Search NASASearch

SEARCH · Search NASA

Results for “Single Event Effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Proton Single Event Effects (SEE) Testing of the Myrinet Crossbar Switch and Network Interface Card

As part of the Remote Exploration and Experimentation Project (REE), work was performed to do a proton SEE (Single Event Effect) evaluation of the Myricom network protocol system (Myrinet). This testing included the evaluation of the Myrinet crossbar switch and the Network Interface Card (NIC). To this end, two crossbar switch devices and five components in the NIC were exposed to the proton beam at the University of California at Davis Crocker Nuclear Laboratory (CNL).

Howard, James W., Jr.

Single-Event Effect Testing of the ON Semiconductor BSS123 N-Channel Logic Level Enhancement Mode FET and the Vishay Si1013R P-Channel MOSFET

This study was undertaken to determine the single event effect (SEE) susceptibility of two different MOSFET components. Heavy-ion testing was conducted at the Lawrence Berkeley National Laboratory (LBNL) Berkeley Accelerator Space Effects (BASE) Facility 88” Cyclotron. Its purpose was to evaluate these devices as candidates for use on Goddard Modular SmallSat Architecture (GMSA) adapter board for the GTOSat project.

Michael J Campola

Single-Event Effect Report for EPC Series eGaN FETs: The Effect of Load Conditions on Destructive SEE

Recent testing of Enhanced Power Conversion (EPC) eGaN FET devices design for power use has shown that the devices are susceptible to Single-Event Effects (SEE) that degrade or destroy the device. The exact mechanism of the SEE is not known. The testing so far has been in the static condition, in the fully off condition, and with minimal load conditions. These conditions may not be worst case. This report presents the results of a study that tests some of the load conditions for SEE. The EPC2012 and EPC1012 were chosen for the test. The tests were performed the TAMU radiation effects facility in May and June of 2013.

Scheick, Leif

The Use of High Energy Heavy Ion Facilities for Single Event Effects (SEE) Testing: A Perspective on Return on Investment (ROI)

With challenges related to testing highly complex integrated circuits as well as entire systems continuing to grow, the use of higher energy heavy ions for single-event effects (SEE) testing becomes a critical technical need. This presentation, however, focuses only partially on the technical side with the main emphasis on the economics of using a high-energy heavy ion beam and comparing via notional cost models for testing.

Kenneth A. LaBel

Single-Event Effect Report for EPC Series eGaN FETs: EPC2015, EPC2014, EPC2012

Heavy ion testing of newly available eGaN FETs from EPC were tested in May of 2012 at TAM. The EPC2001, EPC2012, and EPC2014 were tested for general single-event effect response from gold and xenon ions. Overall, the devices showed radiation degradation commensurate with breakdown in isolation oxides, and similar testing by EPC and Microsemi agrees with these data.

Scheick, Leif

Xilinx Kintex-UltraScale Field Programmable Gate Array Single Event Effects (SEE) Heavy-Ion Test Report

This is an independent investigation that evaluates the single event destructive and transient susceptibility of the Xilinx Kintex-UltraScale device. Design/Device susceptibility is determined by monitoring the device under test (DUT) for Single Event Transient (SET) and Single Event Upset (SEU) induced faults by exposing the DUT to a heavy ion beam. Potential Single Event Latch-up (SEL) is monitored throughout heavy-ion testing by examining device current. This device does not have embedded mitigation. Hence, user implemented mitigation is investigated using Synopsys mitigation tools.

Single Event Transient (SET)

Radiation Single Event Effects (SEE) Impact on Complex Avionics Architecture Reliability

The NASA Engineering and Safety Center (NESC) has an urgent need to understand how system-level reliability of an avionics architecture is compromised when portions of the architecture are temporarily unavailable due to single event effects (SEE). The proposed activity parametrically evaluated these SEE impacts on system reliability based on mission duration, upset rate and recovery times for a representative redundant architecture. The key stakeholders for this study are NASA programs and projects that expect to use avionics architectures with electrical, electronic and electromechanical (EEE) parts susceptible to SEE when exposed to the mission expected radiation environment.

Hodson, Robert F.

Investigation of HZETRN 2010 as a Tool for Single Event Effect Qualification of Avionics Systems

NASA's future missions are focused on deep space for human exploration that do not provide a simple emergency return to Earth. In addition, the deep space environment contains a constant background Galactic Cosmic Ray (GCR) radiation exposure, as well as periodic Solar Particle Events (SPEs) that can produce intense amounts of radiation in a short amount of time. Given these conditions, it is important that the avionics systems for deep space human missions are not susceptible to Single Event Effects (SEE) that can occur from radiation interactions with electronic components. The typical process to minimizing SEE effects is through using heritage hardware and extensive testing programs that are very costly. Previous work by Koontz, et al. [1] utilized an analysis-based method for investigating electronic component susceptibility. In their paper, FLUKA, a Monte Carlo transport code, was used to calculate SEE and single event upset (SEU) rates. This code was then validated against in-flight data. In addition, CREME-96, a deterministic code, was also compared with FLUKA and in-flight data. However, FLUKA has a long run-time (on the order of days), and CREME-96 has not been updated in several years. This paper will investigate the use of HZETRN 2010, a deterministic transport code developed at NASA Langley Research Center, as another tool that can be used to analyze SEE and SEU rates. The benefits to using HZETRN over FLUKA and CREME-96 are that it has a very fast run time (on the order of minutes) and has been shown to be of similar accuracy as other deterministic and Monte Carlo codes when considering dose [2, 3, 4]. The 2010 version of HZETRN has updated its treatment of secondary neutrons and thus has improved its accuracy over previous versions. In this paper, the Linear Energy Transfer (LET) spectra are of interest rather than the total ionizing dose. Therefore, the LET spectra output from HZETRN 2010 will be compared with the FLUKA and in-flight data to validate HZETRN 2010 as a computational tool for SEE qualification by analysis. Furthermore, extrapolation of these data to interplanetary environments at 1 AU will be investigated to determine whether HZETRN 2010 can be used successfully and confidently for deep space mission analyses.

Rojdev, Kristina

Investigation of HZETRN 2010 as a Tool for Single Event Effect Qualification of Avionics Systems

NASA's future missions are focused on long-duration deep space missions for human exploration which offers no options for a quick emergency return to Earth. The combination of long mission duration with no quick emergency return option leads to unprecedented spacecraft system safety and reliability requirements. It is important that spacecraft avionics systems for human deep space missions are not susceptible to Single Event Effect (SEE) failures caused by space radiation (primarily the continuous galactic cosmic ray background and the occasional solar particle event) interactions with electronic components and systems. SEE effects are typically managed during the design, development, and test (DD&T) phase of spacecraft development by using heritage hardware (if possible) and through extensive component level testing, followed by system level failure analysis tasks that are both time consuming and costly. The ultimate product of the SEE DD&T program is a prediction of spacecraft avionics reliability in the flight environment produced using various nuclear reaction and transport codes in combination with the component and subsystem level radiation test data. Previous work by Koontz, et al.1 utilized FLUKA, a Monte Carlo nuclear reaction and transport code, to calculate SEE and single event upset (SEU) rates. This code was then validated against in-flight data for a variety of spacecraft and space flight environments. However, FLUKA has a long run-time (on the order of days). CREME962, an easy to use deterministic code offering short run times, was also compared with FLUKA predictions and in-flight data. CREME96, though fast and easy to use, has not been updated in several years and underestimates secondary particle shower effects in spacecraft structural shielding mass. Thus, this paper will investigate the use of HZETRN 20103, a fast and easy to use deterministic transport code, similar to CREME96, that was developed at NASA Langley Research Center primarily for flight crew ionizing radiation dose assessments. HZETRN 2010 includes updates to address secondary particle shower effects more accurately, and might be used as another tool to verify spacecraft avionics system reliability in space flight SEE environments.

Rojdev, Kristina

Single Event Effect (SEE) Test Planning 101

This is a course on SEE Test Plan development. It is an introductory discussion of the items that go into planning an SEE test that should complement the SEE test methodology used. Material will only cover heavy ion SEE testing and not proton, LASER, or other though many of the discussed items may be applicable. While standards and guidelines for how-to perform single event effects (SEE) testing have existed almost since the first cyclotron testing, guidance on the development of SEE test plans has not been as easy to find. In this section of the short course, we attempt to rectify this lack. We consider the approach outlined here as a "living" document: mission specific constraints and new technology related issues always need to be taken into account. We note that we will use the term "test planning" in the context of those items being included in a test plan.

LaBel, Kenneth A.

Single Event Effects Testing of the Linfinity SG1525A Pulse Width Modulator Controller

Pulse Width Modulator (PWM) Controllers are the heart of switching power supply systems in development today. The PWMs considered here have the same integration advantages as many other controllers but it also includes the interface drivers for the follow-on power Field Effect Transistors (FET). Previous work on these types of devices looked into the required test methodologies [ 11 and the impact of radiation on the soft start and shutdown circuits of typically incorporated in the technology [2]. Taking advantage of this previous work this study was undertaken to determine the single event destructive and transient susceptibility of the Linfinity SG1525A Pulse Width Modulator Controller. The device was monitored for transient interruptions in the output signals and for destructive events induced by exposing it to a heavy ion beam at the Texas A&M University Cyclotron Single Event Effects Test Facility. After exposing these devices to the beam, a new upset mode has been identified that can lead to catastrophic power supply system failure if this event would occur while drive power FETs off the two device outputs. The devices and the test methods used will be described first. This will be followed by a brief description of the data collected to date (not all data can be presented with the length constraints of the summary) and a summary of the key results.

Howard, J. W., Jr.

Microsemi RTG4 Rev C Field Programmable Gate Array Single Event Effects (SEE) Heavy-Ion Test Report

The goal of this study was to perform an independent investigation of single event destructive and transient susceptibility of the Microsemi RTG4 device. The devices under test were the Microsemi RTG4 field programmable gate array (FPGA) Rev C. The devices under test will be referenced as the DUT or RTG4 Rev C throughout this document. The DUT was configured to have various test structures that are geared to measure specific potential susceptibilities of the device. DesignDevice susceptibility was determined by monitoring the DUT for Single Event Transient (SET) and Single Event Upset (SEU) induced faults by exposing the DUT to a heavy ion beam. Potential Single Event Latch-up (SEL) was checked throughout heavy-ion testing by monitoring device current.

Field Programmable Gate Array (FPGA)

Analysis and Simulations of Space Radiation Induced Single Event Effects and Transients

Spacecraft electronic are affected by the space radiation environment. Among the different types of radiation effects that can affect spacecraft electronics is the single event transient (SET). The space environment is responsible for many of the single event transients which can upset the performance of the spacecraft avionics hardware. In this chapter we first explore the origins of single event transients, then explore the modeling of a single event transient in digital and analog circuit. The chapter also addresses the concept of crosstalk that could develop among digital circuits in the present of a SET event. The chapter also provides a discussion of SET hardening. We then provide a discussion concerning propagation of a single event transient event at the local, subsystem, and system level in a spacecraft using two different models, one of the models developed by the author, known as the state transition model. The final goal of the chapter is to provide a qualitatively methodology for assessing single event transients and its effects so that spacecraft avionics engineers can develop either hardware or software countermeasures in their designs. SET is not a form of electromagnetic interference (EMI) in its origin, but semantically SET is very similar to EMI because they are both caused a current source not previously accounted for. SET has the same effects as EMI and it can cause interference problems in electronic circuits via multiple coupling mechanisms similar to EMI, and therefore makes such circuits incompatible.

Perez, Reinaldo J.

Single Event Effects in Highly Scaled Devices for Space Applications

This paper discusses single-event upset (SEU) in memories and microprocessors that are the "drivers" of highly scaled commercial integrated circuits. Despite the decrease in critical charge that occurs for highly scaled CMOS devices, recent test data has shown that SEU rates are actually somewhat lower for scaled devices compared to older devices with larger feature size. Hard errors, which are increasingly important for memories, are discussed along with conventional soft errors. Functional errors in memories and microprocessors are particularly significant, and tend to dominate the response of highly scaled devices from an application standpoint. Predictions for future devices are made using the Semiconductor Industry Roadmap along with recent modeling and radiation test results.

microelectronics