Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronic prognostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Stress testing on silicon carbide electronic devices for prognostics and health management.

Power conversion systems for energy storage and other distributed energy resource applications are among the drivers of the important role that power electronics plays in providing reliable electricity. Wide band gap semiconductors such as silicon carbide (SiC) and gallium nitride (GaN) will help increase the performance and efficiency of power electronic equipment while condition monitoring (CM) and prognostics and health management (PHM) will increase the operational availability of the equipment and thereby make it more cost effective. Voltage and/or temperature stress testing were performed on a number of SiC devices in order to accelerate failure modes and to identify measureable shifts in electrical characteristics which may provide early indication of those failures. Those shifts can be interpreted and modeled to provide prognostic signatures for use in CM and/or PHM. Such experiments will also lead to a deeper understanding of basic device physics and the degradation mechanisms behind failure.

42 ENGINEERING↗

Advanced Power Electronics Designs - Reliability and Prognostics (Keystone Project 1)

The primary deliverable for this project will be to construct a power electronics package utilizing an organic electrically insulating substrate material with a direct chip-to-chip interconnect technology and demonstrate superior thermal performance and greater reliability under thermal cycling, thermal aging, vibration, power cycling, and electrical high-potential evaluation over traditional packages.

47 OTHER INSTRUMENTATION↗

Advanced Power Electronics Designs - Reliability and Prognostics (Keystone Project 1)

The primary deliverable for this project will be to construct a power electronics package utilizing an organic electrically insulating substrate material with a direct chip-to-chip interconnect technology and demonstrate superior thermal performance and greater reliability under thermal cycling, thermal aging, vibration, power cycling, and electrical high-potential evaluation over traditional packages.

ADVANCED PROPULSION SYSTEMS↗

Advanced Power Electronics Designs - Reliability and Prognostics (Keystone Project 1)

The primary deliverable for this project will be to construct a power electronics package utilizing an organic electrically insulating substrate material with a direct chip-to-chip interconnect technology and demonstrate superior thermal performance and greater reliability under thermal cycling, thermal aging, vibration, power cycling, and electrical high-potential evaluation over traditional packages.

ADVANCED PROPULSION SYSTEMS,ENGINEERING↗

Advanced Power Electronics Designs - Reliability and Prognostics

The electrical interconnection and isolation design aspects within an inverter must also provide high thermal performance and thermomechanical reliability. In collaboration with ORNL, DuPont, and Indiana Integrated Circuits (IIC), NREL is evaluating new packaging materials and manufacturing techniques for wide-bandgap-based traction inverters. Thermal modeling and experimental evaluation revealed that an organic direct-bond-copper (ODBC) substrate has similar thermal resistance to traditional ceramic substrates. High-temperature thermal cycling has shown the ODBC substrates to have greater reliability than ceramic substrates which is a significant finding in the quest for low-cost, power-dense, high-temperature power electronics. IIC's direct chip-to-chip topside electrical connection will be attached to ODBC substrates and reliability evaluation for both technologies will be performed at NREL in Q4.

30 DIRECT ENERGY CONVERSION↗

Artificial Intelligence for Power Electronics in Electric Vehicles: Challenges and Opportunities

We report progress in the field of power electronics within electric vehicles has generally been driven by conventional engineering design principles and experiential learning. Power electronics is inherently a multidomain field where semiconductor physics and electrical, thermal, and mechanical design knowledge converge to achieve a practical realization of desired targets in the form of conversion efficiency, power density, and reliability. Due to the promising nature of artificial intelligence in delivering rapid results, engineers are starting to explore the ways in which it can contribute to making power electronics more compact and reliable. Here, we conduct a brief review of the foray of artificial intelligence in three distinct subtechnologies within a power electronics system in the context of electric vehicles: semiconductor devices, power electronics module design and prognostics, and thermal management design. The intent is not to report an exhaustive literature review, but to identify the state of the art and opportunities for artificial intelligence to play a meaningful role in power electronics design from a mechanical and thermal standpoint, as well as to discuss a few promising future research directions.

33 ADVANCED PROPULSION SYSTEMS↗

Prognostic Impact of External Beam Radiation Therapy in Patients Treated With and Without Extended Surgery and Intraoperative Electrons for Locally Recurrent Rectal Cancer: 16-Year Experience in a Single Institution

Purpose: To analyze prognostic factors associated with survival in patients after intraoperative electrons containing resective surgical rescue of locally recurrent rectal cancer (LRRC). Methods and Materials: From January 1995 to December 2011, 60 patients with LRRC underwent extended surgery (n=38: multiorgan [43%], bone [28%], soft tissue [38%]) or nonextended (n=22) surgical resection, including a component of intraoperative electron-beam radiation therapy (IOERT) to the pelvic recurrence tumor bed. Twenty-eight (47%) of these patients also received external beam radiation therapy (EBRT) (range, 30.6-50.4 Gy). Survival outcomes were estimated by the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Results: The median follow-up time was 36 months (range, 2-189 months), and the 1-year, 3-year, and 5-year rates for locoregional control (LRC) and overall survival (OS) were 86%, 52%, and 44%; and 78%, 53%, 43%, respectively. On multivariate analysis, R1 resection, EBRT at the time of pelvic rerecurrence, no tumor fragmentation, and non-lymph node metastasis retained significance with regard to LRR. R1 resection and no tumor fragmentation showed a significant association with OS after adjustment for other covariates. Conclusions: EBRT treatment integrated for rescue, resection radicality, and not involved fragmented resection specimens are associated with improved LRC in patients with locally recurrent rectal cancer. Additionally, tumor fragmentation could be compensated by EBRT. Present results suggest that a significant group of patients with LRRC may benefit from EBRT treatment integrated with extended surgery and IOERT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostics of damage accural in SSL luminaires and drivers subjected to HTSL accelerated aging

This paper will show an investigation of off-the-shelf luminaires with the focus on the LED electronic drivers, specifically the aluminum electrolytic capacitors (AECs), that have been aged using high temperature shelf life (HTSL) testing of 135°C in order to prognosticate the remaining useful life of the luminaires. Luminaires have the potential of seeing excessive temperatures when being transported across country or being stored in non-climate controlled warehouses. They are also being used in outdoor applications in desert environments that see little or no humidity but will experience extremely high temperatures during the day. This makes it important to increase our understanding of what effects being stored at high temperatures for a prolonged period of time will have on the usability and survivability of these devices. The U.S. Department of Energy has made a long term commitment to advance the efficiency, understanding and development of solid-state lighting (SSL) and is making a strong push for the acceptance and use of SSL products. In this work, the four AECs of three different types inside each LED electronic driver were studied. The change in capacitance and the change in equivalent series resistance (ESR) of the AECs were measured and considered to be a leading indication of failure of the LED system. These indicators were used to make remaining useful life predictions to develop an algorithm to predict the end of life of the AECs. The luminous flux of a pristine downlight module was also monitored using each LED electronic driver that was subjected to HTSL through the progression of the testing to determine a correlation between the light output of the lamp and the failing components of the LED electronic driver. Prognostic and Health Management (PHM) is a useful tool for assessment of the remaining life of electrical components and is demonstrated for AECs in this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prognostic Value of External Beam Radiation Therapy in Patients Treated With Surgical Resection and Intraoperative Electron Beam Radiation Therapy for Locally Recurrent Soft Tissue Sarcoma: A Multicentric Long-Term Outcome Analysis

Background: A joint analysis of data from centers involved in the Spanish Cooperative Initiative for Intraoperative Electron Radiotherapy was performed to investigate long-term outcomes of locally recurrent soft tissue sarcoma (LR-STS) patients treated with a multidisciplinary approach. Methods and Materials: Patients with a histologic diagnosis of LR-STS (extremity, 43%; trunk wall, 24%; retroperitoneum, 33%) and no distant metastases who underwent radical surgery and intraoperative electron radiation therapy (IOERT; median dose, 12.5 Gy) were considered eligible for participation in this study. In addition, 62% received external beam radiation therapy (EBRT; median dose, 50 Gy). Results: From 1986 to 2012, a total of 103 patients from 3 Spanish expert IOERT institutions were analyzed. With a median follow-up of 57 months (range, 2-311 months), 5-year local control (LC) was 60%. The 5-year IORT in-field control, disease-free survival (DFS), and overall survival were 73%, 43%, and 52%, respectively. In the multivariate analysis, no EBRT to treat the LR-STS (P=.02) and microscopically involved margin resection status (P=.04) retained significance in relation to LC. With regard to IORT in-field control, only not delivering EBRT to the LR-STS retained significance in the multivariate analysis (P=.03). Conclusion: This joint analysis revealed that surgical margin and EBRT affect LC but that, given the high risk of distant metastases, DFS remains modest. Intensified local treatment needs to be further tested in the context of more efficient concurrent, neoadjuvant, and adjuvant systemic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Modality Therapy Including Intraoperative Electron Irradiation for Locally Recurrent Colorectal Cancer

Purpose: To evaluate survival, relapse patterns, and prognostic factors in patients with colorectal cancer relapse treated with curative-intent therapy, including intraoperative electron radiation therapy (IOERT). Methods and Materials: From April 1981 through January 2008, 607 patients with recurrent colorectal cancer received IOERT as a component of treatment. IOERT was preceded or followed by external radiation (median dose, 45.5 Gy) in 583 patients (96%). Resection was classified as R0 in 227 (37%), R1 in 224 (37%), and R2 in 156 (26%). The median IOERT dose was 15 Gy (range, 7.5-30 Gy). Results: Median overall survival was 36 months. Five- and 10-year survival rates were 30% and 16%, respectively. Survival estimates at 5 years were 46%, 27%, and 16% for R0, R1, and R2 resection, respectively. Multivariate analysis revealed that R0 resection, no prior chemotherapy, and more recent treatment (in the second half of the series) were associated with improved survival. The 3-year cumulative incidence of central, local, and distant relapse was 12%, 23%, and 49%, respectively. Central and local relapse were more common in previously irradiated patients and in those with subtotal resection. Toxicity Grade 3 or higher partially attributable to IOERT was observed in 66 patients (11%). Neuropathy was observed in 94 patients (15%) and was more common with IOERT doses exceeding 12.5 Gy. Conclusions: Long-term survival and disease control was achievable in patients with locally recurrent colorectal cancer. Continued evaluation of curative-intent, combined-modality therapy that includes IOERT is warranted in this high-risk population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Foreword: Special Section on Multiphysics Aspects of Power Electronics Packaging - Power Die, Power Module, and Converter Level - Part 1

Power electronics are increasingly being used to condition electricity for a wide array of applications, such as transportation (on land, air, and water), data centers, radio frequency, directed energy, wind, solar, and grid-tied applications. To increase power density, performance, efficiency, and reliability and reduce cost, innovations and developments are needed in the multiphysics packaging of power electronics at a die, module, and converter level. This includes fundamental research and development related to emerging high-voltage, high-temperature, and high-switching-frequency power electronics; packaging materials; thermal materials and interfaces; fluid-based thermal management technologies; reliability; condition monitoring; and prognostics. To address these important aspects, this Special Section on Multiphysics Aspects of Power Electronics Packaging includes several articles to be published in two parts. More details are given below on the articles included in the first part.

condition monitoring↗

Power electronics reliability.

The project's goals are: (1) use experiments and modeling to investigate and characterize stress-related failure modes of post-silicon power electronic (PE) devices such as silicon carbide (SiC) and gallium nitride (GaN) switches; and (2) seek opportunities for condition monitoring (CM) and prognostics and health management (PHM) to further enhance the reliability of power electronics devices and equipment. CM - detect anomalies and diagnose problems that require maintenance. PHM - track damage growth, predict time to failure, and manage subsequent maintenance and operations in such a way to optimize overall system utility against cost. The benefits of CM/PHM are: (1) operate power conversion systems in ways that will preclude predicted failures; (2) reduce unscheduled downtime and thereby reduce costs; and (3) pioneering reliability in SiC and GaN.

25 ENERGY STORAGE↗

Prognostics and Health Management of Wind Turbines -- Current Status and Future Opportunities

The global wind industry has seen tremendous growth during the past two decades. However, the industry is challenged by premature component failures, which lead to increased turbine downtime and subsequently, cost of energy for wind power. To mitigate the impacts from these failures, the wind industry has been exploring various areas for improvements ranging from product design, new materials or lubricants, to operation and maintenance (O&M) practices. Condition-based maintenance or prognostics and health management (PHM) has been explored as one enabling technology for improving O&M practices. This chapter provides a brief overview of wind turbine PHM with a focus on operational data mining and condition monitoring of drivetrains. Some future research and development opportunities in wind turbine PHM are also briefly discussed.

17 WIND ENERGY↗

Foreword: Special Section on Multiphysics Aspects of Power Electronics Packaging—Power Die, Power Module, and Converter Level: Part 2

Power electronics are increasingly being used to condition electricity for a wide array of applications, such as transportation (on land, air, and water), data centers, radio frequency, directed energy, wind, solar, and grid-tied applications. Here, to increase power density, performance, efficiency, and reliability-as well as to reduce cost-innovations and developments are needed in the multiphysics packaging of power electronics at a die, module, and converter level. This includes fundamental R&D related to emerging high-voltage, high-temperature, and high-switching-frequency power electronics, packaging materials, thermal materials and interfaces, fluid-based thermal management technologies, reliability, condition monitoring, and prognostics. Latest developments in this area are published as a Special Section on Multiphysics Aspects of Power Electronics Packaging. The first part was published in the May 2024 issue of the IEEE Transactions on Components, Packaging and Manufacturing Technology (Volume 14, Issue 5). The second part of that Special Section is being published in this issue. A brief summary of the papers included in the second part are given below.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Module Precursors and Prognostics

This project focuses on finding and utilizing electrical properties (precursors) of power electronic devices and modules whose changes have strong correlations with different modes and levels of degradations in order to realize online and lightweight state of health evaluation and fault diagnosis. Results from this project will contribute to higher safety, reliability, and power density of power electronic components. The approaches mainly include reviewing academic literature and industry practices for state of the art precursor identification and extraction, accelerated life cycles (ALC) of various power modules to create different degradations in-house, and developing techniques for gate-driver-integratable precursor detection circuit. In FY24, the results includes two sets of definitively detected aging precursors (on-state resistance and gate threshold voltage) for two sets of power modules respectively, controlled accelerated lifetime cycling of multiple silicon carbide (SiC) metal-oxide-semiconductor field-effect transistor (MOSFET) modules, and the development and validation of a gate voltage detection system.

ADVANCED PROPULSION SYSTEMS↗

Machine Learning Approaches for Predicting Radiation Therapy Outcomes: A Clinician's Perspective

Radiation oncology has always been deeply rooted in modeling, from the early days of isoeffect curves to the contemporary Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) initiative. In recent years, medical modeling for both prognostic and therapeutic purposes has exploded thanks to increasing availability of electronic data and genomics. One promising direction that medical modeling is moving toward is adopting the same machine learning methods used by companies such as Google and Facebook to combat disease. Broadly defined, machine learning is a branch of computer science that deals with making predictions from complex data through statistical models. These methods serve to uncover patterns in data and are actively used in areas such as speech recognition, handwriting recognition, face recognition, “spam” filtering (junk email), and targeted advertising. Although multiple radiation oncology research groups have shown the value of applied machine learning (ML), clinical adoption has been slow due to the high barrier to understanding these complex models by clinicians. Here, we present a review of the use of ML to predict radiation therapy outcomes from the clinician's point of view with the hope that it lowers the “barrier to entry” for those without formal training in ML. We begin by describing 7 principles that one should consider when evaluating (or creating) an ML model in radiation oncology. We next introduce 3 popular ML methods—logistic regression (LR), support vector machine (SVM), and artificial neural network (ANN)—and critique 3 seminal papers in the context of these principles. Although current studies are in exploratory stages, the overall methodology has progressively matured, and the field is ready for larger-scale further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transformer Health Monitoring Using Dissolved Gas Analysis

As integral components of any power plant, transformers supply the generated electricity to the grid. However, a transformer’s cellulose-based paper insulation and the mineral oil in which it is immersed break down over time under standard operating conditions—or more rapidly due to potential faults within the system. As the transformer’s mineral oil breaks down, gases are released that can be measured and monitored. This technical brief exhibits a collection of diagnostic and prognostic techniques that utilities can adopt in lieu of labor-intensive periodic preventive maintenance routines. Furthermore, prognostic models have been incorporated using the latest version of the Institute of Electrical and Electronics Engineers (IEEE) standard (IEEE, 2019) for dissolved gas analysis (DGA), thus expanding it to include estimation of the time to maintenance. Overall, four different methodologies are explained, each of which aids in determining a transformer’s state of health. These methodologies include the Chendong model, the IEEE thermal life consumption model (IEEE, 2012), a diagnostic model for DGA, and a prognostic model for DGA that uses an autoregressive integrated moving average (ARIMA) model. An additional improvement for estimating missing system parameters by using monitoring data (i.e., a tool for parameter estimation utilizing Powell’s method) is presented, enabling the IEEE thermal life consumption model to benefit not only the collaborating power plant, but also the power industry at large.

24 POWER TRANSMISSION AND DISTRIBUTION↗