Search NASA⌕ Search

SEARCH · Search NASA

Results for “DYNAMITRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

"DIANA" - A New, Deep-Underground Accelerator Facility for Astrophysics Experiments

The DIANA project (Dakota Ion Accelerators for Nuclear Astrophysics) is a collaboration between the University of Notre Dame, University of North Carolina, Western Michigan University, and Lawrence Berkeley National Laboratory to build a nuclear astrophysics accelerator facility 1.4 km below ground. DIANA is part of the US proposal DUSEL (Deep Underground Science and Engineering Laboratory) to establish a cross-disciplinary underground laboratory in the former gold mine of Homestake in South Dakota, USA. DIANA would consist of two high-current accelerators, a 30 to 400 kV variable, high-voltage platform, and a second, dynamitron accelerator with a voltage range of 350 kV to 3 MV. As a unique feature, both accelerators are planned to be equipped with either high-current microwave ion sources or multi-charged ECR ion sources producing ions from protons to oxygen. Electrostatic quadrupole transport elements will be incorporated in the dynamitron high voltage column. Compared to current astrophysics facilities, DIANA could increase the available beam densities on target by magnitudes: up to 100 mA on the low energy accelerator and several mA on the high energy accelerator. An integral part of the DIANA project is the development of a high-density super-sonic gas-jet target which can handle these anticipated beam powers. The paper will explain the main components of the DIANA accelerators and their beam transport lines and will discuss related technical challenges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A New High-Current Proton Accelerator

A high-current (>20 mA) dc proton accelerator is being developed for applications such as boron neutron capture therapy (BNCT) and the detection of explosive materials by nuclear resonance absorption (NRA) of gamma radiation. The high-voltage dc accelerator (adjustable between 1.4 and 2.8 MeV) will be a single-ended industrial Dynamitron registered system equipped with a compact high-current, microwave-driven proton source. A magnetic mass analyzer inserted between the ion source and the acceleration tube will select the protons and reject heavier ions. A sorption pump near the ion source will minimize the flow of neutral hydrogen gas into the acceleration tube. For BNCT, a lithium target for generating epithermal neutrons is being developed that will be capable of dissipating the high power (>40 kW) of the proton beam. For NRA, special targets will be used to generate gamma rays with suitable energies for exciting nuclides typically present in explosive materials. Proton accelerators with such high-current and high-power capabilities in this energy range have not been developed previously.

43 PARTICLE ACCELERATORS↗

Monte Carlo Simulation of the Irradiation of Alanine Coated Film Dosimeters with Accelerated Electrons

The Monte Carlo code PENELOPE was used to simulate the irradiation of alanine coated film dosimeters with electron beams of energies from 1 to 5 MeV being produced by a high-current industrial electron accelerator. This code includes a geometry package that defines complex quadratic geometries, such as those of the irradiation of products in an irradiation processing facility. In the present case the energy deposited on a water film at the surface of a wood parallelepiped was calculated using the program PENMAIN, which is a generic main program included in the PENELOPE distribution package. The results from the simulation were then compared with measurements performed by irradiating alanine film dosimeters with electrons using a 150 kW Dynamitron electron accelerator. The alanine films were placed on top of a set of wooden planks using the same geometrical arrangement as the one used for the simulation. The way the results from the simulation can be correlated with the actual measurements, taking into account the irradiation parameters, is described. An estimation of the percentage difference between measurements and calculations is also presented.

61 RADIATION PROTECTION AND DOSIMETRY↗

Physics

Polar substorm model on auroral effects, algebra of fermi-dirac operators applied to many-body problems, and dynamitron accelerator as thermal neutron source

MANY-BODY PROBLEM↗

Optical absorption in fused silica at elevated temperatures during 1.5-MeV electron irradiation

An experimental determination of the optical transmission of Corning 7940 UV and Suprasil 1 and 2 fused silica has been made during 1.5-MeV electron bombardment. The fused silica reached temperatures ranging from 150 to 1000 C. The Lewis Research Center dynamitron provided electron current densities which corresponded to a dose rate of 2.6 to 20 Mrad/sec. The irradiation induced absorption was measured at 215.0, 270.0, and 450.0 nm (2150, 2700, 4500 A). The length of each irradiation was sufficient so that an equilibrium between radiation induced coloration and high temperature annealing was reached. The experimental results indicate a significant optical absorption, with values of the induced absorption coefficient at 215.0 nm (2150 A) of 14.5 to 2.2/cm, at 270.0 nm (2700 A) of 9.7 to 3.0/cm and at 450.0 nm (4500 A) of 3.7 to 0.5/cm. This would make the use of fused silica as the separating wall material in the nuclear light bulb propulsion concept questionable.

Smith, A. B.↗

Optical transmittance of fused silica at elevated temperatures during high energy electron bombardment.

An experimental determination of the optical transmission of Corning 7940 UV and Suprasil I fused silica has been made. The LeRC dynamitron provided the equivalent ionizing radiation and high temperature that the transparent gas divider of an operating nuclear light bulb engine would experience. The irradiation induced absorption was measured at 2150 A, 2700 A, and 4500 A. The length of the irradiations were sufficient so that an equilibrium between radiation induced coloration and high temperature annealing was reached. The experimental results indicate a significant optical absorption, particularly at the shorter wavelength, which would make the use of fused silica in this concept questionable.

Smith, A. B.↗

Measurements of the UV and VUV transmission of optical materials during high energy electron irradiation

An experimental program was conducted in which the optical transmission of several transparent materials was measured during high energy electron irradiation. These experiments were conducted using the Dynamitron electron accelerator as a continuous source of 1.5 MeV electrons and the LINAC electron accelerator as a pulsed source of 5-7 MeV electrons. The experimental program consisted of three major portions. The first portion, the optical transmission of fused silica, BeO, MgF2, and LiF was measured at vacuum ultraviolet wavelengths in the range 1550-2000 A during ambient temperature, 1.5 MeV electron irradiation at ionizing dose rates to 0.5 Mrad/sec. In the second portion of the program, the optical transmission of fused silica and BeO was measured in the range 2000-3000 A during high dose rate, elevated temperature 1.5 MeV electron irradiation. In particular, accurate measurements of the optical transmission were made at ionizing dose rates as high as 10 Mrad/sec. In the final portion of the program, the optical transmission of fused silica and BeO was measured in the wavelength range 2000-3000 A during pulsed 5 and 7 MeV electron irradiation from the LINAC accelerator. The maximum time averaged ionizing dose rate was limited to 0.75 Mrad/sec due to accelerator limitations.

Palma, G. E.↗

Electron and proton damage coefficients in low-resistivity silicon

The electron and proton damage coefficients for low resistivity p-type boron-doped silicon were determined from minority-carrier lifetime measurements on bulk material and diffusion length measurements on solar cells. The bulk samples were irradiated with electrons at three energy levels (0.5, 1.5, and 2.5 MeV) using a Dynamitron. Lifetime measurements were made with a steady-state photoconductivity apparatus, and comparison measurements of diffusion length were obtained using the steady-state surface photovoltage method (Goodman, 1961). The diffusion-length damage coefficients increased with decreasing resistivity for boron-doped silicon; this dependence can be qualitatively accounted for using a two-level Hall-Shockley-Read model. The damage coefficients for solar cells were larger than for their bulk-material counterparts. The damage coefficient was apparently independent of the dislocation density in the 0.1 ohm-cm bulk samples and solar cells investigated.

Srour, J. R.↗

Hardening of MJS77 spacecraft against the Jupiter radiation belts

Results of the device characterization program to identify components of the Mariner Jupiter/Saturn spacecraft in need of radiation hardening to meet a total dose requirement of 5 trillion e/sq cm are presented. The parts to be tested, including bipolar transistors, JFETs, SCRs, CMOS devices, linear integrated circuits, Zener diodes and other radiation-sensitive parts, were identified by a worst case circuit analysis of the 20 major subsystems. The test samples were exposed to several levels of irradiation from a Dynamitron electron accelerator capable of producing a steady stream of electrons at energies up to 2.5 eV. The electrical parameters of the devices were measured immediately following irradiation to prevent annealing. CMOS devices and linear devices showed the most severe degradation in a moderate radiation environment, and significant degradation was produced at low current in bipolar transistors. Three methods used for screening a number of devices determined by circuit and shielding analyses to be unacceptable radiation-sensitive are described: diffusion and metallization lot screening; wafer lot screening; and irradiation-anneal screening.

W E Price↗

Total-dose radiation effects data for semiconductor devices, volume 2

Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

Price, W. E.↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗

Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a Cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose.

Martin, K. E.↗

Total-dose radiation effects data for semiconductor devices (1989 supplement)

Steady state, total dose radiation test data are provided for electronic designers and other personnel using semiconductor devices in a radiation environment. The data are presented in graphic and narrative formats. Two primary radiation source types were used: Cobalt-60 gamma rays and a Dynamitron electron accelerator capable of delivering 2.5 MeV electrons at a steady rate.

Martin, Keith E.↗

Gamma Energy Evaluation for Creation of Cd-111(sub m), In-113(sub m), and In-115(sub m) Isotopes

NASA Glenn Research Center is investigating nuclear reactions in deuterated materials exposed to bremsstrahlung photons with kinetic energies from 1-3MeV. Recent experiments used a continuous beam Dynamitron electron accelerator with a braking target. Electron beam energy loss verication was desired and experiments using cadmium and indium were completed which are known to transition to excited metastable states after exposure to bremsstrahlung photons. The gamma spin-up of Cd-111, In-113, and In-115 are with photon beam energies of 1017keV, 1024keV, and 941keV respectively. Recent tests corroborated published gamma energies using a beam energy loss of 62 to 74keV.

Benyo, Theresa L.↗

In-Situ Testing Methods for Mixed-Mode Harsh Environments

Future NASA missions are driving a need for instrumentation and space electronics that will operate at extreme temperatures, with low mass and extended deployments. This need results in devices that will experience dose damage at both low and high temperatures that will suppress annealing and induce accelerated wear out issues. Therefore, the ability to perform radiation tests on devices at temperature is critical. This paper analyses the methods and process to enable these test as developed at the JPL Dynamitron Facility. Since electronics are the radiation source for this facility, the steps to ensure parity with cobalt-60 testing are discussed. Also discussed are the implications for system level testing and mixed radiation mode testing for highly integrated and scaled devices.

Scheick, Leif Z↗

In Situ Testing Methods for Mixed-Mode Harsh Environments

A review of the radiation effects investigation capabilities of the JPL Dynamitron Accelerator Facility are discussed. A process for its use in performing total ionizing dose (TID) studies are outlined. The results of radiation effects in complicated test systems where device effects may occur due to local system irradiation are also presented.

Wong, A. T.↗