Search NASASearch

SEARCH · Search NASA

Results for “Vehicle-to-grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,786 records · Page 40

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

SWME

ELECTRIC PROPULSION- A NEW TECHNOLOGY

Within the past 3 years, electric thrust devices have passed from the first exploratory feasibility experiments to the flight-engineered hardware phase. This rapid surge of development has been punctuated by equally rapid improvements in the performance figures of electrical thrust devices. The most spectacular advances were made in ion engine technology. Total energy expenditure per ion pair has gone from 35,000 ev in 1958 to about 600 ev at the present time leading to power utilization efficiencies of up to 80 per cent, depending upon the specific impulse. The percentage of the particles intercepting the accelerating and focusing electrodes has been reduced from more than 50 per cent in 1958 to less than 0.01 per cent at the present time. Great improvements in ion current per unit area have also been realized, leading to greater thrust "pressures."

ELECTRIC PROPULSION

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277

Extreme confinement of hydrogen gas within fullerenelike nanoporous carbon

Nanoporous carbons and carbon nanostructures can store hydrogen at cryogenic temperatures but lack the volumetric and gravimetric capacity to be industrially significant. Recent inelastic neutron scattering experiments suggest a highly dense phase of hydrogen at temperatures well above the melting point of solid hydrogen. However, it remains unclear how pore geometry and intermolecular interactions enable these dense phases to exist, with dispersion (van der Waals) or electrostatic/induction suggested to be the key effects in slit and curved pores but their relative contributions have yet to be quantified. In this paper, we perform benchmark electronic structure calculations allowing the interactions between planar and curved aromatic molecules with hydrogen to be accurately determined. Dispersion was found to dominate over electrostatic and inductive effects with some many-body charge transfer (Dobson type-A) effects needed to capture the most highly curved structures. Density functional methods that include type-A many-body effects were found to accurately describe the intermolecular interactions at a fraction of the cost of coupled-cluster simulations and these approaches were used to calculate the energies inside large carbon bowl and slit pores. The interaction energies inside the bowl pores were found to depend on the orientation of the hydrogen molecule. This rotational barrier, modeled as a quantum hindered rotor, could reproduce the peak splitting observed in inelastic neutron scattering experiments, with weak splitting arising from bowl-like fullerene pores and strong splitting from highly confining nanotubelike pores. Increasing the fraction of such curved pores in nanoporous carbons may therefore offer a pathway to enhance their hydrogen-storage capacity. Moreover, the preferential adsorption of ortho hydrogen on nanotubelike pores could enable the storage of high-density hydrogen without the need to remove heat produced during the ortho-para hydrogen conversion.

36 MATERIALS SCIENCE

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed

Resolving root causes of experiment discrepancies guided by machine learning

Abstract Scientists rely on accurate experimental data to explain nature and then harness this knowledge for applications addressing human needs. However, discrepancies between experiments of the same observable can impede scientific progress if one does not understand the underlying causes. Here, we developed a process that unravels data discrepancies by first using Bayesian machine learning to relate discrepancies to few of many, potentially biasing metadata features that encode experiment procedures. This machine learning output guides human experts to study discrepancy causes by simulating suspicious aspects of historical experiments or designing modern ones to address open questions. The study findings then lead to rejecting or correcting historical data on firm scientific bases. This process is demonstrated for the energy spectrum of neutrons emitted promptly (<1 ns) after fission of 252 Cf, a trusted nuclear physics Standard. It reduces the spread in experimental 252 Cf spectra by up to a factor of 6.

Neudecker, D. (ORCID:0000000339200627)

SAVY-4000 Finite-Element Drop Test Analysis

PFE Auxiliary Systems conducted drop testing on SAVY-4000 containers to evaluate structural response under 12-foot drop conditions. In support of that effort, a finite-element modeling capability was developed to simulate drop response across multiple container sizes and impact orientations. The purpose of this work was to provide a consistent analysis framework that could support interpretation of testing, compare response trends across multiple configurations, and generate quantities of interest for later comparison with experimental data. More broadly, the analysis and testing were intended to assess whether the containers continued to perform their primary function after a 12-foot drop, namely maintaining structural integrity and containment of the contents. The modeling approach combined an implicit preload analysis with an explicit drop simulation so that each drop event began from a mechanically realistic assembled condition, including compression of the silicone O-ring. Separate models were developed for 2-quart, 5-quart, 12-quart, and 10-gallon containers. The results were evaluated in terms of strain-gauge response, collar-lid gap behavior, and accumulated plastic strain. In addition, parametric studies were performed on the 2-quart container to assess sensitivity to O-ring stiffness, friction, canister thickness, geometry tolerance, and mesh density. The simulations showed that predicted drop responses depended strongly on both container size and drop orientation. Gap metrics identified cases in which the predicted collar-lid opening exceeded the nominal O-ring cross-section threshold, while plastic strain metrics identified localized regions of elevated permanent deformation. Parametric studies showed that the predicted response was especially sensitive to the assumed O-ring stiffness and contact friction, while the geometry tolerance study produced smaller changes in the cases examined. The main value of this work was that it established a repeatable modeling and simulation workflow to support drop-test implementation, evaluate effects of future configuration changes, and understand modeling assumptions that most influenced predicted response. At the current stage, the results were viewed as preliminary model predictions rather than validated predictions. The next step would be to compare drop-test data to the model so that predictive values of the workflow could be refined and used with greater confidence to assess whether the containers maintained structural integrity and containment of the contents after a 12-foot drop.

42 ENGINEERING

Dimensional Reduction for Sampled Priors and Application to Photometric Redshift Distributions

A typical Bayesian inference on the values of some parameters of interest q from some data D involves running a Markov Chain (MC) to sample from the posterior $p$($q$,$n$|$D$) $\propto$ $\mathcal{L}$($D$|$q$,$n$)$p$(q)$p$($n$), where n are some nuisance parameters with a separable prior. In some cases, the nuisance parameters are high-dimensional, and their prior p(n) is itself defined only by a set of samples that have been drawn from some other MC. The MC for the posterior will typically require evaluation of p(n) at arbitrary values of n, i.e., one needs to provide a density estimator over the full n space from the provided samples. But the high dimensionality of n hinders both the density estimation and the efficiency of the MC for the posterior. We describe a solution to this problem: a linear compression of the n space into a much lower-dimensional space u, which projects away directions in n space that cannot appreciably alter $\mathcal{L}$. The algorithm for doing so is a slight modification to principal components analysis, and is less restrictive on p(n) than other proposed solutions to this issue. We demonstrate this “mode projection” technique using the analysis of 2-point correlation functions of weak lensing fields and galaxy density in the Dark Energy Survey, where n is a binned representation of the redshift distribution n(z) of the galaxies.

79 ASTRONOMY AND ASTROPHYSICS

Assessing the Adhesion of Nanofibrous PVDF-HFP as Passive Thermal Control Coatings for the Extraterrestrial Storage of Cryogenic Propellants

Cryogenic propellant passive thermal management techniques in space are essential complements to active thermal management methods, helping reduce absolute dependence on the latter. Particularly, materials with superior optical properties (high solar reflectance and infrared emittance) would be beneficial for passive thermal control to reject most of the incident solar radiation and enhance thermal emission from the storage tank, leading to self-cooling. We developed a nanofibrous, porous passive thermal control material by electrospinning polyvinylidene fluoride-co-hexafluoropropylene (PVDF-HFP) co-polymer onto an aluminum foil substrate. The material exhibits a very high solar reflectance (>99%) and infrared emittance (~86%) when characterized in the ultraviolet-visible-near infrared and mid-infrared wavelengths. This study focuses on the adhesion of the nanofibrous PVDF-HFP to the substrate. We incorporated in-lab fabricated and commercial adhesives, under normal room conditions, between the nanofibers and the aluminum foil substrate to improve their adhesion. Some samples were also exposed to space-like conditions – vacuum and thermal cycling, to investigate their effects on the strengths of adhesives. Subsequently, adhesion peel tests were conducted on all the samples to assess the peel strengths of the bonds. Peel test strengths after space environment conditioning of the adhesives were generally higher than those observed in the pristine, unaged samples. The results are discussed in this study.

Chieloka Ibekwe

Fuel injector design for high temperature aircraft engine

The objective of the Innovative High Temperature Aircraft Engine Fuel Nozzle Program was to design and evaluate a nozzle capable of operating at a combustor inlet air temperature of 1600 F (1144 K) and a fuel temperature of 350 F (450 K). The nozzle was designed to meet the same performance requirements and fit within the size envelope of a current production dual orifice fuel nozzle. The design approach was to use improved thermal protection and fuel passage geometry in combination with fuel passage surface treatment to minimize coking at these extreme fuel and air temperatures. Heat transfer models of several fuel injector concepts were used to optimize the thermal protection, while sample tube coking tests were run to evaluate the effect of surface finish, coatings and tube material on the coking rate. Based on heat transfer analysis, additional air gaps, reduced fuel passage flow area and use of ceramic tip components reduced local fuel wetted wall temperatures by more than 200 F (100 K) when compared to a current production fuel nozzle. Sample tube coking test results showed the importance of surface finish on the fuel coking rate. Therefore, a one micro-inch (0.025 micron) roughness was specified for all fuel passage surfaces. A novel flow divider valve in the tip was also employed to reduce weight, allow room for additional thermal protection, and provide back pressure to reduce the risk of fuel vaporization. The fuel nozzle was fabricated and evaluated in a series of high temperature coking tests. Initial results of these tests indicate that thermal protection and surface treatments were partially successful in preventing nozzle fouling, but additional refinement of the internal flowpath is needed to prevent buildup of coke particles that partially blocked the spin slots which meter the nozzle fuel flow.

R. W. Stickles

Evaluation of Low-Energy Hydrogen Separation Method Using Metal-Organic Frameworks (MOFs) for Closed-Loop ECLSS Air Revitalization (CLEAR)

The State-of-the-Art (SOA) air revitalization architecture onboard the International Space Station (ISS) recovered approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ) via the Sabatier process from 2011 to 2017. O 2 recovery is currently constrained by the limited availability of reactant hydrogen (H 2 ) preventing complete conversion of CO 2 to H 2 O. Increasing O 2 recovery within Closed-Loop ECLSS is essential to reducing resupply mass for long-duration manned missions; specifically focusing on water (H 2 O) which supplies H 2 for Sabatier via water electrolysis. Past ground test endeavors at Marshall Space Flight Center (MSFC) have attempted to recover H 2 from Sabatier-produced CH 4 using technologies such as carbon vapor deposition (CVD) and plasma pyrolysis. The byproducts of these technologies can act as a catalyst poison or reactor deadload to the Sabatier reactor. Hydrogen separation techniques must be utilized to maintain the Sabatier catalyst during gas recycling and must be scalable, non-energy intensive, and safe to operate in a habitation setting. Research indicated that metal-organic frameworks (MOFs) could meet these criteria and were tested for their capability to capture the various carbon-based gaseous products of CVD and plasma pyrolysis such as acetylene (C 2 H 2 ), ethylene (C 2 H 4 ), ethane (C 2 H 6 ), and carbon monoxide (CO) which would purify the hydrogen gas stream passing through the MOF. A sub-scale adsorption column was developed by Marshall Space Flight Center to test three MOF candidates against a synthetic gas mixture comprised of process-relevant carbonous gases and hydrogen to evaluate the separation capability of the MOFs. The results of the hydrogen separation capability, isothermal desorption capability, and demonstrated cyclic reuse of the MOF are presented in this paper.

Kagen Crawford

Space Environments and their Effects on Space Automation and Robotics

Automated and robotic systems will be exposed to a variety of environmental anomalies as a result of adverse interactions with the space environment. As an example, the coupling of electrical transients into control systems, due to EMI from plasma interactions and solar array arcing, may cause spurious commands that could be difficult to detect and correct in time to prevent damage during critical operations. Spacecraft glow and space debris could introduce false imaging information into optical sensor systems. The presentation provides a brief overview of the primary environments (plasma, neutral atmosphere, magnetic and electric fields, and solid particulates) that cause such adverse interactions. The descriptions, while brief, are intended to provide a basis for the other papers presented at this conference which detail the key interactions with automated and robotic systems. Given the growing complexity and sensitivity of automated and robotic space systems, an understanding of adverse space environments will be crucial to mitigating their effects.

Henry B Garrett

Battery Cell Balancing System and Method

A battery cell balancing system is operable to utilize a relatively small number of transformers interconnected with a battery having a plurality of battery cells to selectively charge the battery cells. Windings of the transformers are simultaneously driven with a plurality of waveforms whereupon selected battery cells or groups of cells are selected and charged. A transformer drive circuit is operable to selectively vary the waveforms to thereby vary a weighted voltage associated with each of the battery cells.

Davies, Francis J.

Ultrasonic Washer–Dryer System for Space Habitats: Design Upgrades and Parabolic Flight Readiness

Clothing makes up nearly 25% of all non-food supplies sent to the International Space Station (ISS). To support sustainable human missions in deep space, NASA’s Life Support and Habitation Systems Focus Area looks to advance technologies to support and improve logistics. Our team is creating a compact ultrasonic clothing washer/dryer system that bypasses traditional limitations and is suitable for space. Thermal drying uses a lot of energy to evaporate water, while our ultrasonic drying method offers a quicker, more efficient alternative. It uses piezoelectric transducers to vibrate textiles at the micron scale, mechanically removing water as cold mist rather than evaporating it. This speeds up drying and reduces energy use, no matter the fabric makeup. This paper details recent upgrades to a full-scale ultrasonic washer–dryer system, readying it for parabolic flight testing. Improvements include an enhanced human–machine interface, better packaging, and optimized performance and control. We also present extensive pre-flight ground tests conducted to ensure reliability and identify potential risks. Collaborating with P&G, we report preliminary cleaning tests using various detergents. These results lay a crucial foundation for the laundry system designed specifically for space. By cutting clothing-related payload and waste by over 97%, this technology supports long-term human exploration missions on the ISS, the Moon, Mars, and beyond.

Laundry

Adaptive Curation at NASA Johnson Space Center: Preparing for Artemis Samples by Leveraging Proven Practices and Innovative Solution

The proper curation of returned astromaterial samples is essential to ensure that high-quality scientific investigations can be conducted for decades, enabling future generations to address evolving research questions. The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is responsible for curating all of NASA’s extraterrestrial samples. Under the governing document, NASA Procedural Requirement (NPR) 7100.5 “Curation of Extraterrestrial Materials”, JSC Curation is charged with “The curation of all extraterrestrial material under NASA control, including future NASA missions.” The Directive goes on to define Curation as including “...documentation, preservation, preparation, and distribution of samples for research, education, and public outreach.” JSC Curation has a long-standing legacy of curating extraterrestrial materials, including but not limited to Apollo and Luna lunar samples, Genesis solar wind samples, Stardust comet samples, asteroid samples (Hayabusa1, Hayabusa2, and OSIRIS-REx), and Antarctic Meteorite samples from a variety of parent bodies. Building on this foundation, the Artemis program introduces new challenges and opportunities for sample curation, requiring both the application of proven practices and the development of innovative solutions. The Artemis Collection will be curated using established protocols refined through decades of experience with Apollo and subsequent sample collections, including but not limited to the utilization of cleanrooms, custom nitrogen gloveboxes, specialized storage containers and tools; all of which have strict material utilization and prohibition requirements. These practices provide a robust framework for contamination control, documentation, and long-term preservation. However, Artemis samples may present unique scientific and operational requirements, including enhanced contamination control measures (relative to Apollo) driven by evolving science objectives. To meet these needs, JSC Curation is actively developing new technologies and protocols that extend beyond traditional approaches, ensuring that the integrity of samples is maintained under increasingly stringent standards. One critical area of innovation is the development of cold sample curation capabilities. Certain Artemis samples, particularly those from Permanently Shadowed Regions (PSRs) and cold environments, are expected to contain ices and volatile components that require preservation and handling at sub-zero or even cryogenic temperatures. JSC Curation is leveraging best practices from the cold and cryogenic sample industries, as well as other government agencies and academic experts, to design facilities and handling procedures that maintain sample integrity while enabling scientific access. The goal is to develop capabilities to allow researchers to investigate volatiles and other temperature-sensitive materials while minimizing chemical and physical alterations from their returned state. In summary, adaptive curation at JSC combines the reliability of proven methodologies with forward-looking innovations to meet the scientific and operational demands of Artemis. Through enhanced contamination control, advanced cold curation capabilities, and an understanding of known and evolving future science priorities, NASA is preparing to maximize the scientific return from Artemis samples and preserve their value for generations of researchers.

Andrea D Harrington

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]