Search NASA⌕ Search

SEARCH · Search NASA

Results for “real time detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evaluation of Three RNA Extraction Kits with a 2019-nCoV Assay

The following characteristics of three RNA extraction kits (Norgen Biotek Total RNA Purification Kit, #17200; Bioneer AccuPrep Viral RNA Extraction Kit, #K-3033; and Promega Maxwell HT Viral TNA Kit, #AX2340) were evaluated: Limits of detection for quantitative synthetic RNA using the Centers for Disease Control and Prevention’s (CDC) 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel and the Applied Biosystems 7500 Fast Dx system; Limits of detection for positive clinical specimen using the Centers for Disease Control and Prevention’s (CDC) 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel and the Applied Biosystems 7500 Fast Dx system; Ability of the lysis buffers in each kit to inactivate the virus as measured by a cell-based infectivity assay.

60 APPLIED LIFE SCIENCES↗

On the novel 3-D neutron transport kinetic tRAPID algorithm and its validation

The Real-time Analysis for Particle-transport and In-situ Detection (RAPID) Code System, based on the Multi-stage Response-function Transport (MRT) methodology, allows for real-time simulation of nuclear systems based on 3-D continuous-energy particle transport. RAPID's steady-state (criticality) neutron transport algorithm is based on the Fission Matrix (FM) method, and has been extensively verified and validated against computational benchmarks and experiments. This paper introduces the novel 3-D time-dependent transport algorithm that has been implemented into the code, tRAPID, and its validation using the JSI TRIGA Mark-II reactor. tRAPID accurately and efficiently calculates neutron kinetics parameters (such as β{sub eff}, l{sub eff} , Λ, α{sub Rossi}) and 3-D time-dependent neutron fission source distribution and neutron importances for both prompt and delayed neutrons. tRAPID is used to simulate a rod insertion experiment performed at the JSI TRIGA Mark-II reactor, during which signals from four fission chambers at four different locations in the core were collected. The results demonstrate how tRAPID is capable of calculating detailed and accurate results with only a minimal use computational resources and time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Failure diagnosis and trend‐based performance losses routines for the detection and classification of incidents in large‐scale photovoltaic systems

Abstract Fault detection and classification in photovoltaic (PV) systems through real‐time monitoring is a fundamental task that ensures quality of operation and significantly improves the performance and reliability of operating systems. Different statistical and comparative approaches have already been proposed in the literature for fault detection; however, accurate classification of fault and loss incidents based on PV performance time series remains a key challenge. Failure diagnosis and trend‐based performance loss routines were developed in this work for detecting PV underperformance and accurately identifying the different fault types and loss mechanisms. The proposed routines focus mainly on the differentiation of failures (e.g., inverter faults) from irreversible (e.g., degradation) and reversible (e.g., snow and soiling) performance loss factors based on statistical analysis. The proposed routines were benchmarked using historical inverter data obtained from a 1.8 MWp PV power plant. The results demonstrated the effectiveness of the routines for detecting failures and loss mechanisms and the capability of the pipeline for distinguishing underperformance issues using anomaly detection and change‐point (CP) models. Finally, a CP model was used to extract significant changes in time series data, to detect soiling and cleaning events and to estimate both the performance loss and degradation rates of fielded PV systems.

14 SOLAR ENERGY↗

Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-infrared wavelength bands. Our system retains much of the core signal processing architecture from the first generation system but with a significantly higher bandwidth, enabling the readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 GHz–8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below −30 dBc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online data-driven changepoint detection for high-dimensional dynamical systems

In this study, the detection of anomalies or transitions in complex dynamical systems is of critical importance to various applications. In this study, we propose the use of machine learning to detect changepoints for high-dimensional dynamical systems. Here, changepoints indicate instances in time when the underlying dynamical system has a fundamentally different characteristic—which may be due to a change in the model parameters or due to intermittent phenomena arising from the same model. We propose two complementary approaches to achieve this, with the first devised using arguments from probabilistic unsupervised learning and the latter devised using supervised deep learning. To accelerate the deployment of transition detection algorithms in high-dimensional dynamical systems, we introduce dimensionality reduction techniques. Our experiments demonstrate that transitions can be detected efficiently, in real-time, for the two-dimensional forced Kolmogorov flow and the Rössler dynamical system, which are characterized by anomalous regimes in phase space where dynamics are perturbed off the attractor at potentially uneven intervals. Finally, we also demonstrate how variations in the frequency of detected changepoints may be utilized to detect a significant modification to the underlying model parameters by utilizing the Lorenz-63 dynamical system.

97 MATHEMATICS AND COMPUTING↗

MSU IETC ML for Modbus (AN EDGE)

This study explores machine learning for decoding Modbus RTU data using K-Nearest Neighbors (KNN) models. An initial KNN model trained on 8,000 packets achieved 95.15% accuracy. Although ML improves generalization, accuracy still falls short of deterministic methods. These findings have implications for Modbus traffic analysis, intrusion detection in industrial networks, and adaptive error correction in real-time monitoring systems. By refining ML-based decoding, future work could enable more efficient anomaly detection and predictive maintenance in industrial automation and cybersecurity applications.

Communication Protocol↗

An experimental and chemical kinetic modeling study of 4-butoxyheptane combustion

Here, the combustion kinetics of a novel oxygenated bioblendstock for diesel, 4-butoxyheptane (4-BH), was investigated experimentally using a flow reactor and a heated, high-pressure shock tube. The flow reactor experiments employed oxygen as the oxidizer and helium as the diluent with oxidation conducted at atmospheric pressure and 10 bar for temperatures from 400 to 1000 K at 20-K intervals. The fuel, oxidizer, and diluent flow rates were varied at different temperatures to maintain a constant initial fuel mole fraction of 1000 ppm, with stoichiometric equivalence ratio, and a residence time of 2.0 s. The reacted gas was fed to two separate GC systems that could qualitatively and quantitatively detect product species. Additionally, real fuel-air ignition delay time (IDT) data were collected using a heated, high-pressure shock-tube facility. Fuel lean (φ = 0.5) and stoichiometric (φ = 1.0) mixtures were investigated at 10 atm as well as at 30 atm for the fuel lean case for temperatures between 847 and 1259 K. A detailed chemical kinetics mechanism was developed to model the product distribution from the flow reactor and IDTs from the shock tube. The proposed model was able to predict the double NTC behavior in flow reactor experiments reasonably well. Model predictions at low temperatures were observed to be highly sensitive to the rate constants of ketohydroperoxide (KHP) decomposition in the case of the OOH group in α position which were modeled based on existing literature studies on ethers. It was noted that in the absence of theoretical or experimental studies, the rate constants for KHP decomposition used in the literature were empirically set. Additional studies are required to address the gap in model prediction obtained in this study and to reduce the uncertainty in kinetics models for ether oxidation. Predicted product concentrations and IDTs showed some quantitative agreement with experimental data, but the overall reactivity of the IDTs is underpredicted. Additionally, significant deviation is observed for the IDT results at 10 atm for the stoichiometric case with minor deviations for the other cases. The reaction pathways to the missing products were then further analyzed theoretically through quantum-mechanical calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation Plan for Combined Heat and Power Systems VOLTTRON Controller: Performance Monitoring and Real-Time Commissioning Algorithm Verification

Building-integrated cooling, heating, and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV, and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of clean, efficient, reliable, and affordable next-generation integrated energy system. Previous report listed the components for which PM, real-time CxV, and AFDD algorithms will be developed, how the algorithms will be tested, and the metrics that will be used to validate the algorithms and their ease of deployment. Deployment of these algorithms in the field will result in a reduction in energy consumption of between 10% and 20% (for both CHP and conventional building systems). This report builds upon the previous report by detailing the process by which PNNL will implement performance monitoring and real-time commissioning algorithms for CHP systems in conjunction with the use of the VOLTTRON CHP economic dispatch agent in host facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Design and Evaluation of Zero Trust Architecture for Electric Vehicle Charging Infrastructure: EVs @ Scale Series on EV Charging Station Cybersecurity

Implementing a zero trust architecture can significantly bolster the security of electric vehicle (EV) charging infrastructure. EV charging infrastructure includes numerous networked interfaces, each of which can present potential vulnerabilities. When these vulnerabilities are exploited, they can compromise the entire system, leading to severe operational and security risks. Zero trust is a security model that operates on the principle of "never trust, always verify," which helps manage the attack surface and limit the scope of any potential compromises. Fundamentally, this model ensures that no entity, whether inside or outside the network, is trusted by default. The design principles of zero trust include continuous verification, strict deny-by-default access controls, and micro-segmentation. Continuous verification ensures that every request is thoroughly checked, regardless of its origin. Strict access controls enforce the principle of least privilege, allowing users and devices only the minimum necessary access to perform their functions. Micro-segmentation involves dividing the network into smaller, isolated segments to prevent lateral movement in case of a breach. In the context of EV charging infrastructure, zero trust can be implemented through various strategies. For example, multi-factor authentication (MFA) can be required for engineers to access the management interfaces and control systems of charging stations. Real-time monitoring and analysis of network traffic can help detect and respond to anomalies. Systems that do not need to communicate with each other can be micro-segmented to enhance security. All communications should adhere to predefined policies to be permitted. Additionally, encrypting communications can protect sensitive information exchanged between chargers and management systems. This paper presents a zero trust architecture specifically designed for EV charging infrastructure. Implementing zero trust not only mitigates risks but also builds a resilient infrastructure capable of withstanding and quickly recovering from cyber threats. The architecture addresses six defined security objectives. A comprehensive test plan is developed to assess the architecture against these objectives, and the results of the evaluation are reported. This approach is essential for maintaining the reliability and integrity of EV charging services in an increasingly interconnected and vulnerable digital landscape. This is the first in a planned series of papers exploring the implementation of zero trust in EV charging infrastructure. Each paper will delve into different aspects and applications of zero trust, highlighting how various work processes and requirements can lead to distinct architectural designs. These architectures will be tailored to address specific security challenges and operational needs within the EV charging ecosystem, ensuring a robust and adaptable security framework.

33 ADVANCED PROPULSION SYSTEMS↗

Infrastructure-Based Cooperative Perception at a Traffic Intersection: Overview and Challenges: Preprint

Recent advancement in autonomous driving vehicles and V2X communication has attracted increasing attention towards Intelligent Transportation Systems to build a safe and reliable traffic intersection. However, most of the systems are still at the initial stages and require significant progress to become a reality. This paper presents an overview of NREL Infrastructure Perception and Control (IPC) framework which is an open-source track-data fusion engine which takes input from infrastructure-based perception sensors and cooperatively shared messages from Connected Autonomous Vehicles (CAVs) and Connected Vehicle (CVs) and the challenges associated with deploying such cooperative perception framework at a four-way traffic intersection in the city of Colorado Springs, CO, USA. The sensor data is collected by deploying two radars and two LiDAR sensors on the IPC mobile lab and two radars on diagonally opposite traffic poles at the proposed intersection. The sensor output results imply the need for rapid sensor calibration to bring the collective perception to a common coordinate frame, the importance of time synchronization between the sensors in order to capture accurate spatial and temporal alignment of the objects, and the need for a health monitoring system with fail safe closed-loop detection model for real-time deployment.

camera↗

Anomaly Detection and Mitigation in FACTS-based Wide-Area Voltage Control Systems using Machine Learning

With the increasing deployment of Flexible AC Transmission System (FACTS) devices in wide-area voltage control systems (WAVCS) for achieving improved voltage stability of bulk power systems, the possibility for cyber attacks on these systems is also increasing. Successful stealthy cyber attacks that are difficult to detect by traditional informational technology (IT)-based cybersecurity solutions or threshold-based bad data detectors can lead to a voltage collapse in power grid. This paper presents the testbed-based attacks implementation and real-time evaluation of machine learning (ML) algorithm for detecting and mitigating stealthy cyber attacks on FACTS-based WAVCS on a hardware-in-the-loop (HIL) testbed. Initially, we discuss the implementation of a fuzzy logic controller (FLC) that controls a Static VAR Compensator (SVC) device deployed in a two-area four-machine Kundur power system for improving transient voltage stability. Later, the ML-based Anomaly Detection and Mitigation (ADM) system is implemented on the cyber-physical HIL testbed to detect and mitigate various stealthy cyber attacks, which are injected in real-time over the wide-area network (WAN). The experimental results show accurate and effective performance of ADM system in detecting and mitigating anomalies while keeping the grid stable and within the system operating limits, as defined by the North America Electric Reliability Corporation (NERC).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interpreting Forced Oscillation Notifications from ESAMS: General Guidance for Reliability Coordinators

The Eastern Interconnection Situational Awareness Monitoring System (ESAMS) project demonstrated the feasibility of aggregating synchrophasor measurements from across an interconnection, analyzing them, and providing real-time wide-area situational awareness to system operators who may have excellent visibility within their footprint but lack an interconnection-wide view. An application within ESAMS that has garnered industry interest involves detecting forced oscillations visible across multiple areas, identifying the region where the oscillation originated from, quantifying the uncertainty in source localization results, and notifying users in real-time if the detected oscillation amplitudes cross a specified threshold. It is expected that system operators will utilize their internal SCADA/EMS/synchrophasor systems in conjunction with information provided by ESAMS to take effective mitigation actions if forced oscillation notifications are received. This report provides some general guidance on how the ESAMS information can be used for source localization and coordination among multiple reliability coordinators; and also identifies potential enhancements to ESAMS notifications for improved interpretability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electropotential Verification for Nuclear Safeguards

The international safeguards regime desires methods to efficiently verify that facilities are only performing declared activities. Electropotential verification (EPV) is a newly proposed technique that was tested for its feasibility to perform facility design information verification (DIV). EPV works by passing a constant, low voltage current through a conductive system (facility infrastructure of nuclear fuel assembly) and measuring the resulting voltage at various places throughout the infrastructure in order to establish a baseline. Changes made to the system affect these voltage readings, which will deviate from the baseline and indicate that a change to the system was made. For large scale infrastructure such as a nuclear facility DIV, it appears feasible that changes in configuration of the system’s grounding can be detected in real-time, and the location of the change can be inferred from the measured intensity of the change in voltage.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Electropotential Verification for Nuclear Safeguards

The international safeguards regime desires methods to efficiently verify that facilities are only performing declared activities. Electropotential verification (EPV) is a newly proposed technique that was tested for its feasibility to perform facility design information verification (DIV) and verification of spent nuclear fuel while in a cooling pool. EPV works by passing a constant, low voltage current through a conductive system (facility infrastructure of nuclear fuel assembly) and measuring the resulting voltage at various places throughout the infrastructure in order to establish a baseline. Changes made to the system affect these voltage readings, which will deviate from the baseline and indicate that a change to the system was made. For facility DIV, it appears feasible that changes in configuration of the system’s grounding can be detected in real-time, and the location of the change can be inferred from the measured intensity of the change in voltage. Determination of whether or not spent fuel was present in a fuel rod, as well as the presence/absence of a fuel rod from an assembly using EPV, proved unsuccessful with the sensitivity of instrumentation used in this study.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

System and method using in-situ electromagnetic diagnostic for real-time projectile characterization

The present disclosure relates to a system for detecting characteristics of a moving element. The system may include a tubular housing having a tubular first portion having a first end and a second end, with the first end forming an input port and the second end forming an output port. A source of wireless electromagnetic energy projects a wireless electromagnetic energy signal, travelling in a first direction, into the input port and through an interior area defined by the tubular first portion. A signal processing subsystem detects at least one characteristic of the signal after the signal is reflected back to the first end after having interacted with the element as the element moves past the output port of the housing.

Chang, Tammy↗

PMU Data Quality and Sensor Health Monitoring

Phasor Measurement Units (PMUs) play a critical role in the evolution of the electric power industry by providing high-precision, real-time monitoring of essential power system metrics. However, effectively detecting abnormalities and critical events from PMU data is a complex task, complicated by intricate temporal patterns, a scarcity of labeled data for training algo- rithms, and constraints on online computational power. In this study, we apply TranAD, an innovative algorithm that combines transformer architectures with the refinement of adversarial learning, to both synthetic and real-world PMU datasets for developing a data quality and sensor online health monitoring platform for utilities. Our findings reveal that TranAD not only provides efficient detection and localization but also enhances the detail with which abnormalities are detected, marking a a significant step forward in the field of clean data acquisition processes for power system monitoring

deep neural network, machine learning (ML)↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors↗