Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Event Effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Update on Wide Bandgap (WBG) Device Radiation Hardness Assurance

This presentation provides an overview of recent wide bandgap device radiation hardness assurance activities at NASA and via NASA-funded grant vehicles. Devices include enhancement mode power GaN HEMTs, RF GaN HEMTs, and SiC MOSFETs and JBS diodes.

wide bandgap↗

Dealing with Ion LET Uncertainties: An Application of Generalized Linear Models

Although most SEE rate estimation methods presume a fit to SEE cross section vs. LET, fitting SEE data is challenging because the data are not compatible with the assumptions of many common fitting techniques (e.g. linear regression. The difficulty of fitting such data is compounded when the LET of the ion responsible for an SEE is uncertain. We modify a Generalized Linear Model SEE data fitting methodology to accommodate uncertain LET and apply the method to the problem of backside heavy-ion SEE testing to demonstrate the utility of the method, explore the dependence of systematic errors that arise from improper treatment of LET uncertainty and develop guidelines for minimizing such systematic errors when proper treatment is not possible. Additional applications are suggested and assessed for suitability of treatment by the model.

Single-event effects↗

Simulation-based Study of Single-Event Burnout in 4H-SiC High-Voltage Vertical Superjunction DMOSFET: Physical Failure Mechanism and Robustness vs. Performance Tradeoffs

We explore and elucidate physical failure mechanisms in a 4H-SiC, high voltage, superjunction (SJ) vertical DMOSFET from a single heavy ion strike using three-dimensional electro-thermal transient simulations. The single-event burnout (SEB) failure is thermal runaway from second breakdown, initiated by impact ionization and terminated with mesoplasma formation, at the center of the P-pillar/N+ substrate interface. We also demonstrate that the SEB performance of this SiC SJ DMOSFET is insensitive to the pillar width but sensitive to the strike location with ion strike at the P-pillar causing SEB at a lower blocking voltage than at the N-pillar. Compared to commercially available 1.2 kV blocking-rated non-SJ DMOSFETs, which have been demonstrated to survive SEB up to 525 V, the SJ DMOSFET increases SEB survival threshold voltage (VSEB) by a factor of 2.2, making it close to 1200 V, while the on-resistance is increased by only 11%. Using our recently developed figure of merit (FoM), which considers the trade-off between VSEB and on-state performance, we find that the SiC SJ DMOSFET achieves a FoM that is 14 times better, making it superior to conventional 1.2 kV SiC DMOSFETs for long-term radiation-tolerant operation in space applications.

Silicon Carbide↗

Space Radiation Environments Overview for MSFC Programs

Provide overview of Space Radiation Sources, Environments, Interactions with Electronic Devices - Radiation Sources - Solar Energetic Particles (SEP) and Solar Particle Events (SPE) - Galactic Cosmic Rays (GCR) - Radiation Environments - Van Allen belts - Beyond the belts - Reference SLS-SPEC-159 Rev G: Design Specification for Natural Environment (DSNE) - Interactions with Electronic Devices - Ionizing - Nonionizing - Internal Charging

Radiation Sources↗

NEPP Processor Enclave

Explore the source record for details and available documents.

graphics processing unit (GPU)↗

Under-Constrained SEE Data: Implications for Estimating and Bounding SEE Rates

Increasingly scarce SEE testing resources and rapid growth of the New Space sector have increased the prevalence of under-constrained SEE data. We develop Monte Carlo tools to assess implications for SEE rate estimation. We also show that Bayesian Priors based on large datasets of SEL susceptible parts can augment under-constrained data and improve bounds on SEL rates. The resulting Bayesian Priors are also useful for bounding system SEL risk.

Single-event effect↗

Schottky Diode Derating for Survivability in a Heavy Ion Environment

In this paper, we irradiate a number of silicon power Schottky diodes from a variety of manufacturers. The tested diodes represent a wide assortment of reverse voltages and forward currents. Additionally, we review correlations between single-event failures in Schottky diodes and device electrical parameters. The spatial locations of failures in the diode are discussed, as well as a possible explanation for why the failures occur. Based on these correlations to date, we propose a derating scheme for Schottky diodes flown in a heavy ion environment and suggest screening procedures for decreasing the risks of such failures.

Radiation effects↗

The effect of layout topology on single-event transient pulse quenching in a 65 nm bulk CMOS process.

Heavy-ion microbeam and broadbeam data are presented for a 65 nm bulk CMOS process showing the existence of pulse quenching at normal and angular incidence for designs where the pMOS transistors are in common n-wells or isolated in separate n-wells. Experimental data and simulations show that pulse quenching is more prevalent in the common n-well design than the separate n-well design, leading to significantly reduced SET pulsewidths and SET cross-section in the common n-well design.

99 GENERAL AND MISCELLANEOUS↗

Prediction of error rates in dose-imprinted memories on board CRRES by two different methods

An analysis of the expected space radiation effects on the single event upset (SEU) properties of CMOS/bulk memories onboard the Combined Release and Radiation Effects Satellite (CRRES) is presented. Dose-imprint data from ground test irradiations of identical devices are applied to the predictions of cosmic-ray-induced space upset rates in the memories onboard the spacecraft. The calculations take into account the effect of total dose on the SEU sensitivity of the devices as the dose accumulates in orbit. Estimates of error rates, which involved an arbitrary selection of a single pair of threshold linear energy transfer (LET) and asymptotic cross-section values, were compared to the results of an integration over the cross-section curves versus LET. The integration gave lower upset rates than the use of the selected values of the SEU parameters. Since the integration approach is more accurate and eliminates the need for an arbitrary definition of threshold LET and asymptotic cross section, it is recommended for all error rate predictions where experimental sigma-versus-LET curves are available.

Brucker, G. J.↗