Search NASASearch

SEARCH · Search NASA

Results for “high-temperature refractory thermal energy storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,262 records · Page 3

Hybrid Power Purchase Agreements for Flexible 24/7 Energy Delivery – A Comprehensive Review of Current Practices and Research Pathways

Power Purchase Agreements (PPAs) are becoming increasingly preferred among large energy consumers, such as data centers, to secure cost-effective energy and meet accelerating demand growth. Traditionally, variable renewable energy (VRE)-based PPAs operate on a pay-as-produced basis, balancing supply and demand for a relatively longer duration (e.g., annually). However, the focus is shifting toward matching supply and demand on an hourly basis to fully meet energy needs. This shift requires the integration of flexible energy resources, such as hydropower, thermal generation, and energy storage, to complement VRE sources like wind and solar, forming the foundation for 24/7 PPA. This work contributes by: (i) reviewing emerging market trends and current practices in PPA procurement, supported by data on PPA prices and technology portfolios; (ii) synthesizing the existing literature on modeling approaches for contract pricing, quantities, hybrid resource procurement, and risk management in 24/7 PPA design, while identifying key research gaps; and (iii) proposing an integrated 24/7 PPA design framework along with two contracting mechanisms from the perspectives of both PPA providers and consumers. The proposed framework highlights critical modeling challenges, risk-allocation issues, and future research opportunities for 24/7 PPA design.

24/7

Robust and tunable oxide nanoscrolls for solar-driven H 2 generation and storage

Hydrogen gas is a promising alternative to fossil fuels due to its high energy output and environmentally safe byproducts. Various morphologies of photocatalytic materials have been explored for high-efficiency H 2 production, for instance, quasi-1D nanoscroll structures that provide a larger surface-to-volume ratio. Recently, we predicted layer-by-layer formation of stable oxide nanoscrolls directly from dichalcogenide precursors, eliminating the need for costly formation of two-dimensional oxides for a roll-up synthesis of nanoscrolls. Here, in this study, we evaluate the suitability of those oxide nanoscroll materials—MoO 3 , WO 3 , PdO 2 , HfO 2 , and GeO 2 —for solar-driven photocatalytic H 2 production and storage. Using excited state theory coupled with Bethe–Salpeter equation simulations, we discern their electronic and optical properties as a function of interlayer scroll spacing and find them to be highly conducive for solar-driven photocatalysis. Additionally, using ab initio molecular dynamics simulations, we show that they are also suitable for H 2 storage as the nanoscrolls exhibit an effective trapping of hydrogen, even in the presence of defects and vacancies in the oxides. This work thus demonstrates the discovery of robust and tunable oxide nanoscrolls as materials for advancing solar-driven hydrogen technologies.

Chemical compounds

Techno-Economic Evaluation of a 600MW Pumped Storage Hydropower Plant using the Pumped Storage Hydropower Valuation Tool

This paper presents a techno-economic evaluation of the proposed 600 MW, 8-hour Craig – Hayden pumped storage hydropower project using the U.S. Department of Energy’s Pumped Storage Hydropower Valuation Tool. The analysis integrates plant technical characteristics, regional grid conditions, and market-based operating assumptions to quantify stacked value streams from energy arbitrage, capacity, ancillary services, transmission congestion relief, and reliability. Both price taker and price influencer frameworks are applied to examine the impact of market participation and system interactions on lifecycle economic performance using Benefit - Cost Analysis and Multi - Criteria Decision Analysis. The results show that the price taker approach provides higher revenue estimates based on exogenous price signals, while the price influencer approach captures production cost savings, renewable curtailment reduction, and market price formation, yielding more conservative but system-representative outcomes. The study demonstrates the strategic value of long-duration PSH for enhancing operational flexibility, resource adequacy, and grid reliability in a high-renewable Western Interconnection.

Bhattacharyya, Arjun [ORNL] (ORCID:000900060976046

Extreme confinement of hydrogen gas within fullerenelike nanoporous carbon

Nanoporous carbons and carbon nanostructures can store hydrogen at cryogenic temperatures but lack the volumetric and gravimetric capacity to be industrially significant. Recent inelastic neutron scattering experiments suggest a highly dense phase of hydrogen at temperatures well above the melting point of solid hydrogen. However, it remains unclear how pore geometry and intermolecular interactions enable these dense phases to exist, with dispersion (van der Waals) or electrostatic/induction suggested to be the key effects in slit and curved pores but their relative contributions have yet to be quantified. In this paper, we perform benchmark electronic structure calculations allowing the interactions between planar and curved aromatic molecules with hydrogen to be accurately determined. Dispersion was found to dominate over electrostatic and inductive effects with some many-body charge transfer (Dobson type-A) effects needed to capture the most highly curved structures. Density functional methods that include type-A many-body effects were found to accurately describe the intermolecular interactions at a fraction of the cost of coupled-cluster simulations and these approaches were used to calculate the energies inside large carbon bowl and slit pores. The interaction energies inside the bowl pores were found to depend on the orientation of the hydrogen molecule. This rotational barrier, modeled as a quantum hindered rotor, could reproduce the peak splitting observed in inelastic neutron scattering experiments, with weak splitting arising from bowl-like fullerene pores and strong splitting from highly confining nanotubelike pores. Increasing the fraction of such curved pores in nanoporous carbons may therefore offer a pathway to enhance their hydrogen-storage capacity. Moreover, the preferential adsorption of ortho hydrogen on nanotubelike pores could enable the storage of high-density hydrogen without the need to remove heat produced during the ortho-para hydrogen conversion.

36 MATERIALS SCIENCE

Glauber’s Salt Composites for HVAC Applications: A Study on the Use of the T-History Method with a Modified Data Evaluation Methodology

Phase change materials (PCMs) can be utilized in buildings for peak load shifting in air conditioning systems, and the use of salt hydrate-based PCMs can reduce the cost of thermal energy storage devices. Glauber’s salt is an economical salt hydrate PCM with a melting point of around 32 °C. However, the desired melting range typically falls between 18 and 22 °C for building air conditioning applications. Although many researchers have characterized Glauber’s salt and its composites with modified melting points, enthalpy–temperature curves for composites of Glauber’s salt and NaCl are unavailable. In this study, we report the melting and solidification enthalpy–temperature curves for two different composites of Glauber’s salt and NaCl with a melting point of 21 °C obtained by the T-history method. Both composites contain NaCl to suppress the melting point, borax to reduce supercooling, and sodium polyacrylate as a thickener to enhance cyclic stability. The first composite with 12 wt.% NaCl demonstrated 139 kJ·kg−1 of latent heat of fusion, and the second composite with 9 wt.% NaCl demonstrated 171 kJ·kg−1. Both the composites have high volumetric energy densities compared to their organic counterparts with similar melting points.

Chemistry

Breaking the Energy Barrier of Heavy Metal Ion Diffusion in Micropores with Mesoporous 3D Graphene for Fast and Efficient Cu2+ Removal

Efficient removal of heavy metals from water critically depends not only on adsorption capacity but also on ion diffusion kinetics and the associated energy barriers. In conventional carbon adsorbents, severe diffusion confinement within micropores restricts ion transport, resulting in sluggish adsorption kinetics and large apparent activation energies despite high specific surface areas. Here, we demonstrate that this fundamental limitation is overcome by engineering meso/macroporous architectures in the 3D graphene materials synthesized via our discovered alkali-metal reactions with\\\\r\\\\n2\\\\r\\\\nCO. The unique 3D graphene materials possess defect-rich graphene frameworks with interconnected meso/macroporous networks, exhibiting simultaneously high surface area and greatly enhanced meso/macropore volume that enable efficient access to adsorption sites. As a result, the Cu2+ adsorption on 3D graphene proceeds with very low activation energies (4.98 kJ mol–1), which is almost 4 times smaller than on activated carbon (23.1 kJ mol–1). This finding offers a promising platform for efficient and sustainable water purification.

25 ENERGY STORAGE

Cation-Diffusive Carbon Interlayers Stabilize Na Metal and Double the Current in Na-S Redox-Flow Batteries for Grid-Scale Energy Storage

The sodium-sulfur nonaqueous redox-flow batteries (Na-S NARFBs) using earth-abundant elements are highly attractive due to the low material cost and improved energy density for grid-scale energy storage. However, the low current performance, poor Na0/Na+ redox kinetics, and Na dendrite growth pose severe challenges. We introduce cation-diffusive layers (CDLs): thin and Na+ affinitive interlayers at the Na anode that direct Na+ transport and stabilize Na deposition. Benchmarking three archetypal materials—carbon paper (CP), glass microfiber paper (GF), and foam—across Na-Na and Na-Cu, and Na-S cells identifies CP as the optimum. CP reduces symmetric cell overpotential by more than 70%, achieves 98% Na plating-stripping efficiency, and doubles the Na-S cell current density from 0.5 to 1.0 mA cm−2 without sacrificing capacity or efficiency. Ex situ electrochemical and SEM/XPS analysis, combined with molecular dynamics (MD) studies, reveal that electron-rich carbon fibers disperse supporting salt aggregates, enrich near-surface Na+ density, and create ion transport pathways for fast Na0/Na+ exchange while mitigating membrane degradation. Because of the ion-centric mechanism, CDLs can be generalized to other metal-anode designs. Further, this work establishes CDL design rules—cationic affinity and appropriate micro/nanostructure—as a simple, scalable route to high-current, durable metal-anode flow batteries.

Wu, Wenda [ORNL] (ORCID:000900033307687X)

Development of Electrolytes under Lean Condition in Lithium–Sulfur Batteries

Lithium–sulfur (Li–S) batteries stand out as one of the promising candidates for next-generation electrochemical energy storage technologies. A key requirement to realize high-specific-energy Li–S batteries is to implement low amount of electrolyte, often characterized by the electrolyte/sulfur (E/S) ratio. Low E/S ratio aggravates the known challenges for Li–S batteries and introduces new ones originated from the high concentration of polysulfides in limited electrolyte reservoir. Here, in this review, the connections between the fundamental properties of electrolytes and the electrochemical/chemical reactions in Li–S batteries under lean electrolyte condition are elucidated. The emphasis is on how the solvating properties of the electrolyte affect the fate of polysulfides. Built upon the mechanistic analysis, different strategies to design lean electrolytes to improve the overall process of Li–S reactions and Li anode protection are discussed.

25 ENERGY STORAGE

Metal–Organic Framework-derived Atomic Metal Sites Promoting Sulfur Cathode for All-Solid-State Lithium–Sulfur Batteries

All-solid-state lithium–sulfur batteries (ASSLSBs) offer high energy density and intrinsic safety; however, they still face major challenges, including sluggish redox kinetics and poor sulfur utilization. Incorporating conductive materials into sulfur cathodes is an effective strategy to mitigate these limitations. Here, a highly conductive cobalt–nitrogen–doped carbon (Co–NC) derived from a metal–organic framework (MOF) is introduced to accelerate charge transfer and promote reversible sulfur conversion. Co−NC provides atomically dispersed Co–N sites and conductive carbon pathways that correlate with improved charge transfer, sulfur utilization, and rate capability. Co–NC@S cathode delivers 1499 mAh g–1 at C/20 with a high sulfur loading (5 mg cm–2) and retains 1292 mAh g–1 after five cycles (vs 443 mAh g–1 without Co–NC). Moreover, Co–NC derived ASSLSB achieves 903 mAh g–1 at 5C at 60 °C. This work provides a practical and effective approach to develop high energy, high-rate ASSLSBs.

25 ENERGY STORAGE

Design and Synthesis of Cubic K 3−2 x Ba x SbSe 4 Solid Electrolytes for K–O 2 Batteries

Developing K-ion conducting solid-state electrolytes (SSEs) plays a critical role in the safe implementation of potassium batteries. In this work, a chalcogenide-based potassium ion SSE is reported, K 3 SbSe 4 , which adopts a trigonal structure at room temperature. Single-crystal structural analysis reveals a trigonal-to-cubic phase transition at the low temperature of 50 °C, which is the lowest among similar compounds and thus provides easy access to the cubic phase. The substitution of barium for potassium in K 3 SbSe 4 leads to the creation of potassium vacancies, expansion of lattice parameters, and a transformation from a trigonal phase to a cubic phase. As a result, the maximum conductivity of K 3−2x Ba x SbSe 4 reaches around 0.1 mS cm −1 at 40 °C for K 2.2 Ba 0.4 SbSe 4 , which is over two orders of magnitude higher than that of undoped K 3 SbSe 4 . This novel SSE is successfully employed in a K–O 2 battery operating at room temperature where a polymer-laminated K 2.2 Ba 0.4 SbSe 4 pellet serves as a separator between the oxygen cathode and the potassium metal anode. Effective protection of the K metal anode against corrosion caused by O 2 is demonstrated.

25 ENERGY STORAGE

Advanced LiFSI-LiPF6 Electrolyte for Wide-Temperature and Thermally Stable Lithium-Ion Batteries

A new optimized LiFSI–LiPF6 dual-salt controlled-solvation electrolyte (E-DS) is demonstrated to enable practical graphite||LiNi0.8Mn0.1Co0.1O2 cells (˜4.0 mAh cm?²) to achieve exceptional performance and safety under extreme conditions. By optimizing anion coordination with the smaller, more dissociating FSI? anion, the E-DS forms ultrathin, dense, and inorganic-rich electrode/electrolyte interphases that dramatically suppress solvent decomposition, transition-metal dissolution, and surface reconstruction compared to the conventional LiPF6/carbonate electrolyte. Consequently, E-DS cells deliver >78% capacity retention after 300 cycles at 60 °C, retain fast discharging capacity at 30 °C, and operate effectively at -20 °C. Most strikingly, fully charged full cells with E-DS, even under overcharging to 4.8 V, show a lower heat evolution in stable formulations — transforming a traditionally unstable high-voltage/high-temperature configuration into an intrinsically safe state. This work establishes a new benchmark for carbonate-containing electrolytes, simultaneously achieving high energy density, fast-discharging capability, wide-temperature operation (-20 to 60 °C), and outstanding thermal safety in nickel-rich lithium-ion batteries.

electrode/electrolyte interphase

Methods and recommendations for large-scale deflagration testing of battery energy storage system enclosures

UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.

Gaudet, Benjamin [UL Solutions] (ORCID:00090006419

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE