Search NASASearch

SEARCH · Search NASA

Results for “net metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

87 records · Page 2

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]

NuMI Graphite Target Fin Removal Assembly

Materials scientists want to study the irradiated graphite target from the Neutrino at the Main Injector (NuMI) beam line. In order to gather these irradiated graphite fins from the target canister, it will have to be done remotely. Therefore, a removal assembly will need to be created in order to do this efficiently and well. This project aims to make progressive steps towards deploying the final target removal assembly. Furthermore, calculations related to the removal assembly design were done, and tests were planned to discover further information about the feasibility of this design. The main result from this project is the deflection of the cantilever arm, which is 0.354 inches due to the weight of the beam and cutting tool. Additionally, more results of this project are the testing assembly CAD model and the feasibility of design. This project concludes that there is still more work that needs to be done for the removal assembly to be deployed, but there were foundational steps that were made in the implementation of this design. Finally, there should be further steps and tests to determine the feasibility of this removal assembly.

Malovski, Azra [NIU, DeKalb]

Eddy Covariance Theory: A Review

Eddy covariance (EC), the gold standard for measuring ecosystem scale gas and heat exchanges, has transformed our understanding of the breathing of the biosphere, and thus global change biology. Despite numerous methodological improvements and insights gained from the technique, the community faces persistent challenges that have been present since the first EC measurements. Here, we review the theoretical developments underpinning EC. We present theoretical developments in four important areas that have relevance to EC measurements of the net ecosystem exchanges (NEE) of gases and heat from a single tower: (i) measuring the total vertical flux density, (ii) flux attenuation, (iii) coordinate rotations, and (iv) energy balance closure. Persistent problems with EC measurements, such as the inability to close the energy budget, led us to identify two priorities for revisiting the theory underlying: (i) sensible heat flux calculations, and (ii) constraining the mean vertical wind velocity. We present a framework for improved calculation of sensible heat flux derived from first principles of fluid mechanics and thermodynamics that considers coupled heat and mass transfer so that conservation of both is obeyed. These refinements are motivated by the need for unbiased measurements of energy and mass transfer between the land surface and atmosphere for ecosystem research and to validate satellite observations and land surface models.

ecosystem fluxes

Computing the Critical Temperature of the Affine-Transformed $D=3$ Ising Model Using Masked Autoregressive Flow

The simple Ising model provides a rich environment to build and study lattice field theories. As part of an ongoing project to construct a conformal field theory (CFT) on an arbitrarily curved manifold, in this work we develop methods to measure the critical temperature $β_c$ of the affine-transformed Ising model on the face-centered cubic (FCC) lattice. The main challenge in this endeavor is finding a computationally efficient and accurate method of interpolating and extrapolating Monte Carlo observables with respect to coupling coefficients and temperature. Herein, we compare two such methods. A traditional statistical approach uses the multiple histogram (MH) method, while a newer machine learning approach uses a masked autoregressive flow (MAF) to estimate the underlying probability density function of a set of observables. While the MH method is specifically designed to interpolate and extrapolate Monte Carlo observables, we find that MAF is a viable alternative for measuring $β_c$ with a computational cost that scales more favorably. Furthermore, we comment on additional advantages of MAF relevant to our work, such as extrapolating in system volume.

Svenson, Kai [Texas U.]

Time Correlations from Steady-State Expectation Values

Recovering properties of correlation functions is typically challenging. On the one hand, experimentally, it requires measurements with a temporal resolution finer than the system’s dynamics. On the other hand, analytical or numerical analysis requires solving the system evolution. Here, we use recent results of quantum metrology with continuous measurements to derive general lower bounds on the relaxation and second-order correlation times that are both easy to calculate and measure. These bounds are based solely on steady-state expectation values and their derivatives with respect to a system parameter, and can be readily extended to the autocorrelation of arbitrary observables. We validate our method on two examples of critical quantum systems: a critical driven-dissipative resonator, where the bound matches analytical results for the dynamics, and the infinite-range Ising model, where only the steady state is solvable, and thus the bound provides information beyond the reach of existing analytical approaches. Our results can be applied to the experimental characterization of ultrafast systems and to the theoretical analysis of many-body models whose dynamics are hard to compute.

Górecki, Wojciech [INFN, Pavia] (ORCID:00000001991

Getting Warmer: IceCube Nears Freeze Out

IceCube has recently detected a diffuse population of high-energy neutrinos arising from the Milky Way. We use this high-significance detection to place new limits on dark matter (DM) annihilation to neutrinos with two complementary approaches. The first method uses the background-subtracted Galactic longitude distribution of shower events to place a conservative bound on the DM annihilation cross section that does not rely on any assumed Galactic cosmic ray emission model; the resulting limits on the velocity-averaged annihilation cross section improve upon existing bounds by factors of a few. The second method uses the template-dependent neutrino energy spectra from the Inner Galaxy, inferred under different Galactic cosmic ray emission models. This complementary approach shows that the inferred Galactic neutrino intensities are already sensitive to DM contributions near the thermal-relic benchmark for a range of TeV-scale DM masses, though this comparison is more model-dependent. Our results demonstrate that measurements of diffuse Galactic neutrino emission can be used as a powerful probe of DM annihilation into neutrinos. Future observations with IceCube-Gen2 and KM3NeT will substantially extend this sensitivity, potentially allowing a decisive test of the thermal freeze-out mechanism with Galactic neutrino observations.

Mukhopadhyay, Mainak [Fermilab; Chicago U., KICP;

Mechanics and Cooling of the CMS Phase-II Tracker Barrel

The CMS upgrade for the High-Luminosity LHC (HL-LHC) era will allow for an incredibly high rate of data collection, to be used in the next generation of precision measurements and searches for beyond the standard model physics. A key element of this upgrade is the full replacement of the silicon strip tracker to enable level-1 triggering on track level primitives, produced by pixel-strip (PS) and strip-strip (2S) modules, tiled together to form the new detector. Mechanically supporting and cooling these modules is not trivial, as material budget in the tracker volume is highly constrained, and as the modules accrue radiation damage they risk becoming entirely non-functional if the silicon sensors are not sufficiently cooled. To address this, each region of the tracker has a bespoke solution for housing and cooling their modules, mostly depending on carbon-fiber and carbon-foam structures, with dual phase CO2 cooling. For the most central part of the tracker, the Flat Barrel with PS modules (Flat TBPS) covers the pseudorapidity range out to $|\eta|=0.4$, and the mechanical structures are manufactured, assembled, and tested entirely by Fermilab and UC Davis. This presentation will describe the intense design and testing requirements for these components, and how they will ensure strong performance of the tracker through the HL-LHC era.

Cosby, Christopher [Fermilab]

Enhancing Coherence Limits in Superconducting Quantum Systems for Computing and Sensing

This talk will highlight recent efforts at the SQMS Center to develop qudit-based quantum computing architectures using superconducting three-dimensional (3D) cavities, as well as the use of these ultra-coherent cavities for quantum sensing. I will present systematic studies of materials and devices aimed at identifying and mitigating the dominant sources of decoherence—including two-level systems (TLS), quasiparticles, and other noise mechanisms—in both transmons and 3D cavities. These investigations include microwave loss characterization of niobium, tantalum, aluminum, their native oxides, and substrate materials such as silicon and sapphire. By combining measurements on qubits and cavities, we disentangle subsystem-specific loss mechanisms and establish a hierarchy of mitigation strategies, leading to transmon coherence times exceeding one millisecond. I will also discuss studies of quasiparticle dynamics, including quasiparticle bursts observed in qubits operated both above ground and at the Gran Sasso underground laboratory, and the observation that applied magnetic fields can suppress temporal T₁ fluctuations. Building on these advances, we demonstrate a record-coherence two-cell cavity-qudit system with coherence times exceeding 20 milliseconds. Leveraging tunable sideband interactions together with error-resilient protocols, including measurement-based error correction and post-selection, we achieve high-fidelity quantum state control, including the preparation of Fock states up to N=20 with fidelities above 95% and the generation of high-fidelity two-mode entangled states. Finally, I will discuss how these ultra-coherent quantum systems are enabling emerging quantum sensing applications, including searches for dark matter and gravitational waves.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]

Precise Modeling of a Complex Solenoidal Magnetic Field Using a Combination of Analytic Functions and a PINN

We demonstrate an iterative approach to modeling a sparsely measured magnetic field in a large-bore solenoid. This approach uses a hybrid of traditional and machine learning techniques. The traditional technique is a linear least-squares fit using a series solution to Laplace's equation, while the machine learning technique involves the training of a physics-informed neural network (PINN) on the least-squares fit residuals. We use a newly defined activation function "DELTAsnake," a modification to the snake activation function proposed by Ziyin et al. that allows for stronger curvature and non-monotonicity. The combined model approximately obeys Maxwell's equations to a level sufficient for producing high quality physics simulations and analysis. Our approach is applied to a highly realistic calculation of the expected magnetic field in the Mu2e experiment's Detector Solenoid which includes a simple model for the expected statistical measurement uncertainties. Using ten toy measurement simulations, we demonstrate the capabilities of our model in comparison to the least-squares method alone; the least-squares method alone results in a reduced chi-squared statistic of ${2.15 \pm 0.01}$, while our approach improves the reduced chi-square to ${1.034 \pm 0.005}$. Furthermore, for an average toy simulation, we show that the range of the RMS of the three field component residuals reduces from ${0.07-0.37}$ Gauss to ${0.05-0.07}$ Gauss. We find that this novel method is robust against a realistic systematic uncertainty deriving from Hall probe calibration bias and can be used to significantly reduce the number of measurements required to achieve an accurate model.

Kampa, Cole [Caltech] (ORCID:0000000192972920)

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN

Systematic Construction of Time-Dependent Hamiltonians for Microwave-Driven Josephson Circuits

Time-dependent electromagnetic drives are fundamental for controlling complex quantum systems, including superconducting Josephson circuits. In these devices, accurate time-dependent Hamiltonian models are imperative for predicting their dynamics and designing high-fidelity quantum operations. Existing numerical methods, such as black-box quantization (BBQ) and energy-participation ratio (EPR), excel at modeling the static Hamiltonians of Josephson circuits. However, these techniques do not fully capture the behavior of driven circuits stimulated by external microwave drives, nor do they include a generalized approach to account for the inevitable noise and dissipation that enter through microwave ports. Here, we introduce numerical techniques that leverage classical microwave simulations, efficiently executable in finite-element solvers, to obtain the time-dependent Hamiltonian of microwave-driven superconducting circuits with arbitrary geometries under charge, flux, or mixed electromagnetic modulation. Importantly, our techniques do not rely on a lumped-element description of the superconducting circuit, in contrast to previous approaches to tackling this problem. We demonstrate the versatility of our approach by characterizing the driven properties of realistic circuit devices in complex electromagnetic environments, including coherent dynamics due to charge and flux modulation, as well as drive-induced relaxation and dephasing. Our techniques offer a powerful toolbox for optimizing circuit designs and advancing practical applications in superconducting quantum computing.

Lu, Yao [Yale U.; Yale U. (main); Fermilab] (ORCID

Qualifying LaBr3:Ce+Sr detector performance for the Mu2e experiment at Fermilab Using the ELBE Accelerator

A LaBr3:Ce+Sr detector will be used to measure the stopped muon captures at the Mu2e experiment at Fermilab. It has been benchmarked in a test beam experiment performed at the ELBE electron accelerator located at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. ELBE’s pulsed bremsstrahlung beam line was set to deliver an average γ -ray energy of between 4–5 MeV. The detector response was mapped to match Mu2e beam conditions, including rates up to 1 Mcps, energy flux, and time structure. A radioactive calibration source was used to mimic the characteristic 1808.7 keV γ -ray, emitted during the atomic muon nuclear capture in the Mu2e aluminum stopping target. The detector energy resolution was measured as a function of the average energy flux: up to 1 TeV/s for 0.34 s, the steady-operation beam-on time and up to 4 TeV/s for 5 ms to get a conservative estimate of the effect of high intensity Mu2e beam fluctuations. The PMT gain variation as a function of the beam spill length and average intensity has been parametrized and corrected for. When a PMT gain correction corresponding to the average beam-spill intensity is applied, the residual effect of beam intensity fluctuations around the average degrades the energy resolution, σ E γ /E γ , at 1808.7 keV from 0.66% to 0.83%.

Huang, Shihua [Purdue U., West Lafayette]

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Neutron detector response modeling in NOvA

Neutrons can present a significant challenge for neutrino experiments in which energy reconstruction is critical. With the ability to escape detection completely and with a weak correlation between their kinetic energy and any eventual energy deposition, it is difficult to fully account for neutrons produced in neutrino interactions. This in turn leads to significant model dependence when evaluating neutron-related systematic uncertainties. The NOvA experiment is a long-baseline neutrino oscillation experiment with a high-statistics sample of antineutrino data collected by its near detector. We report an excess relative to data of simulated neutron candidates with low energy depositions when using standard Geant4 physics lists. The simulation excess is traced to an overabundance of secondary photons produced from interactions of neutrons with kinetic energy greater than \SI{20}{\mega\eV}. Improved agreement with data is obtained by applying the data-driven neutron-on-carbon \menate model for neutrons between \SI{20}{\mega\eV} and ${\sim}$\SI{100}{\mega\eV}. With \menate, the residual oversimulation is more uniform across the calorimetric neutron energy spectrum, suggesting possible overproduction of primary neutrons by the GENIE neutrino interaction generator. These results motivate the adoption of \menate-supplemented Geant4 simulation as the nominal simulation in the production of future \nova simulation.

Abubakar, S.

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE

The DESI Single Fiber Lens Search. I. Four Thousand Spectroscopically Selected Galaxy–Galaxy Gravitational Lens Candidates

We present 4110 strong gravitational lens candidates, 3887 of which are new discoveries, selected from a sample of 5,837,154 luminous red galaxies (LRGs) observed with the Dark Energy Spectroscopic Instrument (DESI). Candidates are identified via the presence of background ionized oxygen [O II ] nebular emission lines in the foreground LRG spectra, which may originate from the lensing of higher-redshift star-forming galaxies. Using the measured foreground redshift, background redshift, and integrated flux of the background [O II ] doublet, we integrate over impact parameters to compute the probability that each candidate is a lens. We expect 53% of candidates to be true lenses with Einstein radii ranging from 0$^{''}_.$1–4", which can be confirmed with high-resolution imaging. Confirmed strong lenses from this sample will form a valuable cosmological data set, as strong gravitational lensing is the only method to directly measure dark matter halo substructure at cosmological distances. We independently recover the host of the multiply imaged gravitationally lensed type Ia supernova iPTF16geu. Monitoring these lenses for future multiply lensed transients will enable (a) H 0 measurements via time-delay cosmography and (b) substructure measurements via flux ratios.

Karp, Juliana S. M. [Univ. of Washington, Seattle,