Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Developmental Hardware Testing Results and Forward Plans for the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Developmental Hardware Testing Results and Forward Plans for Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Standard Candles for Supernova Neutrino Detection at DUNE

The Deep Underground Neutrino Experiment (DUNE) far detector is sensitive to $\mathcal{O}(10)$ MeV electron neutrinos through $ν_e$ charged-current reaction with argon. This capability is a unique window into the $ν_e$ component of a Galactic core-collapse supernova flux. Extracting the properties of the supernova spectrum is, however, limited by the poorly-known $ν_e$-Ar cross section. We propose a data-driven strategy that leverages $^8$B solar neutrinos and muon-decay-at-rest neutrinos as standard candles for this process. These calibration samples constrain both the low-energy and high-energy components of the cross section relevant for supernova detection. Our method reduces the reliance on nuclear models, which can bias the extraction of the spectral parameters by as much as 300$\%$.

Cheng, Ting [Fermilab]↗

Docking the Mars 2020 Perseverance Robotic Arm

The Mars 2020 Perseverance Rover includes an innovative Sample Caching Subsystem (SCS). Two key features of SCS are the ability to collect and process rock and regolith samples for possible future return to Earth and the ability to switch between different types of drill bits for coring rocks, abrading rocks, and collecting regolith. These capabilities are enabled by a Corer mounted on the end of a Robotic Arm and a Bit Carousel mounted on the front of the rover body. Beneath the Bit Carousel, a smaller Sample Handling Arm can insert and remove sample tubes from sampling bits in the carousel. For the Corer to interface with the Bit Carousel so that it can exchange drill bits and hand off rock samples, the Robotic Arm must maneuver the Corer to dock with the Bit Carousel. Docking serves two primary purposes: it precisely aligns the Corer with the hardware inside the Bit Carousel, and it applies enough preload between the Corer and the Bit Carousel to make them stay aligned through the process of bit exchange.The docking assembly consists of four concave alignment cones mounted on a large rotating ring, through the center of which the drill can exchange bits and samples with the Bit Carousel. The coring drill includes four alignment posts which mate with the four cones on the dock. Docking uses an algorithm we call “Force-Corrected Docking”, which means it iteratively reads the force/moments reported by the FTS, performs a small motion to reduce sideload and moments while increasing preload, and repeats until reaching a deadband around the target preload. Because docking is a critical function for SCS, the dock hardware and algorithm have been tested thousands of times over 7 years in various stages of development. The culmination of this work is a reliable docking system which has been demonstrated and used in flight.

Warner, Antonia↗

Metadata Entry Optimization for NASA's Biological Institutional Scientific Collection (NBISC)

The NASA Biological Institutional Sample Collection (NBISC) at NASA’s Ames Research Center is a critical resource housing non-human samples collected from spaceflight missions and ground analog studies, primarily consisting of specimens from rats, mice, and select microbes. The primary objective of NBISC is to systematically receive, document, preserve, and facilitate access to these samples for the global scientific community. NBISC promotes international collaboration and maximizes the return on investment for precious tissues from spaceflight and analog experiments. Researchers can request physical samples through an online request form and subsequent written proposal review process. This study addresses two core research objectives: streamlining the NBISC sample lifecycle processes and strategizing for managing an influx of 50,000 tissue samples from a series of cosmic radiation analog experiments carried out at the NASA Space Radiation Laboratory (NSRL) by Drs. Eleanor Chang (Lawrence Berkeley Laboratory) and Polly Blakely (SRI). The Chang/Blakely studies investigated Harderian gland (HG) tumorigenesis in mice exposed to low dose and LET radiation comprising 8 different exposure protocols in over 4000 mice. NBISC sample metadata is stored in a Laboratory Information Management System (SLIMS). To streamline sample data entry, we customize python scripts using information extracted from the individual experimental protocols. The scripts automate entry into multiple SLIMS data fields including protocol name, unique sample barcode, tissue and sub-tissue information, freezer location, sample preservation method, etc. The semi-automated procedure significantly decreases the time spent on data entry by several orders of magnitude. Automation and data organization are essential, as they free up time for curation and promotion of the collection which, in turn, increase the accessibility of samples to the broader research community. NBISC benefits from streamlined data ingestion, and the methodologies developed here are applicable to other projects which use SLIMS including the NASA Biospecimen Sharing Program and GeneLab. As of Fall 2023, plans include transferring sample data from SLIMS to public facing repositories (OSDR and NLSP), expanding the reach of the Chang/Blakely sample collection. The Human Research Program Space Radiation Element plans to transfer non-human tissues from many more investigations to NBISC in the coming year.

Sample Repository↗

Metadata Entry Optimization For NASA's Biological Institutional Scientific Collection (NBISC)

The NASA Biological Institutional Sample Collection (NBISC) at NASA’s Ames Research Center is a critical resource housing non-human samples collected from spaceflight missions and ground analog studies, primarily consisting of specimens from rats, mice, and select microbes. The primary objective of NBISC is to systematically receive, document, preserve, and facilitate access to these samples for the global scientific community. NBISC promotes international collaboration and maximizes the return on investment for precious tissues from spaceflight and analog experiments. Researchers can request physical samples through an online request form and subsequent written proposal review process. This study addresses two core research objectives: streamlining the NBISC sample lifecycle processes and strategizing for managing an influx of 50,000 tissue samples from a series of cosmic radiation analog experiments carried out at the NASA Space Radiation Laboratory (NSRL) by Drs. Eleanor Chang (Lawrence Berkeley Laboratory) and Polly Blakely (SRI). The Chang/Blakely studies investigated Harderian gland (HG) tumorigenesis in mice exposed to low dose and LET radiation comprising 8 different exposure protocols in over 4000 mice. NBISC sample metadata is stored in a Laboratory Information Management System (SLIMS). To streamline sample data entry, we customize python scripts using information extracted from the individual experimental protocols. The scripts automate entry into multiple SLIMS data fields including protocol name, unique sample barcode, tissue and sub-tissue information, freezer location, sample preservation method, etc. The semi-automated procedure significantly decreases the time spent on data entry by several orders of magnitude. Automation and data organization are essential, as they free up time for curation and promotion of the collection which, in turn, increase the accessibility of samples to the broader research community. NBISC benefits from streamlined data ingestion, and the methodologies developed here are applicable to other projects which use SLIMS including the NASA Biospecimen Sharing Program and GeneLab. As of Fall 2023, plans include transferring sample data from SLIMS to public facing repositories (OSDR and NLSP), expanding the reach of the Chang/Blakely sample collection. The Human Research Program Space Radiation Element plans to transfer non-human tissues from many more investigations to NBISC in the coming year.

Biospecimen↗

Overview of the Digitization Workflow Post Image Acquisition of Apollo Lunar and Antarctic Meteorite Samples Using Agisoft Photoscan for the NASA 3D Astromaterials Virtual Samples Collection

The 3D Virtual Astromaterials Samples (3DVAS) collection is a multi-year funded project to create a digital database of sixty Apollo Lunar and Antarctic Meteorite samples following non-destructive documentation conservation protocols. After initial image processing, the photos are evaluated and processed using unique structure-from-motion photogrammetric techniques in a high performance modelling software designed to create a 3D model from 2D images: Agisoft Photoscan Pro. Agisoft Photoscan Pro uses image processing algorithms and techniques originating in computer vision to resolve 3D models for accurate and detailed visualization of a subject. The software provides a stepwise process that is tailored per model based on spatial and specular reflectance properties, for example. The process includes: photo alignment, creation of a dense point cloud, mesh, and finally texture. Photo alignment is dependent on model properties. The 3DVAS process requires a special rotation platform with calibrated photogrammetric targets, specific distance rotation protocols, and a contrasting background for alignment and scale accuracy. As a result of the photographic process, alignment will complete with two mirrored hemispheres that, in a sense, represent the 2D images overlapping to create a 3D model. Each dense point cloud is analyzed with provided statistical measures in a gradual selection process to eliminate outliers. The point cloud is reduced to include only data valuable to the final model. When a precise dense point cloud is achieved, a mesh and texture are applied. Each model is scaled with scale bar accuracies within 100 microns. Each sample has its own intimate process for modelling; there is no standard for the parameters required in the final creation of a high resolution model. By processing multiple samples, a skill is gained in practice to allow a close definition of the original sample and will result in the most detailed version of the sample shell. This process completes one-fifth of the 3DVAS protocol for providing accurate digital documentation. Each model shell is merged with X-ray Computed Tomography data to create a full volumetric sample. All 3DVAS data will be served on NASA's Astromaterials Acquisition and Curation website with an early subset of data available in 2019 and the 3D Virtual Astromaterials Samples Collection launch in 2020.

Thomas, Andi B.↗

Zero-G processing of magnets. Experiment MA-070

The magnetic compounds under study, manganese-bismuth (MnBi) copper-cobalt-cerium (Cu,Co)5Ce, are representative of magnetic alloy systems that have the potential for the development of high coercive strength and a high energy product. The samples of 50 at. % bismuth and 50 at. % manganese solidified in the low-g environment demonstrated a substantial improvement in the macroscopic chemical homogeneity. The bismuth/manganese-bismuth directionally solidified eutectic flight samples exhibited marked superior magnetic properties. Intrinsic coercive strengths in excess of 185 Koe have been measured in the low-g processed samples at 77 K. The average value of inductance was improved by 76 percent, and the energy product was improved by 57 percent. Additional results indicate that, in the near-absence of the gravitational body force, contained fluids will assume a lowest energy configuration that differs significantly from that found terrestrially.

Larson, D. J., Jr.↗

Mechanical properties of ion-beam-textured surgical implant alloys

An electron-bombardment Hg ion thruster was used as an ion source to texture surfaces of materials used to make orthopedic and/or dental prostheses or implants. The materials textured include 316 stainless steel, titanium-6% aluminum, 4% vanadium, and cobalt-20% chromium, 15% tungsten. To determine the effect of ion texturing on the ultimate strength and yield strength, stainless steel and Co-Cr-W alloy samples were tensile tested to failure. Three types of samples of both materials were tested. One type was ion-textured (the process also heats each sample to 300 C), another type was simply heated to 300 C in an oven, and the third type was untreated. Stress-strain diagrams, 0.2% offset yield strength data, total elongation data, and area reduction data are presented. Fatigue specimens of ion textured and untextured 316 stainless steel and Ti-6% Al-4% V were tested. Included as an ion textured sample is a Ti-6% Al-4% V sample which was ion machined by means of Ni screen mask so as to produce an array of 140 mu m x 140 mu m x 60 mu m deep pits. Scanning electron microscopy was used to characterize the ion textured surfaces.

Weigand, A. J.↗

Space Weathering in OSIRIS-REx Samples From Bennu: Impact Melt Deposits

Early analyses of regolith samples from asteroid Bennu delivered by the OSIRIS-REx spacecraft showed a mineralogy dominated by hydrated silicates, sulfides, magnetite, phosphates, and abundant organic matter, in addition to other minor/trace phases. A major objective of the sample analysis campaign is to understand the nature and extent of space weathering processes recorded by returned samples from Bennu. Here we report our preliminary transmission electron microscope (TEM) observations of impact melt deposits on surfaces of Bennu sample particles.

L. P. Keller↗

Development of Genesis Solar Wind Sample Cleanliness Assessment: Initial Report on Sample 60341 Optical Imagery and Elemental Mapping

Since 2005 the Genesis science team has experimented with techniques for removing the contaminant particles and films from the collection surface of the Genesis fragments. A subset of ~40 samples have been designated as "cleaning matrix" samples. These are small samples to which various cleaning approaches are applied and then cleanliness is assessed optically, by TRXRF, SEM, ToF-SIMS, XPS, ellipsometry or other means [1-9]. Most of these sam-ples remain available for allocation, with cleanliness assessment data. This assessment allows evaluation of various cleaning techniques and handling or analytical effects. Cleaning techniques investigated by the Genesis community include acid/base etching, acetate replica peels, ion beam, and CO2 snow jet cleaning [10-16]. JSC provides surface cleaning using UV ozone exposure and ultra-pure water (UPW) [17-20]. The UPW rinse is commonly used to clean samples for handling debris between processing by different researchers. Optical microscopic images of the sample taken before and after UPW cleaning show what has been added or removed during the cleaning process.

Gonzalez, C. P.↗

A Rapid Microfluidic Neptunium Extraction Using a Supported Liquid Membrane Module

Extraction of neptunium from acidic matrices is important for its quantification, but its complex redox chemistry can cause variable yields. This study develops a microfluidic redox extraction for rapidly separating neptunium from submilliliter samples, achieving up to 90% process yield in less than 10 min for samples as small as 100 μL, with over 97% steady-state yield achieved after 20 min. It uses a supported liquid membrane module loaded with 30 vol % tributyl phosphate in n-dodecane, which performs forward- and back-extractions in a single, continuous step. Neptunium is first oxidized to +6 for extraction and then reduced during stripping. Bromate was selected as an oxidant over permanganate for its greater compatibility with the organic phase, achieving complete oxidation in under 30 s. Ascorbic acid and hydrogen peroxide were both effective reductants. Finally, the system’s high yield and rapid kinetics make it promising for future separations from complex mixtures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Diode step stress program for JANTX1N2970b

Data for the purpose of evaluating the effect of power/temperature step stress was studied when applied to the zener diode JANTX1N2970B manufactured by Siemens and General Semiconductor, Inc. A total of 48 samples from each manufacturer was submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. The tests for determining power/temperature stresses are described, and test results are discussed. Failure analyses for power stress, and temperature stress are presented.

Source record↗

Diode step stress program for JANTX1N5615

The effect of power/temperature step stress when applied to the switching diode JANTX1N5615 manufactured by Semtech and Micro semiconductor was examined. A total of 48 samples from each manufacturer were submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. All test samples were subjected to the electrical tests after completing the prior power/temperature step stress point. Results are presented.

Source record↗

Diode step stress program for JANTX1N1202A

Power/temperature step stress was applied to the switching diode JANTX1N1202A manufactured by General Electric and International Rectifier. A total of 48 samples from each manufacturer was submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. All test samples were subjected to the electrical tests after completing the prior power/temperature step stress point. Results are given.

Source record↗

Transistor step stress program for JANTX2N2060

The effect of power/temperature step stress when applied to the dual transistor JANTX2N2060 manufactured by Raytheon and Motorola is reported. A total of 48 samples from each manufacturer were submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. All test samples were subjected to the electrical tests after completing the prior power/temperature step stress point. Results are given.

Source record↗

Diode step stress program for JANTX1N3893

Data for the purpose of evaluating the effect of power/temperature step stress on the diode JANTX1N3893 manufactured by Siemens and Motorola is presented. A total of 48 samples from each manufacturer were submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

Diode step stress testing program for JANTX1N2989B

The effect of power/temperature step stress when applied to the zener diode JANTX2N2989 manufactured by Siemens and General Semiconductor is reported. A total of 48 samples from each manufacturer was submitted to the process. In addition, two control sample units were maintained for verification of the electrical parameteric testing.

Source record↗