Search NASASearch

SEARCH · Search NASA

Results for “sample design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Performance Improvement of LTS Undulators for Synchrotron Light Sources

The joint expertise of ANL and FNAL has led to the production of $\text{Nb}_{3}\text{Sn}$ undulator magnets in operation in the ANL Advanced Photon Source (APS). These magnets showed performance reproducibility close to the short sample limit, and a design field increase of 20% at 820 A. However, the long training did not allow obtaining the expected 50% increase of the on-axis magnetic field with respect to the ∼1 T produced at 450 A current in the ANL NbTi undulator. To address this, 10-pole long undulator prototypes were fabricated, and CTD-101K was replaced as impregnation material with TELENE, an organic olefin-based thermosetting dicyclopentadiene resin produced by RIMTEC Corporation, Japan. Training and magnet retraining after a thermal cycle were nearly eliminated, with only a couple of quenches needed before reaching short sample limit at over 1,100 A. TELENE will enable operation of $\text{Nb}_{3}\text{Sn}$ undulators much closer to their short sample limit, expanding the energy range and brightness intensity of light sources. TELENE is Co-60 gamma radiation resistant up to 7–8 MGy, and therefore already applicable to impregnate planar, helical and universal devices operating in lower radiation environments than high energy colliders.

43 PARTICLE ACCELERATORS

DESI 2024 II: sample definitions, characteristics, and two-point clustering statistics

We present the samples of galaxies and quasars used for DESI 2024 cosmological analyses, drawn from the DESI Data Release 1 (DR1). We describe the construction of largescale structure (LSS) catalogs from these samples, which include matched sets of synthetic reference ‘randoms’ and weights that account for variations in the observed density of the samples due to experimental design and varying instrument performance. We detail how we correct for variations in observational completeness, the input ‘target’ densities due to imaging systematics, and the ability to confidently measure redshifts from DESI spectra. We then summarize how remaining uncertainties in the corrections can be translated to systematic uncertainties for particular analyses. We describe the weights added to maximize the signalto-noise of DESI DR1 2-point clustering measurements. We detail measurement pipelines applied to the LSS catalogs that obtain 2-point clustering measurements in configuration and Fourier space. The resulting 2-point measurements depend on window functions and normalization constraints particular to each sample, and we present the corrections required to match models to the data. We compare the configuration- and Fourier-space 2-point clustering of the data samples to that recovered from simulations of DESI DR1 and find they are, generally, in statistical agreement to within 2% in the inferred real-space over-density field. The LSS catalogs, 2-point measurements, and their covariance matrices will be released publicly with DESI DR1.

79 ASTRONOMY AND ASTROPHYSICS

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development laboratories in Washington State. The U.S. Department of Energy (DOE) contracts to Battelle at Richland facilities on both the DOE Hanford Site and the Pacific Northwest National Laboratory (PNNL) Richland campus. These facilities have the potential for radionuclide air emissions. The PNNL contract with DOE also includes operations at the PNNL-Sequim campus in Sequim, where there is also the potential for radionuclide air emissions. This document is a periodic update that describes current PNNL facility emission units and sampling systems. The National Emission Standard for Hazardous Air Pollutants (NESHAP [40 Code of Federal Regulations 61, Subpart H]) requires an assessment of all emission units that have the potential for radionuclide air emissions. Emission units are registered with the State of Washington. Potential emissions from emission units are assessed annually by PNNL staff. Sampling, monitoring, and other regulatory compliance requirements are designated based on the potential to-emit dose criteria, a graded approach to facility-identified potential impact categories, and regulatory requirements. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled emission units, the building, exhaust unit, control technologies, and sample extraction details are provided. Additionally, applicable configuration drawings, figures, and photographs are included. For non-sampled emission units, emission estimation and radionuclide source details are provided. Site-wide permits for the lowest potential impact category are described. Deregistered/transitioned emission unit details are also provided as necessary for at least 5 years post-closure/transition. Currently, five emission units are sampled continuously for particulate radionuclides at PNNL managed facilities on the PNNL-Richland campus (3 of the 5) and on the Hanford Site (2 of the 5). Four of these units have sampling systems that comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1–2011 standard for sampling from stacks and ducts of nuclear facilities, and the fifth is grandfathered and compliant with the older ANSI N13.1–1969 standard. In addition, the PNNL-managed Hanford Site 325 Building EP 325-01-S stack is sampled continuously for emissions of tritium. No emissions sampling is required for the single licensed emission unit on the PNNL-Sequim campus.

54 ENVIRONMENTAL SCIENCES

Fine-tuning machine-learned particle-flow reconstruction for new detector geometries in future colliders

We demonstrate transfer learning capabilities in a machine-learned algorithm trained for particle-flow reconstruction in high energy particle colliders. This paper presents a cross-detector fine-tuning study, where we initially pretrain the model on a large full simulation dataset from one detector design, and subsequently fine-tune the model on a sample with a different collider and detector design. Specifically, we use the Compact Linear Collider detector (CLICdet) model for the initial training set and demonstrate successful knowledge transfer to the CLIC-like detector (CLD) proposed for the Future Circular Collider in electron-positron mode. We show that with an order of magnitude less samples from the second dataset, we can achieve the same performance as a costly training from scratch, across particle-level and event-level performance metrics, including jet and missing transverse momentum resolution. Furthermore, we find that the fine-tuned model achieves comparable performance to the traditional rule-based particle-flow approach on event-level metrics after training on 100,000 CLD events, whereas a model trained from scratch requires at least 1 million CLD events to achieve similar reconstruction performance. To our knowledge, this represents the first full-simulation cross-detector transfer learning study for particle-flow reconstruction. These findings offer valuable insights towards building large foundation models that can be fine-tuned across different detector designs and geometries, helping to accelerate the development cycle for new detectors and opening the door to rapid detector design and optimization using machine learning.

43 PARTICLE ACCELERATORS

Design of an 8-channel 40 GS/s 20 mW/Ch waveform sampling ASIC in 65 nm CMOS

One picosecond timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in TSMC 65 nm process targetting one picosecond resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing for picosecond time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC. PSEC5 has been submitted for fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Ramp-release experiments for strength measurements: Strain-rate dependence

This paper presents an enhanced analysis method for investigating material properties at high strain rates, extending the capability of established experimental techniques to gain more information. The ramp-release method has been applied to many experiments reported at high (≈10 5 − 10 6 s −1 ) strain-rates. More recent data gathered at the National Ignition Facility (NIF) has enabled higher (≈10 8 s −1 ) strain-rates to be studied. Here, we present an initial application of ramp-release analysis to NIF ramp-compression data, illustrating both the opportunities and the practical challenges of extending these methods to laser-driven platforms. The higher strain-rates accessed at the NIF mean that there is more strain-rate enhancement to strength, and the experimental configuration means that this enhancement is more readily seen in the data. This is enabled by the capability of avoiding peak-compression attenuation through the sample thickness with a designed hold period made possible by the pulse-shaping capability of NIF. We propose that this combination of experimental conditions and an enhanced analysis method enables the strain-rate enhancement to strength to be studied, and potentially for this to inform physics models at smaller scales than the continuum.

36 MATERIALS SCIENCE

Constant-Depth Preparation of Matrix Product States with Adaptive Quantum Circuits

Adaptive quantum circuits, which combine local unitary gates, midcircuit measurements, and feedforward operations, have recently emerged as a promising avenue for efficient state preparation, particularly on near-term quantum devices limited to shallow-depth circuits. Matrix product states (MPS) comprise a significant class of many-body entangled states, efficiently describing the ground states of one-dimensional gapped local Hamiltonians and finding applications in a number of recent quantum algorithms. Recently, it has been shown that the Affleck-Kennedy-Lieb-Tasaki state—a paradigmatic example of an MPS—can be exactly prepared with an adaptive quantum circuit of constant depth, an impossible feat with local unitary gates alone due to its nonzero correlation length [Smith , PRX Quantum 4, 020315 (2023)]. In this work, we broaden the scope of this approach and demonstrate that a diverse class of MPS can be exactly prepared using constant-depth adaptive quantum circuits, outperforming theoretically optimal preparation with unitary circuits. We show that this class includes short- and long-ranged entangled MPS, symmetry-protected topological (SPT) and symmetry-broken states, MPS with finite Abelian, non-Abelian, and continuous symmetries, resource states for MBQC, and families of states with tunable correlation length. Moreover, we illustrate the utility of our framework for designing constant-depth sampling protocols, such as for random MPS or for generating MPS in a particular SPT phase. We present sufficient conditions for particular MPS to be preparable in constant time, with global on-site symmetry playing a pivotal role. Altogether, this work demonstrates the immense promise of adaptive quantum circuits for efficiently preparing many-body entangled states and provides explicit algorithms that outperform known protocols to prepare an essential class of states. Published by the American Physical Society 2024

Smith, Kevin C. (ORCID:0000000223971518)

Wave-Optics Simulation Framework of Fourier Transform Holography with XMCD

We present a wave-optics simulation framework, implemented within the SRW, for modeling FTH with XMCD contrast. The framework propagates coherent, circularly polarized X-ray wavefronts from an undulator source through the sample and optics to the detector, reconstructing real-space images from the resulting holograms. Three principal extensions are introduced: (i) incorporation of polarization-dependent refractive indices in the sample plane, enabling direct simulation of XMCD contrast, (ii) a memory-efficient wavefront-splitting propagation scheme that treats individual apertures independently and coherently combines their fields at detector, and (iii) an integrated reconstruction module that delivers holographic images within the same framework. Together, these advances establish a versatile tool for quantitative exploration of coherence, aperture geometry, and detector sampling, and for the design and interpretation of XMCD-FTH experiments at synchrotron beamlines.

43 PARTICLE ACCELERATORS

A high-volume resonator for L-band DNP-NMR

DNP-NMR and EPR experiments that operate at or greater than L-band (i.e., ν 0 (e – ) = 1–2 GHz) are typically limited to maximum sample volumes of several hundred µL. These experiments rely on well-known resonator designs for DNP/EPR irradiation such as the loop-gap resonator and Alderman-Grant coil, where their maximum volumes limit further application to imaging experiments and high-throughput screening beyond L-band. Herein, we demonstrate a birdcage (BC) resonator design that can accommodate several mL of sample while operating around 1.5 GHz. The sample volume is maximized by using two identical BC resonators in a stacked configuration. Simulations are used to optimize the BC design and the performance is validated experimentally with liquid-state Overhauser-DNP-NMR experiments. This BC design exploits just the parasitic capacitance of conductive rings and features no fixed tuning capacitors. An enhancement of –77 is achieved on a 10 mM 4-Amino-TEMPO in H 2 O sample for a 5 mL sample volume. Finally, the associated sample heating is minimal due to the low-E-fields generated and the large sample mass with +3.4 K when driving 100 W for several seconds.

47 OTHER INSTRUMENTATION

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827

hiposa v0.1.0

Fast construction of hierarchical N-dimensional experimental design. The software allows construction of sampling strategies that are self-avoiding, tunable in resolution in N dimensions. This code is a drop-in replacement for seeding optimization runs often performed using uniform random sampling. The hierarchical approach allows for a rapid, top down method for construction the most effective design that drives towards a global optimum.

Zwart, PetrusH [Lawrence Berkeley National Laborat

Permeability and Induced Polarization of Mudstones

Electrical measurements can be used to estimate hydraulic properties such as permeability ( k ) in sedimentary rocks. Previous work has focused on sandstones, siltstones, and carbonates, while investigations on mudstones have rarely been reported. In this study, we report on electrical geophysical measurements for 23 mudstone samples using an experimental approach designed to reliably saturate these low permeability mudstones. The modified Hagen-Poiseuille model linking permeability to the formation factor ( F ) and an effective pore radius ( r ) provides an excellent fit to the data set with a near-constant pore radius, indicating that the effective porosity (1/ F ) is the controlling factor on k . In these samples, the surface area normalized to pore volume ( S por ), frequently used in permeability estimation models, varies by 1–2 orders of magnitude and is thus not a reliable proxy of the inverse effective hydraulic radius. The formation factor also exerts the primary control on induced polarization (IP) parameters, whereas Spor shows no relation to the IP parameters. A strong linear relationship is found between IP parameters (imaginary conductivity and normalized chargeability) and surface conductivity, although the proportionality factor is significantly lower than those observed in more permeable rocks and sediments. Apparent relationships between the polarization strength-derived and time constant-derived geophysical length scales and the effective hydraulic radius appear to be driven by variations in the electrochemical parameters (i.e., specific polarizability and diffusion coefficient). Overall, these findings emphasize that predicting hydraulic properties from electrical measurements in fine-grained rocks remains challenging and requires further investigation into the electrochemical properties involved.

58 GEOSCIENCES

Laboratory time series moisture manipulative experiment from sediment across the contiguous US: time series aerobic respiration and geochemistry (v2)

This dataset supports a broader study examining the effects of wetting and drying on hyporheic zone respiration across the contiguous United States (CONUS). The dataset provides data generated from a laboratory moisture manipulation experiment. The contents include time series aerobic respiration and moisture; dissolved oxygen; sediment geochemistry data; and field metadata (including qualitative information on instream and river corridor characteristics). Samples were collected as part of the WHONDRS CONUS-Scale Model-Sample Study (CM). This study was designed following ICON (integrated, coordinated, open, and networked) principles to facilitate a model-experiment (ModEx) iteration approach, leveraging crowdsourced sampling across the CONUS. The data package associated with the CM study is available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689. CM sampling began in April 2022 and ended in October 2023. This study uses subsamples from a subset of CM samples collected between June 2022 and June 2023. The original field samples were labeled as CM_###. Subsequent subsamples for this study were labeled as EC_###. The labels from the field samples and the EC subsamples can be mapped directly based on the digits following the prefix and underscore (i.e., EC_001 is a subsample from CM_001). See the critical details section below for more details on sample naming. This data package was originally published in August 2024. It was updated in February 2026 (v2; new and modified files). See the change history section in the readme for more details. For details on how to navigate this data package, see this infographic from the River Corridor SFA https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data and one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) readme; (5) field protocol; and a (6) a subfolder with sediment sample data from the incubation experiment. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC); (2) total nitrogen (TN); (3) adenosine triphosphate (ATP); (4) percent carbon and nitrogen; (5) effect size; (6) iron (II); (7) gravimetric moisture; (8) respiration rates and raw dissolved oxygen values; (9) specific conductance; (10) pH; (11) temperature; (12) a summary containing median values of each data type for each treatment (wet and dry); (13) methods codes; (14) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla FTICR-MS data. This folder contains three subfolders, one containing the sediment .xml data files, one containing the sediment CoreMS output files, the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .ref, or .xml.

54 ENVIRONMENTAL SCIENCES

HydraGNN_OPF_GFM_2026 - Ensemble of predictive graph foundation models for power grid applications

This dataset supports research on graph foundation models for optimal power flow (OPF) on electric grids using HydraGNN. It contains heterogeneous graph representations of PGLib-OPF cases spanning systems from 14 to 13,659 buses, together with packed HDF5 datasets for pretraining, feasibility classification, and N-1 contingency analysis. The release includes OPF solution data, downstream fine-tuning datasets, pretrained HeteroSAGE and HeteroHEAT model checkpoints, hyperparameter-optimization summaries across multiple heterogeneous GNN architectures, and aggregated fine-tuning results for sample-efficiency studies. The dataset is designed to enable scalable training, evaluation, and transfer-learning studies for OPF surrogate modeling, including node-level AC-OPF solution prediction, graph-level prediction, feasibility classification, operating-condition generalization, and contingency-response tasks.

24 POWER TRANSMISSION AND DISTRIBUTION

Measuring thermal curing induced shrinkage of material extrusion based additive manufacturing silicone elastomer lattices by X-ray computed tomography

Thermal curing induces shrinkage in material extrusion based additive manufacturing silicone elastomer samples, resulting in discrepancies between as printed and final geometries. Knowing the extent to which the samples change in shape and size allows us to make appropriate modifications to the printing design to better control the geometry of the samples. We present an X-ray computed tomography (CT) based approach to determine filament-level shrinkage due to thermal curing of silicone elastomer samples printed with direct ink writing (DIW). The approach relies on custom-designed build plates that are resistant to the elevated curing temperatures and that have sufficiently distinct X-ray absorption characteristics from the silicone elastomer to ensure adequate segmentation of the latter in X-ray imaging data. We implement the approach to evaluate shrinkage in DIW ‘log pile’ samples with three distinct strand arrangements and demonstrate of how filament-level information can be extracted from the X-ray CT data.

Additive manufacturing

Leveraging design of experiments to build chemometric models for the quantification of uranium (VI) and HNO3 by Raman spectroscopy

Partial least squares regression (PLSR) and support vector regression (SVR) models were optimized for the quantification of U(VI) (10–320 g L −1 ) and HNO 3 (0.6–6 M) by Raman spectroscopy with optimized calibration sets chosen by optimal design of experiments. The designed approach effectively minimized the number of samples in the calibration set for PLSR and SVR by selecting sample concentrations with a quadratic process model, despite complex confounding and covarying spectral features in the spectra. The top PLS2 model resulted in percent root mean square errors of prediction for U(VI), HNO 3 , and NO 3 − of 3.7%, 3.6%, and 2.9%, respectively. PLS1 models performed similarly despite modeling an analyte with a majority linear response (i.e., uranyl symmetric stretch) and another with more covarying vibrational modes (i.e., HNO 3 ). Partial least squares (PLS) model loadings and regression coefficients were evaluated to better understand the relationship between weaker Raman bands and covarying spectral features. Support vector machine models outperformed PLS1 models, resulting in percent root mean square error of prediction values for U(VI) and HNO 3 of 1.5% and 3.1%, respectively. The optimal nonlinear SVR model was trained using a similar number of samples (11) compared with the PLSR model, even though PLS is a linear modeling approach. The generic D-optimal design presented in this work provides a robust statistical framework for selecting training set samples in disparate two-factor systems. This approach reinforces Raman spectroscopy for the quantification of species relevant to the nuclear fuel cycle and provides a robust chemometric modeling approach to bolster online monitoring in challenging process environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

On the Sampling-Based Computation of Nash Equilibria Under Uncertainty via the Nikaido–Isoda Function

We consider the computation of an equilibrium of a stochastic Nash equilibrium problem, where the player objectives are assumed to be L 0 -Lipschitz continuous and convex, given rival decisions with convex and closed player-specific feasibility sets. To address this problem, we consider minimizing a suitably defined value function defined using the Nikaido–Isoda function. Such an avenue does not necessitate either monotonicity properties of the concatenated gradient map or potentiality requirements on the game but does require a suitable regularity requirement under which a stationary point is a Nash equilibrium. We design and analyze a sampling-enabled projected-gradient-response method, reliant on inexact resolution of a player-level best-response subproblem. Here, by deriving suitable Lipschitzian guarantees on the value function, we derive both asymptotic guarantees for the sequence of generated iterates as well as rate and complexity guarantees for computing a stationary point by appropriate choices of the sampling rate and inexactness sequence.

Nikaido-Isoda function