Search NASA⌕ Search

SEARCH · Search NASA

Results for “Total Ionizing Dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Micron MT29F128G08AJAAA 128GB Asynchronous Flash Memory Total Ionizing Dose Characterization Test Report

The purpose of this test was to characterize the Micron MT29F128G08AJAAAs parameter degradation for total dose response and to evaluate and compare lot date codes for sensitivity. In the test, the device was exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits and overall chip and die health were investigated to determine which lot is more robust.

Flash Memory↗

Si5345, SY88422L, LT3482, and MSK130 components Total Ionizing Dose Test Report

The purpose of this test was to characterize the SI-5345, SY88422L, LT3482 and MSK130 parameter degradation for total dose response. The components are associated with REAG ID #21-024. In the test, each device was exposed to high dose rate (HDR) irradiation using gamma radiation. Device parameters such as leakage currents, timing, and overall chip health were investigated. These devices were tested for an interstellar mission on a trajectory between 0.9 AU and 5.3 AU with a 2.5-year mission, yielding an expected overall dose of 29 krad(Si)behind 1 mm of aluminum shielding (at 95% confidence; environment and dose determined through SPENVIS). This test report gives an initial look at candidate parts. Extremely small sample sizes (only 1 or 2 devices tested) do not allow consideration of part-to-part variability. High dose rates were used despite LT3482 and MSK130 having potential enhanced low dose rate sensitivity (ELDRS). Care should be taken in interpreting results given these limitations.

Total Ionizing Dose (TID)↗

Total Ionizing Dose Test Report BFR92A NPN 5 GHz Wide Band Transistor from NXP

The purpose of this test was to characterize the Philips/NXP BFR92A NPN 5 gigahertz wide band silicon transistor for total dose response. This test shall serves as the radiation lot acceptance test (RLAT) for the lot date code (LDC) 1027. The BFR92A is packaged in a 3-pin plastic SOT23 package. Low dose rate (LDR/ELDRS) irradiations was performed.

Total Ionizing Dose (TID)↗

Analog Devices ADXL354 Low Noise, Low Drift, Low Power, 3-Axis MEMS Accelerometer Total Ionizing Dose Characterization Test Report

The purpose of this test was to characterize the Analog Devices ADXL354 parameter degradation for total dose response. In the test, the device was exposed to a dose rate of 50 rad(Si)/s or 0.5 Gy(Si)/s using a gamma radiation source in accordance with MIL-STD-883K Paragraph 3.6.1 (Condition A). Device parameters such as supply current, self-test voltage response, and LDO regulator output voltages were monitored.

Total Ionizing Dose (TID)↗

ISSI IS46DR16640B-25DBA25 DDR2 SDRAM Total Ionizing Dose Characterization Test Report

The purpose of this testing is to characterize the ISSI IS46DR16640B-25DBA25 parameter degradation for total dose response. This test’s purpose is to evaluate and compare lot date codes for sensitivity. In the test, the device is exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits or addresses, and overall chip and die health are investigated to determine which lot is more robust. These parameters directly affect the functionality of the memory within a system and may determine thresholds necessary to mitigate failure.

Total Ionizing Dose (TID)↗

HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test Report

The purpose of this test was to validate the Intersil HSYE-117RH-Q flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for the flight lot date with wafer lot number G3X3CQC and lot date code (LDC) 1830. Low dose rate (LDR) irradiations have been performed by the manufacturer, but only to 100 krad(Si). This test determined the enhanced low dose rate sensitivity (ELDRS) of the device up to the mission specific dose of 125 krad(Si).

Total Ionizing Dose (TID)↗

Total Ionizing Dose Effects on Voltage-to-Frequency Converters

This paper discusses total dose effects on voltage-to-frequency converters which impose different requirements on internal circuitry, and are also very high-precision devices (for example, linearity is typically specified between 0.002 and 0.05%).

low dose rate (LDR) Voltage-to-Frequency Converter↗

AD620SQ/883B Total Ionizing Dose Radiation Lot Acceptance Report for RESTORE-LEO

A Radiation Lot Acceptance Test was performed on the AD620SQ/883B, Lot 1708D, in accordance with MIL-STD-883, Method 1019, Condition D. Using a Co-60 source 4 biased parts and 4 unbiased parts were irradiated at 10 mrad/s (0.036 krad/hr) in intervals of approximately 1 krad from 3-10 krads, and ones of 5 krads from 10-25 krads, where it was annealed while unbiased at 25 degrees Celsius, for 2 days, and then, subsequently, annealed while biased at 25 degrees celsius, for another 7 days.

Bipolar↗

HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test Report

The purpose of this test was to validate the Intersil HSYE-117RH-Q flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for the flight lot date with wafer lot number G3X3CQC and lot date code (LDC) 1830. Low dose rate (LDR) irradiations have been performed by the manufacturer, but only to 100 krad(Si). This test was a follow-on to the original Radiation Lot-Specific Acceptance Testing (RLAT) performed on this LDC. Application-specific load currents were used for the line regulation and load regulation measurements. All other parameters were measured with standard bias conditions as specified in the datasheet.

Total Ionizing Dose (TID)↗

Total-Ionizing-Dose Effects on Long-term Data Retention Characteristics of Commercial 3-D NAND Memories

This article evaluates the data retention characteristics of irradiated multi-level cell (MLC) 3-D NAND flash memories. We irradiate the memory chips by a Co-60 gamma-ray source for up to 50 krad(Si) and then write a random data pattern on the irradiated chip to find its retention characteristics. The experimental results show that the data retention property of the irradiated chips is significantly degraded compared to the un-irradiated ones. We evaluate two independent strategies to improve the data retention characteristics of the irradiated chips. Furthermore, the first method involves high-temperature annealing of the irradiated chip while the second method suggests pre-programming the memory modules before deploying them in radiation-prone environments.

3-D NAND flash↗

Total Ionizing Dose Effects on High Resolution (12-/14-bit) Analog-to-Digital Converters

This paper reports total dose radiation test results for high resolution 12-/14-bit A/D converters. Small changes in internal components can cause these devices to fail their specifications at relatively low total dose levels. Degradation of signal-to-noise ratio becomes increasingly importamt for high accuracy converters. Rebound effects in the thick-oxide MOS devices causes these responses to be different at low and high dose rates, which is a major concern for space applications.

radiation ionizing analog-to-digital converters MO↗

Total Ionizing Dose Effects on 64Mb 3.3V DRAMs

64Mb 3.3V CMOS DRAMs from two different manufacturers were tested for total dose. Retention time, power supply current, and functionality were used to characterize device response.

Ionizing Dose Effects Samsung Mitsubishi↗

OMH3075 Hall Effect Sensor Total Ionizing Dose Test Report

The purpose of this test was to characterize the OMH3075 Hall Effects sensor degradation for total dose response. The device samples were exposed to low dose irradiations using gamma radiation. Device parameters such as magnetic operating points, leakage currents, supply currents, and rise and fall times were investigated.

Forney, James↗

MT29F512G08AUCBBH8-6IT:B NAND Flash Memory Total Ionizing Dose Test Report

The purpose of this test was to characterize the Micron 512 GB NAND (MT29F512G08AUCBBH8-6IT:B) flash memory parameter degradation for total dose response. In the test, the device was exposed to high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits and overall chip and die health were investigated.

TID↗

Analytical models for total dose ionization effects in MOS devices.

MOS devices are susceptible to damage by ionizing radiation due to charge buildup in gate, field and SOI buried oxides. Under positive bias holes created in the gate oxide will transport to the Si / SiO{sub 2} interface creating oxide-trapped charge. As a result of hole transport and trapping, hydrogen is liberated in the oxide which can create interface-trapped charge. The trapped charge will affect the threshold voltage and degrade the channel mobility. Neutralization of oxidetrapped charge by electron tunneling from the silicon and by thermal emission can take place over long periods of time. Neutralization of interface-trapped charge is not observed at room temperature. Analytical models are developed that account for the principal effects of total dose in MOS devices under different gate bias. The intent is to obtain closed-form solutions that can be used in circuit simulation. Expressions are derived for the aging effects of very low dose rate radiation over long time periods.

08 HYDROGEN↗

Impact of total ionizing dose irradiation on electrical property of ferroelectric-gate field-effect transistor

P-type channel metal-ferroelectric-insulator-silicon field-effect transistors (FETs) with a 300 nm thick SrBi{sub 2}Ta{sub 2}O{sub 9} ferroelectric film and a 10 nm thick HfTaO layer on silicon substrate were fabricated and characterized. The prepared FeFETs were then subjected to {sup 60}Co gamma irradiation in steps of three dose levels. Irradiation-induced degradation on electrical characteristics of the fabricated FeFETs was observed after 1 week annealing at room temperature. The possible irradiation-induced degradation mechanisms were discussed and simulated. All the irradiation experiment results indicated that the stability and reliability of the fabricated FeFETs for nonvolatile memory applications will become uncontrollable under strong irradiation dose and/or long irradiation time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗