schemes due to their robustness to scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient monolithic MgO:LiNbO3 singly resonant optical parametric oscillator

A monolithic MgO:LiNbO3 singly resonant optical parametric oscillator (OPO) was operated as both a standing-wave and a ring-geometry resonator. The OPO was pumped by the second harmonic of an amplified single-mode diode-laser-pumped Nd:YAG laser. Pump depletions of greater than 60 percent were observed when pumping four times greater than the 35-W threshold. The OPO output at the resonant signal tuned with temperature from 834 to 958 nm, while the corresponding idler tuned from 1.47 to 1.2 microns. The spectral characteristics of the OPO signal output and the relative merits of a standing wave versus a ring geometry are discussed.

Kozlovsky, W. J.↗

The Implications of Collisions on the Spatial Profile of Electric Potential and the Space-Charge-Limited Current

The space-charge-limited current (SCLC) in a vacuum diode is given by the Child-Langmuir law (CLL), whose electric potential ϕ(x) ∝ (x/D) 4/3 , where x is the spatial coordinate across the gap and D is the gap separation distance. For a collisional diode, SCLC is given by the Mott-Gurney law (MGL) and ϕ(x) ∝ (x/D) 3/2 . Here, we apply a capacitance argument for SCLC and use the transit time from a recent exact solution for collisional SCLC to show that ϕ(x) ∝ (x/D)ξ for a general collisional gap, where 4/3 ≤ ξ ≤ 3/2 . Furthermore, ξ is strictly a function of νT, where ν is the collision frequency and T is the electron transit time. Using this definition of ξ, we estimate the spatial dependence of the electron velocity and use the gap capacitance to derive an analytic equation for collisional SCLC that agrees within ~4.5% of the exact solution that requires solving parametrically through T. This analytic equation for general ξ asymptotically recovers the CLL as ν → 0 and the MGL as ν → ∞. As a result, matching these limits shows that ξ ≈ 1.40 and V ∝ D 2 ν 2 at the transition from a vacuum to a collisional diode for any device condition.

Anodes↗

Diode step stress program for JANTX1N2970b

Data for the purpose of evaluating the effect of power/temperature step stress was studied when applied to the zener diode JANTX1N2970B manufactured by Siemens and General Semiconductor, Inc. A total of 48 samples from each manufacturer was submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. The tests for determining power/temperature stresses are described, and test results are discussed. Failure analyses for power stress, and temperature stress are presented.

Source record↗

Diode step stress program for JANTX1N1202A

Power/temperature step stress was applied to the switching diode JANTX1N1202A manufactured by General Electric and International Rectifier. A total of 48 samples from each manufacturer was submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. All test samples were subjected to the electrical tests after completing the prior power/temperature step stress point. Results are given.

Source record↗

Diode step stress program for JANTX1N3893

Data for the purpose of evaluating the effect of power/temperature step stress on the diode JANTX1N3893 manufactured by Siemens and Motorola is presented. A total of 48 samples from each manufacturer were submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

Diode step stress testing program for JANTX1N3016B

The effect of power/temperature step stress when applied to a variety the zener diode JANTX2N3016B manufactured by Siemens and Motorola is reported. A total of 48 samples from each manufacturer was submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

Diode step stress testing program for JANTX1N3031B

The effect of power/temperature step stress when applied to the zener diode JANTX1N3031B manufactured by Siemens and Motorola is reported. A total of 48 samples from each manufacturer was submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

Diode step stress program for JANTX1N5615

The effect of power/temperature step stress when applied to the switching diode JANTX1N5615 manufactured by Semtech and Micro semiconductor was examined. A total of 48 samples from each manufacturer were submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. All test samples were subjected to the electrical tests after completing the prior power/temperature step stress point. Results are presented.

Source record↗

Diode step stress testing program for JANTX1N5618

The effect of power/temperature step stress when applied to the switching diode JANTX1N5618 manufactured by Semtech and Micro Semiconductor is reported. A total of 48 samples from each manufacturer was submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗